6 resultados para Sistema de Mensuração e Desempenho

em Repositório Institucional da Universidade Federal do Rio Grande do Norte


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This research consists in studying the influence of the various type of construction systems of roofs with their energy efficiency as well as on the cost benefit for the commercial buildings on the temperatures condition of the city of Natal/RN. The main goal of this research is to analyze the cost benefit of the construction systems of roofs available on the market, taking into consideration the energy efficiency of the commercial buildings artificially air conditioned in order to be used by the projectors and to be adequated to the temperatures condition of the city of Natal/RN. The method of valuation of the cost benefit of roof systems consists in six steps: Features and simulation of the reference building; Analyze of sensitivity; Analyzes, features and simulation of alternatives of roof construction systems; Analyze of the cost of implementation; Analyze of the benefits of the alternatives comparing to the base case; And finally the analyze of the cost benefit. The model type chosen as reference was stores with pre molded buildings and system of roof with fiber ciment and ceiling . The thermal results showed the influence of the roof system on the energy efficiency of the building. The Final results of the simulations of the alternatives comes to a conclusion that the absortance is the variable that presents the best cost benefit relation and the reduction on the thermal transmittance still has limitations because of the high cost

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In recent decades the public sector comes under pressure in order to improve its performance. The use of Information Technology (IT) has been a tool increasingly used in reaching that goal. Thus, it has become an important issue in public organizations, particularly in institutions of higher education, determine which factors influence the acceptance and use of technology, impacting on the success of its implementation and the desired organizational results. The Technology Acceptance Model - TAM was used as the basis for this study and is based on the constructs perceived usefulness and perceived ease of use. However, when it comes to integrated management systems due to the complexity of its implementation,organizational factors were added to thus seek further explanation of the acceptance of such systems. Thus, added to the model five TAM constructs related to critical success factors in implementing ERP systems, they are: support of top management, communication, training, cooperation, and technological complexity (BUENO and SALMERON, 2008). Based on the foregoing, launches the following research problem: What factors influence the acceptance and use of SIE / module academic at the Federal University of Para, from the users' perception of teachers and technicians? The purpose of this study was to identify the influence of organizational factors, and behavioral antecedents of behavioral intention to use the SIE / module academic UFPA in the perspective of teachers and technical users. This is applied research, exploratory and descriptive, quantitative with the implementation of a survey, and data collection occurred through a structured questionnaire applied to a sample of 229 teachers and 30 technical and administrative staff. Data analysis was carried out through descriptive statistics and structural equation modeling with the technique of partial least squares (PLS). Effected primarily to assess the measurement model, which were verified reliability, convergent and discriminant validity for all indicators and constructs. Then the structural model was analyzed using the bootstrap resampling technique like. In assessing statistical significance, all hypotheses were supported. The coefficient of determination (R ²) was high or average in five of the six endogenous variables, so the model explains 47.3% of the variation in behavioral intention. It is noteworthy that among the antecedents of behavioral intention (BI) analyzed in this study, perceived usefulness is the variable that has a greater effect on behavioral intention, followed by ease of use (PEU) and attitude (AT). Among the organizational aspects (critical success factors) studied technological complexity (TC) and training (ERT) were those with greatest effect on behavioral intention to use, although these effects were lower than those produced by behavioral factors (originating from TAM). It is pointed out further that the support of senior management (TMS) showed, among all variables, the least effect on the intention to use (BI) and was followed by communications (COM) and cooperation (CO), which exert a low effect on behavioral intention (BI). Therefore, as other studies on the TAM constructs were adequate for the present research. Thus, the study contributed towards proving evidence that the Technology Acceptance Model can be applied to predict the acceptance of integrated management systems, even in public. Keywords: Technology

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em: . Acesso em: 04 out. 2010.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This master thesis aims to assess the influence of the design decisions on the energy building performance of hotels. The research is based on the integration of field study and computer simulation. Firstly, a detailed field study is carried out to identify the characteristics of hotels in Natal, Rio Grande do Norte. The items assessed are occupancies, light and equipment densities, types of air conditioning, total and monthly energy consumption, among others. A second and more comprehensive field study is carried out to identify the range of occurrence of architectural variables, with a larger number of buildings. A base case is modelled in VisualDOE, based on the first field study. Then, a first set of simulations are run to explore the sensitivity of the variables on the energy consumption. The results analyses were the base of a second set of simulations, which combined the most influential variables. The results of 384 models were assessed, and the impacts of design decisions were quantified. The study discusses tendencies and recommendations, as well as the methods advantages and disadvantages