2 resultados para wide area measurement system (WAMS)

em Repositório Institucional da Universidade Tecnológica Federal do Paraná (RIUT)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electric power systems are getting more complex and covering larger areas day by day. This fact has been contribuiting to the development of monitoring techniques that aim to help the analysis, control and planning of power systems. Supervisory Control and Data Acquisition (SCADA) systems, Wide Area Measurement Systems and disturbance record systems. Unlike SCADA and WAMS, disturbance record systems are mainly used for offilne analysis in occurrences where a fault resulted in tripping of and apparatus such as a transimission line, transformer, generator and so on. The device responsible for record the disturbances is called Digital Fault Recorder (DFR) and records, basically, electrical quantities as voltage and currents and also, records digital information from protection system devices. Generally, in power plants, all the DFRs data are centralized in the utility data centre and it results in an excess of data that difficults the task of analysis by the specialist engineers. This dissertation shows a new methodology for automated analysis of disturbances in power plants. A fuzzy reasoning system is proposed to deal with the data from the DFRs. The objective of the system is to help the engineer resposnible for the analysis of the DFRs’s information by means of a pre-classification of data. For that, the fuzzy system is responsible for generating unit operational state diagnosis and fault classification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the development and modification of techniques to reduce the effects of load variation and mains frequency deviation in repetitive controllers applied to active power filters. To minimize the effects of aperiodic signals resulting from the connection or disconnection of non-linear loads is developed a technique which recognizes linear and nonlinear loads, and operates to reset the controller only when the error due to the transition of considerable value, and the transition is from non-linear to linear load. An algorithm to adapt the gain of the repetitive controller, based on a sigmoid function adaptation, in order to minimize the effects caused by random noise in the measurement system is also used. This work also analyzes the effects of frequency variation and presents the main methods to cope with this situation. Some solutions are the change in the number of samples per period and the variation of the sampling rate. The first has the advantage of using linear design techniques and results in a time invariant system. The second method changes the sampling frequency and leads to a time variant system that demands a difficult analysis of stability. The proposed algorithms were tested using the methods of truncation of the number of samples and the method of changing the sampling rate of the system to compensate possible frequency variations of the grid. Experimental results are presented to validate the proposal.