7 resultados para Investimentos na saúde - Modelos matemáticos

em Repositório Institucional da Universidade Tecnológica Federal do Paraná (RIUT)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reinforced concrete creep is a phenomenon of great importance. Despite being appointed as the main cause of several pathologies, its effects are yet considered in a simplified way by the structural designers. In addition to studying the phenomenon in reinforced concrete structures and its current account used in the structural analysis, this paper compares creep strains at simply supported reinforced concrete beams in analytical and in experimental forms with the finite element method (FEM) simulation results. The strains and deflections obtained through the analytical form were calculated with the Brazilian code NBR 6118 (2014) recommendations and the simplified method from CEB-FIP 90 and the experimental results were extracted from tests available in the literature. Finite element simulations are performed using ANSYS Workbench software, using its 3D SOLID 186 elements and the structure symmetry. Analyzes of convergence using 2D PLANE 183 elements are held as well. At the end, it is concluded that FEM analyses are quantitative and qualitative efficient for the estimation of this non-linearity and that the method utilized to obtain the creep coefficients values is sufficiently accurate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A significant part of the life of a mechanical component occurs, the crack propagation stage in fatigue. Currently, it is had several mathematical models to describe the crack growth behavior. These models are classified into two categories in terms of stress range amplitude: constant and variable. In general, these propagation models are formulated as an initial value problem, and from this, the evolution curve of the crack is obtained by applying a numerical method. This dissertation presented the application of the methodology "Fast Bounds Crack" for the establishment of upper and lower bounds functions for model evolution of crack size. The performance of this methodology was evaluated by the relative deviation and computational times, in relation to approximate numerical solutions obtained by the Runge-Kutta method of 4th explicit order (RK4). Has been reached a maximum relative deviation of 5.92% and the computational time was, for examples solved, 130,000 times more higher than achieved by the method RK4. Was performed yet an Engineering application in order to obtain an approximate numerical solution, from the arithmetic mean of the upper and lower bounds obtained in the methodology applied in this work, when you don’t know the law of evolution. The maximum relative error found in this application was 2.08% which proves the efficiency of the methodology "Fast Bounds Crack".

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drilling fluids present a thixotropic behavior and they usually gel when at rest. The sol-gel transition is fundamental to prevent the deposit of rock fragments, generated by drilling the well, over the drill bit during eventual stops. Under those conditions, high pressures are then required in order to break-up the gel when circulation is resumed. Moreover, very high pressures can damage the rock formation at the bottom of the well. Thus, a better understanding of thixotropy and the behavior of thixotropic materials becomes increasingly important for process control. The mechanisms that control thixotropy are not yet well defined and modeling is still a challenge. The objective of this work is to develop a mathematical model to study the pressure transmission in drilling fluids. This work presents a review of thixotropy and of different mathematical models found in the literature that are used to predict such characteristic. It also shows a review of transient flows of compressible fluids. The problem is modeled as the flow between the drillpipe and the annular region (space between the wall and the external part of the drillpipe). The equations that describe the problem (mass conservation, momentum balance, constitutive and state) are then discretized and numerically solved by using a computational algorithm in Fortran. The model is validated with experimental and numerical data obtained from the literature. Comparisons between experimental data obtained from Petrobras and calculated by three viscoplastic and one pseudoplastic models are conducted. The viscoplastic fluids, due to the yield stress, do not fully transmit the pressure to the outlet of the annular space. Sensibility analyses are then conducted in order to evaluate the thixotropic effect in pressure transmission.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Distributed generation systems must fulfill standards specifications of current harmonics injected to the grid. In order to satisfy these grid requirements, passive filters are connected between inverter and grid. This work compares the characteristic response of the traditional inductive (L) filter with the inductive-capacitive-inductive (LCL) filter. It is shown that increasing the inductance L leads to a good ripple current suppression around the inverter switching frequency. The LCL filter provides better harmonic attenuation and reduces the filter size. The main drawback is the LCL filter impedance, which is characterized by a typical resonance peak, which must be damped to avoid instability. Passive or active techniques can be used to damp the LCL resonance. To address this issue, this dissertation presents a comparison of current control for PV grid-tied inverters with L filter and LCL filter and also discuss the use of active and passive damping for different regions of resonance frequency. From the mathematical models, a design methodology of the controllers was developed and the dynamic behavior of the system operating in closed loop was investigated. To validate the studies developed during this work, experimental results are presented using a three-phase 5kW experimental platform. The main components and their functions are discussed in this work. Experimental results are given to support the theoretical analysis and to illustrate the performance of grid-connected PV inverter system. It is shown that the resonant frequency of the system, and sampling frequency can be associated in order to calculate a critical frequency, below which is essential to perform the damping of the LCL filter. Also, the experimental results show that the active buffer per virtual resistor, although with a simple development, is effective to damp the resonance of the LCL filter and allow the system to operate stable within predetermined parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gas-liquid two-phase flow is very common in industrial applications, especially in the oil and gas, chemical, and nuclear industries. As operating conditions change such as the flow rates of the phases, the pipe diameter and physical properties of the fluids, different configurations called flow patterns take place. In the case of oil production, the most frequent pattern found is slug flow, in which continuous liquid plugs (liquid slugs) and gas-dominated regions (elongated bubbles) alternate. Offshore scenarios where the pipe lies onto the seabed with slight changes of direction are extremely common. With those scenarios and issues in mind, this work presents an experimental study of two-phase gas-liquid slug flows in a duct with a slight change of direction, represented by a horizontal section followed by a downward sloping pipe stretch. The experiments were carried out at NUEM (Núcleo de Escoamentos Multifásicos UTFPR). The flow initiated and developed under controlled conditions and their characteristic parameters were measured with resistive sensors installed at four pipe sections. Two high-speed cameras were also used. With the measured results, it was evaluated the influence of a slight direction change on the slug flow structures and on the transition between slug flow and stratified flow in the downward section.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Centrifugal pumps are vastly used in many industrial applications. Knowledge of how these components behave in several circumstances is crucial for the development of more efficient and, therefore, less expensive pumping installations. The combination of multiple impellers, vaned diffusers and a volute might introduce several complex flow characteristics that largely deviate from regular inviscid pump flow theory. Computational Fluid Dynamics can be very helpful to extract information about which physical phenomena are involved in such flows. In this sense, this work performs a numerical study of the flow in a two-stage centrifugal pump (Imbil ITAP 65-330/2) with a vaned diffuser and a volute. The flow in the pump is modeled using the software Ansys CFX, by means of a multi-block, transient rotor-stator technique, with structured grids for all pump parts. The simulations were performed using water and a mixture of water and glycerin as work fluids. Several viscosities were considered, in a range between 87 and 720 cP. Comparisons between experimental data obtained by Amaral (2007) and numerical head curves showed a good agreement, with an average deviation of 6.8% for water. The behavior of velocity, pressure and turbulence kinetic energy fields was evaluated for several operational conditions. In general, the results obtained by this work achieved the proposed goals and are a significant contribution to the understanding of the flow studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Forensic speaker comparison exams have complex characteristics, demanding a long time for manual analysis. A method for automatic recognition of vowels, providing feature extraction for acoustic analysis is proposed, aiming to contribute as a support tool in these exams. The proposal is based in formant measurements by LPC (Linear Predictive Coding), selectively by fundamental frequency detection, zero crossing rate, bandwidth and continuity, with the clustering being done by the k-means method. Experiments using samples from three different databases have shown promising results, in which the regions corresponding to five of the Brasilian Portuguese vowels were successfully located, providing visualization of a speaker’s vocal tract behavior, as well as the detection of segments corresponding to target vowels.