3 resultados para Curvas de frequência acumulada

em Repositório Institucional da Universidade Tecnológica Federal do Paraná (RIUT)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents the development and modification of techniques to reduce the effects of load variation and mains frequency deviation in repetitive controllers applied to active power filters. To minimize the effects of aperiodic signals resulting from the connection or disconnection of non-linear loads is developed a technique which recognizes linear and nonlinear loads, and operates to reset the controller only when the error due to the transition of considerable value, and the transition is from non-linear to linear load. An algorithm to adapt the gain of the repetitive controller, based on a sigmoid function adaptation, in order to minimize the effects caused by random noise in the measurement system is also used. This work also analyzes the effects of frequency variation and presents the main methods to cope with this situation. Some solutions are the change in the number of samples per period and the variation of the sampling rate. The first has the advantage of using linear design techniques and results in a time invariant system. The second method changes the sampling frequency and leads to a time variant system that demands a difficult analysis of stability. The proposed algorithms were tested using the methods of truncation of the number of samples and the method of changing the sampling rate of the system to compensate possible frequency variations of the grid. Experimental results are presented to validate the proposal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical Submersible Pump (ESP) is used as an artificial lift technique. However, pumping viscous oil is generally associated with low Reynolds number flows. This condition leads to a performance degradation respect to the performance expected from the regular operation with water that most of the centrifugal pumps are originally designed for. These issues are considered in this investigation through a numerical study of the flow in two different multistage, semi-axial type ESPs. This investigation is carried out numerically using a Computational Fluid Dynamics (CFD) package, where the transient RANS equations are solved numerically. The turbulence is modeled using the SST model. Head curves for several operating conditions are compared with manufacturer’s curves and experimental data for a three-stage ESP, showing good agreement for a wide range of fluid viscosities and rotational speeds. Dimensionless numbers (n, n, n e Re) are used to investigate performance degradation of the ESPs. In addition, flow phenomena through the impellers of the ESPs are investigated using flow field from numerical results. Results show that performance degradation is directly related to rotational Reynolds number, Re. In addition, it was verified that performance degradation occurs for constant normalized specific speedn, which shows that performance degradation occurs similarly for different centrifugal pumps. Moreover, experimental data and numerical results agreed with a correlation from literature between head and flow correction factors proposed by Stepanoff (1967). A definition of modified Reynolds number was proposed and relates the head correction factor to viscosity. A correlation between head correction factor and the modified Reynolds number was proposed, which agreed well with numerical and experimental data. Then, a method to predict performance degradation based on the previous correlations was proposed. This method was compared with others from literature. In general, results and conclusions from this work can also be useful to bring more information about the flow of highly viscous fluids in pumps, especially in semi-axial, multistage ESPs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study has as general aim to propose a spatial map of doses as an auxiliary tool in assessing the need for optimization of the workplace in nuclear medicine services. As specific aims, we assessed the workers individual dosimetry; we analyzed the facilities of the nuclear medicine services; and we evaluated environment exposure rates. The research is characterized as a case study, with an exploratory and explanatory nature. It was conducted in three Nuclear Medicine Services, all established in the Northwest of the Paraná State. Results indicated that the evaluated dose rates and workers dosimetry, in all the dependencies of the surveyed services, are within the limits of annual doses. However some exceeded the limits recommended in the standard CNEN-NN 3:01 (2014). It was concluded that the spatial map dose is an important tool for nuclear medicine services because it facilitates the visualization of areas with highest concentration of radiation, and also helps in the constant review of these measures and resources, aiding in the identification of any failures and shortcomings, providing resources to correct any issues and prevent their repetition. The spatial map dose is also important for the regular inspection, evaluating if the radiation protection objectives are being met.