6 resultados para Desempenho superior da firma

em Repositório Institucional da Universidade Federal do Rio Grande do Norte


Relevância:

30.00% 30.00%

Publicador:

Resumo:

SILVA, Hiran Francisco Oliveira Lopes da. A juste estruturale educação superior no Brasil: princípios negados. 206 f., 2007. Tese (Doutorado em Educação) - Universidade Federal da Paraiba, João Pessoa, 2007.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Brazil, the selection of school principals is set in a decentralized manner by each state and city, such that processes may vary with time for a specific locality. In the state of Bahia, school principals were appointed by a higher political hierarchy until 2008, when schools under state administration started selecting principals by elections. The main goal of this work is to evaluate whether changing this specific rule affected students proficiency levels. This is achieved by using a panel data and difference-in-differences approachs that compares state schools (treatment group) to city schools (control group) that did not face a selection rule change and thus kept having their principals politically appointed. The databases used are Prova Brasil 2007, 2009 and 2011, the first one prior and the other two former to the policy change. Our results suggest that students attending schools with principals that are selected and elected have slightly lower mean proficiency levels both in mathematics and in portuguese exams than those attending schools with appointed principals. This result, according to the literature, could be related to perverse effects of selecting school administrators by vote, such as corporatism, clientelism and politicization of the school environment

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper comprises an investigation on the influence of the variable family backgrounds (father school level, mother school level and family income) over the pupil s performance in admissions examination (entrance test or PROITEC) at Instituto Federal de Educação, Ciência e Tecnologia do Rio Grande do Norte (IFRN). From that point of view, the main goal of this research is to analyze the influence of the family background as a determiner of the pupil´s performance in the access to Technical and Professional education at IFRN. Secondary data were used from two databases (entrance test and PROITEC) adding up to 19.226 observations to the vacancies offered in the year of 2013. Aiming at achieving the proposed goal, a conceptual model composed of three hypothesis was developed. The results were presented in four stages: stage I presentation of the descriptive statistical results of the two databases; stage II separation of the campi in clusters; stage III analysis of multiple regressions; stage IV analysis of the logistics regressions. Two statistical tests were used to validate the hypothesis: T-test and Wald test. Hypothesis 1 and 2 were confirmed and H3 was refused. The results presented favorable causal connections to the family income and the father school level variables (with bigger effect for fathers with a higher education degree). The mother school level variable did not provide statistical significance for this research. Based on this result, after this work, this institution is to develop a strategic plan to assist in the success rate of students preparing diagnoses in order to diminish the effects of the variables that impacted negatively

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This master thesis aims to assess the influence of the design decisions on the energy building performance of hotels. The research is based on the integration of field study and computer simulation. Firstly, a detailed field study is carried out to identify the characteristics of hotels in Natal, Rio Grande do Norte. The items assessed are occupancies, light and equipment densities, types of air conditioning, total and monthly energy consumption, among others. A second and more comprehensive field study is carried out to identify the range of occurrence of architectural variables, with a larger number of buildings. A base case is modelled in VisualDOE, based on the first field study. Then, a first set of simulations are run to explore the sensitivity of the variables on the energy consumption. The results analyses were the base of a second set of simulations, which combined the most influential variables. The results of 384 models were assessed, and the impacts of design decisions were quantified. The study discusses tendencies and recommendations, as well as the methods advantages and disadvantages