2 resultados para Análise de qualidade da água

em Repositório Institucional da Universidade Tecnológica Federal do Paraná (RIUT)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was developed in objecting to investigate the use and occupation of land in 1999, 2005, 2011 e 2015 and estimate soil degradation by laminar erosion and the relation with water quality in 2015 in the catchment basin of the Barro Preto river, Coronel Vivida – PR. For multitemporal analysis of use and occupation of land in the basin used in the Landsat 5, 7 and 8 images and Geographic Information System. The laminar erosion was estimated by the Universal Soil Loss Equation through the systematization of calculations of the factors that compose the equation in SPRING/INPE. The water quality of the studied river section was evaluated according to the Water Quality Idex and the Resolution CONAMA n. 357/2005. The multitemporal analysis of the use and occupation of land has demonstrated that basin is predominantly agricultural in all years studied, as well as the permanent preservation area presents it not regularized during the period in accordance with the Brazilian Forest Code in force. In relation the quantification of laminar soil erosion in the study period, the rainfall and runoff factor was estimated considering the rainfall data from 1986 to 2014 and resulted in a value of 11.573,47 MJ/ha.mm/a. The Dystrophic Red Latosol, Dystrophic Red Nitisol, Fluvisol and Leptosol soil erodibility factor were 0,0138, 0,0137, 0,0207, 0,0196 t.ha.h/ha.MJ.mm/a, respectively. The topographical factor has demonstrated that the catchment basin has the rough terrain because the moderate and moderate strong classes are dominant in the study area. The cover and management and support practice factors were estimated according to the multitemporal analysis of the use and occupation of land in the basin and the values ranged from 0,0006 to 0,0688. The soil losses by laminar erosion were simulated with agriculture areas with corn and soybeans in no-till. The soil losses with maize crop in no-till in 1999, 2005, 2011 and 2015 were 9.782,75, 10.592,71, 9.636,61 e 11.058,26 t/year, respectively, and soybeans crops in no-till were 15.140,01, 16.645,20, 14.662,14 e 17.049,85 t/year, respectively. In relation with water quality of the section studied river, the average of Water Quality Index during the season were 55,47, 53,09 and 49,72, for the first, second and third sample point, respectively. Indication a decrease in water quality since the source to the last sample point. It is concluded that the use and occupation of land in the catchment basin interferes in the water quality, as well as in soil degradation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work presents a low cost architecture for development of synchronized phasor measurement units (PMU). The device is intended to be connected in the low voltage grid, which allows the monitoring of transmission and distribution networks. Developments of this project include a complete PMU, with instrumentation module for use in low voltage network, GPS module to provide the sync signal and time stamp for the measures, processing unit with the acquisition system, phasor estimation and formatting data according to the standard and finally, communication module for data transmission. For the development and evaluation of the performance of this PMU, it was developed a set of applications in LabVIEW environment with specific features that let analyze the behavior of the measures and identify the sources of error of the PMU, as well as to apply all the tests proposed by the standard. The first application, useful for the development of instrumentation, consists of a function generator integrated with an oscilloscope, which allows the generation and acquisition of signals synchronously, in addition to the handling of samples. The second and main, is the test platform, with capabality of generating all tests provided by the synchronized phasor measurement standard IEEE C37.118.1, allowing store data or make the analysis of the measurements in real time. Finally, a third application was developed to evaluate the results of the tests and generate calibration curves to adjust the PMU. The results include all the tests proposed by synchrophasors standard and an additional test that evaluates the impact of noise. Moreover, through two prototypes connected to the electrical installation of consumers in same distribution circuit, it was obtained monitoring records that allowed the identification of loads in consumer and power quality analysis, beyond the event detection at the distribution and transmission levels.