7 resultados para efluente de fecularia

em Repositório Institucional da Universidade Tecnológica Federal do Paraná (RIUT)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trinitrotoluene in the purification step (TNT) produced in industries, are carried out two washes at the end of the process. The first wash is done with vaporized water, which originates from the first effluent called yellow water, then the second washing with the use of sodium sulfite is performed (Na2SO3), generating a second effluent red water. This study aimed to study the individual effects, as well as the association of heterogeneous photocatalysis using TiO2 and biological treatment in air lift reactor using activated sludge (bacterial biomass) for the remediation of wastewater contaminated with nitroaromatic compounds in order to reduce toxicity and adjust the legal parameters according to regulatory agencies for disposal in waterways. The photocatalytic treatment was conducted by factorial design obtaining the best reaction conditions (pH 6.5 and concentration of TiO2 0.1 gL-1), with best results obtained at 360 minutes of reaction, reducing the absorbance 97.00%, 94.20% of the chemical oxygen demand (COD), 67.70% of total phenols, as well as a total reduction of observed peaks and assigned to nitroaromatic compounds by high-performance liquid chromatography. In the biological treatment, there was a 53.40% reduction in absorbance at 275 nm 10.00% 36.00% COD and total phenols in a short time (3 days), while for extended periods (48 days) there was an antagonistic influence on the results so that was the elevation of these parameters (COD and total phenols) instead of reducing. Chromatographic analysis confirmed the effectiveness of the biological degradation by reducing the peaks corresponding to compounds DNT and TNT. The Association of photocatalytic and biological treatments decreased results in the order of 91.10% absorbance, 70.26% of total phenols and 88.87% of COD. While the combination of biological and photocatalytic treatments generated relatively lower efficiencies, with 77.30% of absorbance reduction, 62.10% reduction of total phenols and a decrease of 87.00% of COD. In general, when comparing the chemical and biological processes in isolation, the photocatalytic treatment showed the best results. However, comparing the results of isolation and established associations, the association biological x photocatalysis showed more promising results in the treatment of red water effluent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main issues related to water conservation in urban centers are the increase in water supply cost, demand growth, pollution and differences in the distribution of water resources. Water conservation, the controlled and efficient use of water, includes both measures as reasonable means of water reuse. Thus, conservation practices are an effective way to meet demand and supply water to new activities and users without jeopardizing the supplying water bodies and preserving the natural environment. This study aims to examine the water management of a shopping mall and the use of rainwater harvesting combined with greywater reuse. For buildings in general, water loss is common due to leaks in the hydraulic and restroom equipment. These losses, which are caused by a high volume of water used and wasted in the system, are often the result of design errors, incorrect maintenance procedures and users' bad habits In southern Brazil, where there is rainfall almost all year long, water shortages occasionally occur, particularly in some winter mouths. One difficulty that appears on rainwater studies is the proper determination of rainwater volume that can be used to address water supply systems. In this work, the simulation method was used to determine this volume. Thus, simulations with the following variables: rainfall, catchment area and water consumption were performed. For mall's hydraulic systems, segmented alternatives are adopted. That is, focusing on the use of rainwater or greywater reuse. Other alternatives of effluent reuse have been slightly discussed due to sanitary issues, those are effluents from toilets and kitchen sinks. The adoption of greywater may be feasible if there is a significant flow of greywater to comply water demand for toilet flushing. The inspections made in this study found that the quantity of sinks was insufficient to supply an adequate amount of water to toilets and urinals. The greywater reuse system was found to be infeasible in terms of demand and supply of water. Conversely, the rainwater harvesting system was entirely feasible and easily supplied water to all restrooms and contributed to the cooling of the air conditioning system with a short payback period. One of the challenges of this work was the need to compare the actual water consumption with a water consumption parameter used in buildings. Thus, a method that addresses the generation of specific consumption indexes for specific activity (like a mall) was used. The water consumption indices showed that this mall has a satisfactory water management program.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The release of nitrogen compounds in water bodies can result in many environmental problems, so treat wastewater, such as sewage in order to remove not only organic matter but also nitrogen has been studied a few decades. From the above, the objective of this study was to evaluate the performance of a structured bed reactor, continuous flow, with recirculation, in removing organic matter and nitrogen present in wastewater under different cycles of intermittent aeration (AI) and to evaluate the influence of these cycles in the development of nitrifying bacteria (Oxidizing Bacteria Ammonia - BOA and Bacteria Oxidizing Nitrite - BON) and denitrifying (DESN) adhered (Support Material - MS) and suspension (Effluent - EF and sludge - LD). The reactor used has usable volume of 9.4 L. As support materials (MS) polyurethane foam was used, cut and fixed in PVC rods. 3 were worked aeration phases (AE) and non-aeration (AN) at different stage: Stage 1 (4 h EA / AN 2H); Stage 2 (2H EA / AN 1 h) and Phase 3 (2H EA / AN 2 h). During all hydraulic detention time phases was kept at 16 h and the effluent recirculated at a rate of 3 times the inflow. Were analyzed: pH, total alkalinity, temperature, chemical oxygen demand (COD), Biochemical Oxygen Demand (BOD), nitrogen Kjeldhl Total (NKT), ammonia-N-N-NH4+, nitrito-N-NO2+andnitrato-NO3-. The concentration of BOA, BON and DESN was determined using the number More Provável.gSSV-1 (NMP.gSSV-1). In phase 1 the percentage removal NTK N-NH4+ and NT was 76±10%, 70±21% and 67±10% respectively. In Phase 2 80±15% of removel NKT, 86±15% of N-NH4+ e 68±9% of removel NT e na Fase 3 de 58±20%, 72±28% and 41±6% of NKT, N-NH4+ of NT, respectively. The denitrification efficiency in stage 3 was over 70%, indicating that occurred in the reactor the process of simultaneous nitrification and denitrification (NDS). DQOT the removal percentages were 88 ± 4% in Phase 1, 94 ± 7 in Phase 2 and 90± 11% in Phase 3. The multivariate ANOVA applied to NMP.gSSV-1, it indicated that there was significant (F: 20,2, p <0,01) between the analyzed concentration of organisms AI in different cycles, but the differences between NMP.gSSV-1 depends not only isolated factors but of which means, and phase groups being analysis. From the results it is concluded that the working system is efficient in terms of nitrogen removal and organic matter, and that the stage with the highest availability of Dissolved Oxygen (DO) and C/N ratio (Step 2), was the one obtained the lower concentrations of organic matter effluents and N-NH4+. Hinted that there was a significant difference between the concentration (NMP.100mL-1) of the analyzed organizations (BOA, BON and DESN), but this difference does not depend on factors alone but of which means (MS, EF or LD), stages (1, 2 or 3) and groups (BOA, BON and DESN) is being considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the biggest environmental problems of the population is the lack of sewage treatment, especially in rural communities and low-income. The development of technologies for efficient, low-cost sanitation need to be developed to meet the disadvantaged people of this basic service. This work was the implementation proposal of a technology called constructed wetlands, also known as Wastewater Treatment Plant for Roots Zone - ETEZR. The objective was to develop a non- formal environmental education proposal for redevelopment, using outreach methods for residents and deployment of this technology ETEZR in the rural community of Cologne Grebe in Sao Jose dos Pinhais - PR. With technical support from the Paranaense Technical Assistance and Rural Extension Institute -EMATER and the Federal Technological University of Paraná - UTFPR, 5 ETEZR were deployed in the colony through three theoretical and practical workshops, which involved total 67 people from the community 5 technicians EMATER and 13 of the Municipal Town Hall. Após4 months of implementation were carried out two collections of raw wastewater and treated to analyze physical, chemical and biological parameters. The results evaluated by chemical parameters BOD, COD, phosphorus, ammonia nitrogen comparing raw and treated sewage, demonstrate that ETEZR are effective in the treatment of sewage. 5 Seasons minimum and maximum efficiency between the basic parameters analyzed were 52.2 to 95.5% for BOD; 47 to 94.5% for COD; 21.5 to 96% phosphorus; 30-98% for ammonia nitrogen. Oils and greases, and a series of solid also achieved a significant reduction in their values when comparing the raw sewage and treated sewage, and biological parameters evaluated by means of coliforms showed a reduction of 80 to 99%. With the implementation of environmental education process aimed sanitation was possible to evaluate the perception of the population to accept the environmental sanitation technology using the ETEZR, understand the needs and sanitation concepts for the community. This research evaluated the development of the methodology applied by the non-formal environmental education in order to provide subsidies for rural sanitation plan process for the municipality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The environmental pollution caused by industries has increased the concentration of pollutants in the environment, especially in water. Among the most diverse contaminants, there is the metals, who may or may not to be heavy/toxic, causing effluent of difficult treatment when in low concentrations. The search for alternative measures of wastewater effluent treatment has led to studies using phytoremediation technique through the various matrices (plant, fungi, bacteria) as means of polishing treatment to remove contaminants by means of biosorption/bioaccumulation. In order to use the phytoremediation technique for removing metals of the environmental, it have been performed bioassay with the macrophyte Pistia stratiotes. The bioassays were realized with healthy plants of P. stratiotes acclimatized in a greenhouse, at room temperature and lighting conditions during 28 days of cultivate. The cultivations were performed in glass vessels containing 1 L of the hydroponic solution with chromium (VI) in the potassium dichromate form with concentration range 0.10 to 4.90 mg L-1. The experiments were performed by Outlining Central Composite Rotational (OCCR), where the kinetics of bioaccumulation and chlorophyll a fluorescence were monitored in plants of P. stratiotes during cultivation. The collections of the samples and cultive solution were performed according to the OCCR. The chromium levels were measured in samples of P. stratiotes and the remaining solutions by the methodology of atomic absorption spectrometry by flame. The tolerance of P. stratiotes in relation to exposure to chromium (VI) was analyzed by parameters of physiological activity by means of chlorophyll a fluorescence, using the portable fluorometer PAM (Pulse Amplitude Modulation). The development of P. stratiots and their biomass were related to the time factor, while bioaccumulation capacities were strongly influenced by factors of time and chromium concentration (VI). The chlorophyll fluorescence parameters were affected by chromium and the exposure time at the bioassays. It was obtained an higher metal removal from the root in relation to the sheet, reaching a high rate of metal removal in solution. The experimental data removal kinetics were represented by kinetic models Irreversibly Langmuir, Reversible Langmuir, Pseudo-first Order and Pseudo-second Order, and the best fit for the culture solution was the Reversible Langmuir model with R² 0.993 and for the plant the best model was Pseudo-second order with R² 0.760.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The textile industry generates a large volume of high organic effluent loading whoseintense color arises from residual dyes. Due to the environmental implications caused by this category of contaminant there is a permanent search for methods to remove these compounds from industrial waste waters. The adsorption alternative is one of the most efficient ways for such a purpose of sequestering/remediation and the use of inexpensive materials such as agricultural residues (e.g., sugarcane bagasse) and cotton dust waste (CDW) from weaving in their natural or chemically modified forms. The inclusion of quaternary amino groups (DEAE+) and methylcarboxylic (CM-) in the CDW cellulosic structure generates an ion exchange capacity in these formerly inert matrix and, consequently, consolidates its ability for electrovalent adsorption of residual textile dyes. The obtained ionic matrices were evaluated for pHpcz, the retention efficiency for various textile dyes in different experimental conditions, such as initial concentration , temperature, contact time in order to determine the kinetic and thermodynamic parameters of adsorption in batch, turning comprehensive how does occur the process, then understood from the respective isotherms. It was observed a change in the pHpcz for CM--CDW (6.07) and DEAE+-CDW (9.66) as compared to the native CDW (6.46), confirming changes in the total surface charge. The ionized matrices were effective for removing all evaluated pure or residual textile dyes under various tested experimental conditions. The kinetics of the adsorption process data had best fitted to the model a pseudosecond order and an intraparticle diffusion model suggested that the process takes place in more than one step. The time required for the system to reach equilibrium varied according to the initial concentration of dye, being faster in diluted solutions. The isotherm model of Langmuir was the best fit to the experimental data. The maximum adsorption capacity varied differently for each tested dye and it is closely related to the interaction adsorbent/adsorbate and dye chemical structure. Few dyes obtained a linear variation of the balance ka constant due to the inversion of temperature and might have influence form their thermodynamic behavior. Dyes that could be evaluated such as BR 18: 1 and AzL, showed features of an endothermic adsorption process (ΔH° positive) and the dye VmL presented exothermic process characteristics (ΔH° negative). ΔG° values suggested that adsorption occurred spontaneously, except for the BY 28 dye, and the values of ΔH° indicated that adsorption occurred by a chemisorption process. The reduction of 31 to 51% in the biodegradability of the matrix after the dye adsorption means that they must go through a cleaning process before being discarded or recycled, and the regeneration test indicates that matrices can be reused up to five times without loss of performance. The DEAE+-CDW matrix was efficient for the removal of color from a real textile effluent reaching an UV-Visible spectral area decrease of 93% when applied in a proportion of 15 g ion exchanger matrix L-1 of colored wastewater, even in the case of the parallel presence of 50 g L-1 of mordant salts in the waste water. The wide range of colored matter removal by the synthesized matrices varied from 40.27 to 98.65 mg g-1 of ionized matrix, obviously depending in each particular chemical structure of the dye upon adsorption.