4 resultados para Medições

em Repositório Institucional da Universidade Tecnológica Federal do Paraná (RIUT)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Some quality defects can cause changes in attributes of the meat, among these we can detach the PSE meat (Pale, Soft and Exudative). The PSE meat is pale, flaccid and exudative and result from sudden pH decrease while the carcass is still under high temperature. The identification of PSE meat has been done by measuring pH and L* (Lightness). However, studies suggest that a more precise evaluation of the kinetics of pH and temperature decrease has to be conducted to better understand the etiology of PSE meat in poultry. The aim of this study was to obtain the glycolytic curve for normal and PSE meat of chicken, through the pH, L* and CRA (water holding capacity) analysis. This experiment was conducted with carcasses obtained from a commercial slaughterhouse (n = 35) of Cobb lineage, 50 days old, from the same batch of creation and with the same pre-slaughter fasting time (10h). Samples of breast fillets were obtained from carcasses randomly collected immediately at the output of pre-cooling chiller, and the analysis of pH, temperature and L * were conducted in the same in times 1h35, 2h35, 3h35, 5h35, 8h35, 11h35, 14h35, 17h35, 20h35, 23h35 and 25h35 post mortem. The CRA analyzes were performed at the time of 25h35 post mortem. The pH measurements indicated that only from the 04 time (8h35 post mortem) was possible to verify an indicative of stabilization, being that PSE meat pH was 5,69±0,07, and normal meat was 5,93±0,09. The final pH (25h35 post mortem) was 5,98±0,06 and L* 57,30± 2,39 for normal meat, while for PSE meat the result was 5,72±0,06 and L* 59,44±1,51. To CRA, the average of the samples (67,19±3.13 and 64,45± 2.66) showed a difference between the normal chicken fillets and PSE respectively. The data found in this study are consistent with those reported by own research group in another slaughterhouse and contradicts similar works, but made at room temperature, indicating that for chickens under commercial conditions the resolution of rigor mortis occurs after 8h35 post mortem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The jabuticaba tree has great potential for commercial exploitation. However, its is very little used. This fact shows to be necessary to do studies that allow understand their growth behavior during the year and, if it is tolerant to frost. So that it can establish management strategies for cultivation in orchard. Other point, it is the fact that the long juvenile period of jabuticaba tree limits its use. However, many species have compound leaves that characterize them as functional compounds, what to posible its commercialization. If the leaf jabuticaba tree also present such nutraceutical compounds, this it may become an alternative source of income until the plant to start its yield. The objectives of this study were to analyze the growth behavior, the occurrence of flowering and fruit set, and the frost tolerance of jabuticaba tree genotypes present in the collection of Native Fruit from UTFPR – Câmpus Dois Vizinhos. Associated growth analysis was made evaluation of genetic divergence among these genotypes, checking the adaptive behavior in orchard condition through adaptability and stability analysis based on growth measures to stem and shoots; estimating the repeatability coefficient of stem length of characters and primary shoots, and determine the minimum number of evaluations able to provide certain levels of prediction of the actual value of these individuals. Also determined the genetic divergence among genotypes as the leaves of antioxidant activity by DPPH and ABTS methods, as well as the determination of total phenolics. The genotypes studied were put in orchard in 2009. The growth response in the three cycles was variable between months and genotypes, what it can be difficult the practices in the orchard if it do not use clones. Genotypes 'Silvestre' and 'Açú' showed greater width and leaf area compared with other genotypes, but such behavior is not favored for increased stem growth and primary shoots. Foliar increments in most genotypes occurred in the fall for leaf width, spring for length and leaf area, despite the winter also arise with genotypes, it showed superiority to width and leaf area. Most jabuticabas trees were juvenile stage with only four starting at its transition between the vegetative and reproductive phase. Tolerance to frost was observed in 26 families jabuticabeira of the 29 present in the collection. The diversity among the genotypes was to change with the time, already in each cycle, there was the formation of different groups by the methods used. The methods tested for adaptability and stability of the jabuticaba tree growth behavior did not show the same pattern in the results. The number of measurements needed to predict the actual value of genotypes based on variables evaluated was approximately one to the stem length and four for the shoots based on the method of main components of covariance with 90% probability. he antioxidant activity of the extracts of leaves of jabuticaba tree genotypes were demonstrated high when compared to other species by methods DPPH and ABTS, as well as the amount of phenolic compounds. Genotype 'Silvestre' and 'IAPAR' showed the highest antioxidant activity in the leaves. However, the genetic divergence among genotypes jabuticaba tree from collection of Native Fruit trees at UTFPR - Câmpus Dois Vizinhos for antioxidant activity leaves showed that they have great homogeneity among them and the low divergence. However, it is recommended as possible hybridization the use as parents, José 4, IAPAR 4 and Fernando Xavier genotypes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to develop optical sensors for temperature monitoring in hydroelectric power plant heat exchangers. The proposed sensors are based on the Fiber Bragg Gratings technology. First of all, a prototype with three sensors inscribed in a same fiber was developed. This fiber was then fixed to a conventional Pt100 sensor rod and inserted in a thermowell. The ensemble was then calibrated in a workbench, presenting a maximum combined uncertainty of 2,06 °C. The sensor was installed in one of the heat exchangers of the Salto Osório’s hydroelectric power plant. This power plant is situated in the Iguaçu river, at the Paraná state. Despite the satisfactory results, the sensor was improved to a second version. In this, fifteen optical Bragg sensors were inscribed in a same fiber. The fixation with a conventional sensor was no longer necessary, because the first version results comproved the efficiency and response time in comparison to a conventional sensor. For this reason, it was decided to position the fiber inside a stainless steel rod, due to his low thermal expansion coefficient and high corrosion immunity. The utilization of fifteen fiber Bragg gratings aims to improve the sensor spatial resolution. Therefore, measurements every ten centimeters with respect to the heat exchanger’s height are possible. This provides the generation of a thermal map of the heat exchanger’s surface, which can be used for determination of possible points of obstruction in the hydraulic circuit of the heat exchanger. The heat exchanger’s obstruction in hydroelectric power plants usually occur by bio-fouling, and has direct influence in the generator’s cooling system efficiency. The obtained results have demonstrated the feasibility in application of the optical sensors technology in hydroelectric power plants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An ideal biomaterial for dental implants must have very high biocompatibility, which means that such materials should not provoke any serious adverse tissue response. Also, used metal alloys must have high fatigue resistance due the masticatory force and good corrosion resistance. These properties are rendered by using alpha and beta stabilizers, such as Al, V, Ni, Fe, Cr, Cu, Zn. Commercially pure titanium (TiCP) is used often for dental and orthopedic implants manufacturing. However, sometimes other alloys are employed and consequently it is essential to research the chemical elements present in those alloys that could bring prejudice for the health. Present work investigated TiCP metal alloys used for dental implant manufacturing and evaluated the presence of stabilizing elements within existing limits and standards for such materials. For alloy characterization and identification of stabilizing elements it was used EDXRF technique. This method allows to perform qualitative and quantitative analysis of the materials using the spectra of the characteristic X-rays emitted by the elements present in the metal samples. The experimental setup was based on two X- rays tubes (AMPTEK Mini X model with Ag and Au targets), a X-123SDD detector (AMPTEK) and a 0.5mm Cu collimator, developed due to the sample characteristics. The other experimental setup used as a complementary technique is composed of an X-ray tube with a Mo target, collimator 0.65mm and XFlash (SDD) detector - ARTAX 200 (BRUKER). Other method for elemental characterization by energy dispersive spectroscopy (EDS) applied in present work was based on Scanning Electron Microscopy (SEM) EVO® (Zeeis). This method also was used to evaluate the surface microstructure of the sample. The percentual of Ti obtained in the elementary characterization was among 93.35 ± 0.17% and 95.34 ± 0.19 %. These values are considered below the reference limit of 98.635% to 99.5% for TiCP, established by Association of metals centric materials engineers and scientists Society (ASM). The presence of elements Al and V in all samples also contributed to underpin the fact that are not TiCP implants. The values for Al vary between 6.3 ± 1.3% and 3.7 ± 2.0% and for V, between 0.26 ± 0.09% and 0.112 ± 0.048%. According to the American Society for Testing and Materials (ASTM), these elements should not be present in TiCP and in accordance with the National Institute of Standards and Technology (NIST), the presence of Al should be <0.01% and V should be of 0.009 ± 0.001%. Obtained results showed that implant materials are not exactly TiCP but, were manufactured using Ti-Al-V alloy, which contained Fe, Ni, Cu and Zn. The quantitative analysis and elementary characterization of experimental results shows that the best accuracy and precision were reached with X-Ray tube with Au target and collimator of 0.5 mm. Use of technique of EDS confirmed the results of EDXRF for Ti-Al-V alloy. Evaluating the surface microstructure by SEM of the implants, it was possible to infer that ten of the thirteen studied samples are contemporaneous, rough surface and three with machined surface.