Centrifugal pumps are vastly used in many industrial applications. Knowledge of how these components behave in several circumstances is crucial for the development of more efficient and, therefore, less expensive pumping installations. The combination of multiple impellers, vaned diffusers and a volute might introduce several complex flow characteristics that largely deviate from regular inviscid pump flow theory. Computational Fluid Dynamics can be very helpful to extract information about which physical phenomena are involved in such flows. In this sense, this work performs a numerical study of the flow in a two-stage centrifugal pump (Imbil ITAP 65-330/2) with a vaned diffuser and a volute. The flow in the pump is modeled using the software Ansys CFX, by means of a multi-block, transient rotor-stator technique, with structured grids for all pump parts. The simulations were performed using water and a mixture of water and glycerin as work fluids. Several viscosities were considered, in a range between 87 and 720 cP. Comparisons between experimental data obtained by Amaral (2007) and numerical head curves showed a good agreement, with an average deviation of 6.8% for water. The behavior of velocity, pressure and turbulence kinetic energy fields was evaluated for several operational conditions. In general, the results obtained by this work achieved the proposed goals and are a significant contribution to the understanding of the flow studied.