4 resultados para Unidades Haugh

em Repositório Institucional da Universidade Tecnológica Federal do Paraná (RIUT)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electric power systems are getting more complex and covering larger areas day by day. This fact has been contribuiting to the development of monitoring techniques that aim to help the analysis, control and planning of power systems. Supervisory Control and Data Acquisition (SCADA) systems, Wide Area Measurement Systems and disturbance record systems. Unlike SCADA and WAMS, disturbance record systems are mainly used for offilne analysis in occurrences where a fault resulted in tripping of and apparatus such as a transimission line, transformer, generator and so on. The device responsible for record the disturbances is called Digital Fault Recorder (DFR) and records, basically, electrical quantities as voltage and currents and also, records digital information from protection system devices. Generally, in power plants, all the DFRs data are centralized in the utility data centre and it results in an excess of data that difficults the task of analysis by the specialist engineers. This dissertation shows a new methodology for automated analysis of disturbances in power plants. A fuzzy reasoning system is proposed to deal with the data from the DFRs. The objective of the system is to help the engineer resposnible for the analysis of the DFRs’s information by means of a pre-classification of data. For that, the fuzzy system is responsible for generating unit operational state diagnosis and fault classification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The focus of this work is the automatic analysis of disturbance records for electrical power generating units. The main proposition is a method based on wavelet transform applied to short-term disturbance records (waveform records). The goal of the method is to detect the time instants of recorded disturbances and extract meaningful information that characterize the faults. The result is a set of representative information of the monitored signals in power generators. This information can be further classified by an expert system (or other classification method) in order to classify the faults and other abnormal operating conditions. The large amount of data produced by digital fault recorders during faults justify the research of methods to assist the analysts in their task of analysing the disturbances. The literature review pointed out the state of the art and possible applications for oscillography records. The review of the COMTRADE standard and wavelet transform underlines the choice of the method for solving the problem. The conducted tests lead to the determination of the best mother wavelet for the segmentation process. The application of the proposed method to five case studies with real oscillographic records confirmed the accuracy and efficiency of the proposed scheme. With this research, the post-operation analysis of occurrences is improved and as a direct result is the reduction of the time that generators are offline.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a low cost architecture for development of synchronized phasor measurement units (PMU). The device is intended to be connected in the low voltage grid, which allows the monitoring of transmission and distribution networks. Developments of this project include a complete PMU, with instrumentation module for use in low voltage network, GPS module to provide the sync signal and time stamp for the measures, processing unit with the acquisition system, phasor estimation and formatting data according to the standard and finally, communication module for data transmission. For the development and evaluation of the performance of this PMU, it was developed a set of applications in LabVIEW environment with specific features that let analyze the behavior of the measures and identify the sources of error of the PMU, as well as to apply all the tests proposed by the standard. The first application, useful for the development of instrumentation, consists of a function generator integrated with an oscilloscope, which allows the generation and acquisition of signals synchronously, in addition to the handling of samples. The second and main, is the test platform, with capabality of generating all tests provided by the synchronized phasor measurement standard IEEE C37.118.1, allowing store data or make the analysis of the measurements in real time. Finally, a third application was developed to evaluate the results of the tests and generate calibration curves to adjust the PMU. The results include all the tests proposed by synchrophasors standard and an additional test that evaluates the impact of noise. Moreover, through two prototypes connected to the electrical installation of consumers in same distribution circuit, it was obtained monitoring records that allowed the identification of loads in consumer and power quality analysis, beyond the event detection at the distribution and transmission levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over time, humanity began to realize the negative impact that the modern world has caused to the environment. The Atlantic Forest is one of the richest biomes in biodiversity, covering more than 60% of all species on the planet. This biome covered about 15% of the Brazilian territory, leaving currently only 7% of its fully fragmented forest remnants. This was the biome that suffered most from modernization and strong anthropogenic pressures in Brazil. For the account of environmental degradation, in the second half of the nineteenth century there was a shift in thinking, giving greater emphasis on conservation of some natural landscapes, with the intention of removing the man still preserved nature. Based on American models of conservation there were created the Nature Conservation Units. This study aimed to analyze the environmental quality of the State Park Vitório Piassa, a Conservation Unit located in the city of Pato Branco - PR. The environmental quality was measured by use of bio-indicators and some environmental pressures that the Park has suffered over the years also were identified. Beetles of the familiy Scarabaeinae (Coleoptera: Scarabaeidae) were used as the bioindicators. To compare the most conserved areas and the most degraded areas of the Park, three specific sites were defined within the Atlantic Forest fragment, these insects were captured with pitfall traps and identified as to their species and genera. There were two collections in February and March 2015, which resulted in 945 individuals in 22 species and nine different genus. Then the population of beetles in each area were classified based on ecological measures such as species richness, abundance of individuals of each species through diversity index (Shannon and Simpson) to identify the differences between the sampled groups and equitability (Pielou) to measure the distribution of the total abundance of the species in each area. To meet the objective of identifying the environmental pressures that occur in PEVP, evidence were collected through photographs, watching the field, aerial images and conversations with the resident population in the park. Similarly, if made relevant to build on the project running by the municipality for the construction of infrastructure for public viewing. These data served as subsidies to confront the current situation of the park and the current Brazilian legislation for UC's of full protection, highlighting the existing socio-environmental conflicts in the park, involving political issues and the proximity of the Conservation Unit with the urban area of the city.