4 resultados para Monitoramento térmico

em Repositório Institucional da Universidade Tecnológica Federal do Paraná (RIUT)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work aims to develop optical sensors for temperature monitoring in hydroelectric power plant heat exchangers. The proposed sensors are based on the Fiber Bragg Gratings technology. First of all, a prototype with three sensors inscribed in a same fiber was developed. This fiber was then fixed to a conventional Pt100 sensor rod and inserted in a thermowell. The ensemble was then calibrated in a workbench, presenting a maximum combined uncertainty of 2,06 °C. The sensor was installed in one of the heat exchangers of the Salto Osório’s hydroelectric power plant. This power plant is situated in the Iguaçu river, at the Paraná state. Despite the satisfactory results, the sensor was improved to a second version. In this, fifteen optical Bragg sensors were inscribed in a same fiber. The fixation with a conventional sensor was no longer necessary, because the first version results comproved the efficiency and response time in comparison to a conventional sensor. For this reason, it was decided to position the fiber inside a stainless steel rod, due to his low thermal expansion coefficient and high corrosion immunity. The utilization of fifteen fiber Bragg gratings aims to improve the sensor spatial resolution. Therefore, measurements every ten centimeters with respect to the heat exchanger’s height are possible. This provides the generation of a thermal map of the heat exchanger’s surface, which can be used for determination of possible points of obstruction in the hydraulic circuit of the heat exchanger. The heat exchanger’s obstruction in hydroelectric power plants usually occur by bio-fouling, and has direct influence in the generator’s cooling system efficiency. The obtained results have demonstrated the feasibility in application of the optical sensors technology in hydroelectric power plants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a low cost architecture for development of synchronized phasor measurement units (PMU). The device is intended to be connected in the low voltage grid, which allows the monitoring of transmission and distribution networks. Developments of this project include a complete PMU, with instrumentation module for use in low voltage network, GPS module to provide the sync signal and time stamp for the measures, processing unit with the acquisition system, phasor estimation and formatting data according to the standard and finally, communication module for data transmission. For the development and evaluation of the performance of this PMU, it was developed a set of applications in LabVIEW environment with specific features that let analyze the behavior of the measures and identify the sources of error of the PMU, as well as to apply all the tests proposed by the standard. The first application, useful for the development of instrumentation, consists of a function generator integrated with an oscilloscope, which allows the generation and acquisition of signals synchronously, in addition to the handling of samples. The second and main, is the test platform, with capabality of generating all tests provided by the synchronized phasor measurement standard IEEE C37.118.1, allowing store data or make the analysis of the measurements in real time. Finally, a third application was developed to evaluate the results of the tests and generate calibration curves to adjust the PMU. The results include all the tests proposed by synchrophasors standard and an additional test that evaluates the impact of noise. Moreover, through two prototypes connected to the electrical installation of consumers in same distribution circuit, it was obtained monitoring records that allowed the identification of loads in consumer and power quality analysis, beyond the event detection at the distribution and transmission levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chemical changes in clay minerals has been widely studied in order to improve its properties for use in various applications. However kaolinite has strong hydrogen bonds between their adjacent layers hindering the process changes in its structure. With the objective to facilitate the process of intercalation monobasic potassium phosphate, bibasic potassium phosphate and potassium acetate we was performed on kaolinite heat treatment at 600 °C and activated acidic with phosphoric acid and 5 to 10 mol L-1. The samples they were characterized by energy dispersive spectroscopy (EDS), X-Ray Diffraction (XRD), Infrared Spectroscopy Fourier Transform (FTIR) and Thermogravimetric Analysis (TG) and Differential Thermal Analysis (DTG) and the superficial and textural changes the samples with heat treatment and acid activation they were characterized by scanning electron microscopy (SEM) and Textural Analysis of Adsorption/desorption N2. With the help of the techniques found that, the heat treatment becomes more susceptible to acid activation kaolinite making the samples with two treatments show larger amounts of phosphorus. It was also found that bibasic potassium phosphate binds more strongly the structure of kaolinite by having a structure with two-coordinating oxygens and intercalation with potassium acetate in acid-activated kaolin increases the interlayer distance of the kaolinite and the intercalation occurs with higher response index (RI) for samples with acid activation to 5 mol /L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct evaporative cooling systems (DECS) based on sprinkling water indoors in the form of droplets and indirect evaporative cooling systems (IECS), characterized by the use of wetted roof or wall surfaces for cooling without increasing the indoor air moisture, consist of interesting bioclimatic strategies still not quite explored in Brazil. This study aims to evaluate the use of a particular form of IECS (which combines evaporative cooling and thermal mass brought about by a water reservoir) for indoor thermal control in warm conditions in Curitiba, Two test cells were initially built, monitored and compared to each other: a control module (CM) and an experimental module (EM), the latter provided with an evaporative pond. A subsequent configuration of the system which cancels out the evaporative function of the system and that is solely based on the increase of thermal mass, was tested in a second monitoring round. A third configuration of EM combinig evaporative cooling and the increase of termal mass was tested. Results showed a higher effectiveness of the IECS for the indoor cooling of the tested cells. The average temperature in EM was reduced in 2.5°C and the maximum temperature was reduced in 8.0°C in comparison with the CM. Results also showed a strong relation between the wet-bulb temperature depression and the internal temperature decrease achieved by the evaporative cooling strategy.