2 resultados para Reator químico

em Repositório Institucional da Universidade Tecnológica Federal do Paraná (RIUT)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The release of nitrogen compounds in water bodies can result in many environmental problems, so treat wastewater, such as sewage in order to remove not only organic matter but also nitrogen has been studied a few decades. From the above, the objective of this study was to evaluate the performance of a structured bed reactor, continuous flow, with recirculation, in removing organic matter and nitrogen present in wastewater under different cycles of intermittent aeration (AI) and to evaluate the influence of these cycles in the development of nitrifying bacteria (Oxidizing Bacteria Ammonia - BOA and Bacteria Oxidizing Nitrite - BON) and denitrifying (DESN) adhered (Support Material - MS) and suspension (Effluent - EF and sludge - LD). The reactor used has usable volume of 9.4 L. As support materials (MS) polyurethane foam was used, cut and fixed in PVC rods. 3 were worked aeration phases (AE) and non-aeration (AN) at different stage: Stage 1 (4 h EA / AN 2H); Stage 2 (2H EA / AN 1 h) and Phase 3 (2H EA / AN 2 h). During all hydraulic detention time phases was kept at 16 h and the effluent recirculated at a rate of 3 times the inflow. Were analyzed: pH, total alkalinity, temperature, chemical oxygen demand (COD), Biochemical Oxygen Demand (BOD), nitrogen Kjeldhl Total (NKT), ammonia-N-N-NH4+, nitrito-N-NO2+andnitrato-NO3-. The concentration of BOA, BON and DESN was determined using the number More Provável.gSSV-1 (NMP.gSSV-1). In phase 1 the percentage removal NTK N-NH4+ and NT was 76±10%, 70±21% and 67±10% respectively. In Phase 2 80±15% of removel NKT, 86±15% of N-NH4+ e 68±9% of removel NT e na Fase 3 de 58±20%, 72±28% and 41±6% of NKT, N-NH4+ of NT, respectively. The denitrification efficiency in stage 3 was over 70%, indicating that occurred in the reactor the process of simultaneous nitrification and denitrification (NDS). DQOT the removal percentages were 88 ± 4% in Phase 1, 94 ± 7 in Phase 2 and 90± 11% in Phase 3. The multivariate ANOVA applied to NMP.gSSV-1, it indicated that there was significant (F: 20,2, p <0,01) between the analyzed concentration of organisms AI in different cycles, but the differences between NMP.gSSV-1 depends not only isolated factors but of which means, and phase groups being analysis. From the results it is concluded that the working system is efficient in terms of nitrogen removal and organic matter, and that the stage with the highest availability of Dissolved Oxygen (DO) and C/N ratio (Step 2), was the one obtained the lower concentrations of organic matter effluents and N-NH4+. Hinted that there was a significant difference between the concentration (NMP.100mL-1) of the analyzed organizations (BOA, BON and DESN), but this difference does not depend on factors alone but of which means (MS, EF or LD), stages (1, 2 or 3) and groups (BOA, BON and DESN) is being considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trinitrotoluene in the purification step (TNT) produced in industries, are carried out two washes at the end of the process. The first wash is done with vaporized water, which originates from the first effluent called yellow water, then the second washing with the use of sodium sulfite is performed (Na2SO3), generating a second effluent red water. This study aimed to study the individual effects, as well as the association of heterogeneous photocatalysis using TiO2 and biological treatment in air lift reactor using activated sludge (bacterial biomass) for the remediation of wastewater contaminated with nitroaromatic compounds in order to reduce toxicity and adjust the legal parameters according to regulatory agencies for disposal in waterways. The photocatalytic treatment was conducted by factorial design obtaining the best reaction conditions (pH 6.5 and concentration of TiO2 0.1 gL-1), with best results obtained at 360 minutes of reaction, reducing the absorbance 97.00%, 94.20% of the chemical oxygen demand (COD), 67.70% of total phenols, as well as a total reduction of observed peaks and assigned to nitroaromatic compounds by high-performance liquid chromatography. In the biological treatment, there was a 53.40% reduction in absorbance at 275 nm 10.00% 36.00% COD and total phenols in a short time (3 days), while for extended periods (48 days) there was an antagonistic influence on the results so that was the elevation of these parameters (COD and total phenols) instead of reducing. Chromatographic analysis confirmed the effectiveness of the biological degradation by reducing the peaks corresponding to compounds DNT and TNT. The Association of photocatalytic and biological treatments decreased results in the order of 91.10% absorbance, 70.26% of total phenols and 88.87% of COD. While the combination of biological and photocatalytic treatments generated relatively lower efficiencies, with 77.30% of absorbance reduction, 62.10% reduction of total phenols and a decrease of 87.00% of COD. In general, when comparing the chemical and biological processes in isolation, the photocatalytic treatment showed the best results. However, comparing the results of isolation and established associations, the association biological x photocatalysis showed more promising results in the treatment of red water effluent.