2 resultados para refletância difusa
em Repositório Institucional da Universidade Tecnológica Federal do Paraná (RIUT)
Resumo:
This study aimed to determine the concentration and inorganic chemical composition of samples from airborne particulate matter inhaled in fine and coarse fractions. Aerosol samples were collected in 2013 and 2014, from sites located in the cities of Londrina and Maringa, in the state of Paraná, Brazil. The samples were collected daily (24h) in two campaigns: winter and summer. For the collection, was used a dichotomous sampler with quartz fiber filter with 47 mm in size and 2 µm porosity, 97% efficiency, retaining particles of up to 0.3 µm. Quantification of the airborne particulate matter mass was performed by gravimetry method. The results from Londrina to PM2.5 and MP2,5-10 represent, respectively, 29.2% and 70.8% of airborne particulate matter in the winter campaign (2013), 30.9% (PM2.5) and 69.1 % (MP2,5-10) in the summer campaign (2013), and 35.9% (PM2.5) and 64.1% (MP2,5-10) in the winter 2014 campaign. In the city of Maringa, the results presented the percentage of 42.0% (PM2.5) and 58.0% (MP2,5-10) for the winter season (2014), and 28.8% (PM2.5) and 71.2 % (MP2,5-10) for the summer season (2014). The PM2.5/PM10 ratio was on average 0.3, demonstrating that both cities are developing urban areas. Analysis of the major soluble inorganic species in water (NO3-, SO42- and Cl-) associated with MP2,5-10 were quantified by ion chromatography at the LACA Laboratory in the State University of Londrina, with the largest contribution found in all campaigns was to NO3-. The NO3-/SO42- ratios above 1.0 indicate the local traffic contribution. The analysis of metals associated with PM2.5 was carried out by mass spectrometry with inductively coupled plasma (ICP-MS) in the Federal University of Santa Catarina. The Zn, Pb, Cu and Mn concentrations found in all campaigns indicate the contribution of mobile sources to PM2.5. The concentration of BCe in PM2.5 was determined by reflectance, with higher BCe concentrations being found in winter campaigns. In general, Londrina presented the highest concentrations from the species analyzed when compared to Maringá. In addition, the analysis of the air mass trajectories indicated the transportation of pollutants coming mainly from fires in the southeastern region of the country.
Resumo:
The electric power systems are getting more complex and covering larger areas day by day. This fact has been contribuiting to the development of monitoring techniques that aim to help the analysis, control and planning of power systems. Supervisory Control and Data Acquisition (SCADA) systems, Wide Area Measurement Systems and disturbance record systems. Unlike SCADA and WAMS, disturbance record systems are mainly used for offilne analysis in occurrences where a fault resulted in tripping of and apparatus such as a transimission line, transformer, generator and so on. The device responsible for record the disturbances is called Digital Fault Recorder (DFR) and records, basically, electrical quantities as voltage and currents and also, records digital information from protection system devices. Generally, in power plants, all the DFRs data are centralized in the utility data centre and it results in an excess of data that difficults the task of analysis by the specialist engineers. This dissertation shows a new methodology for automated analysis of disturbances in power plants. A fuzzy reasoning system is proposed to deal with the data from the DFRs. The objective of the system is to help the engineer resposnible for the analysis of the DFRs’s information by means of a pre-classification of data. For that, the fuzzy system is responsible for generating unit operational state diagnosis and fault classification.