3 resultados para Refinery effluents

em Repositório Institucional da Universidade Tecnológica Federal do Paraná (RIUT)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main aim of this study was to evaluate the impact of the urban pollution plume from the city of Manaus by emissions from mobile and stationary sources in the atmospheric pollutants concentrations of the Amazon region, by using The Weather Research and Forecasting with Chemistry (WRF-Chem) model. The air pollutants analyzed were CO, NOx, SO2, O3, PM2.5, PM10 and VOCs. The model simulations have been configured with a grid spacing of 3 km, with 190 x and 136 y grid points in horizontal spacing, centered in the city of Manaus during the period of 17 and 18 of March 2014. The anthropogenic emissions inventories have gathered from mobile sources that were estimated the emissions of light and heavy-duty vehicles classes. In addition, the stationary sources have considered the thermal power plants by the type of energy sources used in the region as well as the emissions from the refinery located in Manaus. Various scenarios have been defined with numerical experiments that considered only emissions by biogenic, mobile and stationary sources, and replacement fuel from thermal power plant, along with a future scenario consisting with twice as much anthropogenic emissions. A qualitative assessment of simulation with base scenario has also been carried out, which represents the conditions of the region in its current state, where several statistical methods were used in order to compare the results of air pollutants and meteorological fields with observed ground-based data located in various points in the study grid. The qualitative analysis showed that the model represents satisfactorily the variables analyzed from the point of view of the adopted parameters. Regarding the simulations, defined from the base scenarios, the numerical experiments indicate relevant results such as: it was found that the stationary sources scenario, where the thermal power plants are predominant, resulted in the highest concentrations, for all air pollutants evaluated, except for carbon monoxide when compared to the vehicle emissions scenario; The replacement of the energy matrix of current thermal power plants for natural gas have showed significant reductions in pollutants analyzed, for instance, 63% reductions of NOx in the contribution of average concentration in the study grid; A significant increase in the concentrations of chemical species was observed in a futuristic scenario, reaching up to a 81% increase in peak concentrations of SO2 in the study area. The spatial distributions of the scenarios have showed that the air pollution plume from Manaus is predominantly west and southwest, where it can reach hundreds of kilometers to areas dominated by original soil covering.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main issues related to water conservation in urban centers are the increase in water supply cost, demand growth, pollution and differences in the distribution of water resources. Water conservation, the controlled and efficient use of water, includes both measures as reasonable means of water reuse. Thus, conservation practices are an effective way to meet demand and supply water to new activities and users without jeopardizing the supplying water bodies and preserving the natural environment. This study aims to examine the water management of a shopping mall and the use of rainwater harvesting combined with greywater reuse. For buildings in general, water loss is common due to leaks in the hydraulic and restroom equipment. These losses, which are caused by a high volume of water used and wasted in the system, are often the result of design errors, incorrect maintenance procedures and users' bad habits In southern Brazil, where there is rainfall almost all year long, water shortages occasionally occur, particularly in some winter mouths. One difficulty that appears on rainwater studies is the proper determination of rainwater volume that can be used to address water supply systems. In this work, the simulation method was used to determine this volume. Thus, simulations with the following variables: rainfall, catchment area and water consumption were performed. For mall's hydraulic systems, segmented alternatives are adopted. That is, focusing on the use of rainwater or greywater reuse. Other alternatives of effluent reuse have been slightly discussed due to sanitary issues, those are effluents from toilets and kitchen sinks. The adoption of greywater may be feasible if there is a significant flow of greywater to comply water demand for toilet flushing. The inspections made in this study found that the quantity of sinks was insufficient to supply an adequate amount of water to toilets and urinals. The greywater reuse system was found to be infeasible in terms of demand and supply of water. Conversely, the rainwater harvesting system was entirely feasible and easily supplied water to all restrooms and contributed to the cooling of the air conditioning system with a short payback period. One of the challenges of this work was the need to compare the actual water consumption with a water consumption parameter used in buildings. Thus, a method that addresses the generation of specific consumption indexes for specific activity (like a mall) was used. The water consumption indices showed that this mall has a satisfactory water management program.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The release of nitrogen compounds in water bodies can result in many environmental problems, so treat wastewater, such as sewage in order to remove not only organic matter but also nitrogen has been studied a few decades. From the above, the objective of this study was to evaluate the performance of a structured bed reactor, continuous flow, with recirculation, in removing organic matter and nitrogen present in wastewater under different cycles of intermittent aeration (AI) and to evaluate the influence of these cycles in the development of nitrifying bacteria (Oxidizing Bacteria Ammonia - BOA and Bacteria Oxidizing Nitrite - BON) and denitrifying (DESN) adhered (Support Material - MS) and suspension (Effluent - EF and sludge - LD). The reactor used has usable volume of 9.4 L. As support materials (MS) polyurethane foam was used, cut and fixed in PVC rods. 3 were worked aeration phases (AE) and non-aeration (AN) at different stage: Stage 1 (4 h EA / AN 2H); Stage 2 (2H EA / AN 1 h) and Phase 3 (2H EA / AN 2 h). During all hydraulic detention time phases was kept at 16 h and the effluent recirculated at a rate of 3 times the inflow. Were analyzed: pH, total alkalinity, temperature, chemical oxygen demand (COD), Biochemical Oxygen Demand (BOD), nitrogen Kjeldhl Total (NKT), ammonia-N-N-NH4+, nitrito-N-NO2+andnitrato-NO3-. The concentration of BOA, BON and DESN was determined using the number More Provável.gSSV-1 (NMP.gSSV-1). In phase 1 the percentage removal NTK N-NH4+ and NT was 76±10%, 70±21% and 67±10% respectively. In Phase 2 80±15% of removel NKT, 86±15% of N-NH4+ e 68±9% of removel NT e na Fase 3 de 58±20%, 72±28% and 41±6% of NKT, N-NH4+ of NT, respectively. The denitrification efficiency in stage 3 was over 70%, indicating that occurred in the reactor the process of simultaneous nitrification and denitrification (NDS). DQOT the removal percentages were 88 ± 4% in Phase 1, 94 ± 7 in Phase 2 and 90± 11% in Phase 3. The multivariate ANOVA applied to NMP.gSSV-1, it indicated that there was significant (F: 20,2, p <0,01) between the analyzed concentration of organisms AI in different cycles, but the differences between NMP.gSSV-1 depends not only isolated factors but of which means, and phase groups being analysis. From the results it is concluded that the working system is efficient in terms of nitrogen removal and organic matter, and that the stage with the highest availability of Dissolved Oxygen (DO) and C/N ratio (Step 2), was the one obtained the lower concentrations of organic matter effluents and N-NH4+. Hinted that there was a significant difference between the concentration (NMP.100mL-1) of the analyzed organizations (BOA, BON and DESN), but this difference does not depend on factors alone but of which means (MS, EF or LD), stages (1, 2 or 3) and groups (BOA, BON and DESN) is being considered.