6 resultados para Conforto ergonômico
em Repositório Institucional da Universidade Federal do Rio Grande do Norte
Resumo:
The present research concerns about outdoor s thermal comfort conditions in hot-humid climate cities, understanding that life quality is a result of the urban object s type built for the human being in an environment with specific climate and morphological characteristics. It is presented as object of study the correlation between the neighborhood Renascença II s microclimate in São Luis /MA-Brazil, hot-humid climate city, and its urban morphological changes. As well as the thermal comfort s satisfaction level of its outdoor users. The research has as general goal to diagnosis the way these transformations caused by the urbanization influence the Renascença II s microclimate, identifying critical spots of the studied area, in order to contribute with land use recommendations based on bioclimatic architecture concepts and supply bases to urban design decisions adequate to the São Luis climate. It is presented as theoretical bases the urban climate, its concepts and elements. After that, the thermal comfort conditioners and its prediction models of thermal comfort sensation in outdoor are presented. The predictive models are presented along with bioclimatic assessment methods. Finally the use of bioclimatic assessment as an effective tool to identify places that need changes or preservation in order to seek environment quality. The applied methodology was based on the studies of Katzschner (1997), complemented by Oliveira s (1988) and Bustos Romero s (2001) studies that suggest an analysis and evaluation of maps of topography, buildings floors, land use, green areas and land covering, in order to overlap their characteristics and identify climate variable s measurements points; then a quantitative analysis of the climate variables (air temperature and humidity, wind speed and direction) of the chosen points takes place. It was perceived that Renaissance II has no permanence areas as squares or parks, its outdoor has little vegetation and presets high land impermeability and built density levels. The majority of the people interviewed said that was comfortable in a range of air temperature between 27,28ºC and 30,71ºC. The elaboration of a neighborhood master plan is important, which defines strategies for improvement of the life quality of its inhabitants
Resumo:
The assessment of building thermal performance is often carried out using HVAC energy consumption data, when available, or thermal comfort variables measurements, for free-running buildings. Both types of data can be determined by monitoring or computer simulation. The assessment based on thermal comfort variables is the most complex because it depends on the determination of the thermal comfort zone. For these reasons, this master thesis explores methods of building thermal performance assessment using variables of thermal comfort simulated by DesignBuilder software. The main objective is to contribute to the development of methods to support architectural decisions during the design process, and energy and sustainable rating systems. The research method consists on selecting thermal comfort methods, modeling them in electronic sheets with output charts developed to optimize the analyses, which are used to assess the simulation results of low cost house configurations. The house models consist in a base case, which are already built, and changes in thermal transmittance, absorptance, and shading. The simulation results are assessed using each thermal comfort method, to identify the sensitivity of them. The final results show the limitations of the methods, the importance of a method that considers thermal radiance and wind speed, and the contribution of the chart proposed
Resumo:
This research covers the topic of social housing and its relation to thermal comfort, so applied to an architectural and urban intervention in land situated in central urban area of Macaíba/RN, Brazil. Reflecting on the role of design and use of alternative building materials in the search for better performance is one of its main goals. The hypothesis is that by changing design parameters and choice of materials, it is possible to achieve better thermal performance results. Thus, we performed computer simulations of thermal performance and natural ventilation using computational fluid dynamics or CFD (Computational Fluid Dynamics). The presentation of the thermal simulation followed the methodology proposed in the dissertation Negreiros (2010), which aims to find the percentage of the amount of hours of comfort obtained throughout the year, while data analysis was made of natural ventilation from images generated by the images extracted from the CFD. From model building designed, was fitted an analytical framework that results in a comparison between three different proposals for dwellings housing model, which is evaluated the question of the thermal performance of buildings, and also deals with the spatial variables design, construction materials and costs. It is concluded that the final report confirmed the general hypotheses set at the start of the study, it was possible to quantify the results and identify the importance of design and construction materials are equivalent, and that, if combined, lead to gains in thermal performance potential.
Resumo:
The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air
Resumo:
This research aimed to identify the link between the layout of workspaces in offices and the design strategies for environmental comfort. Strategies surveyed were focused on the thermal, visual and luminic comfort. In this research, visual comfort is related to issues of visual integration within and between the interior and exterior of the building. This is a case study conducted at the administrative headquarters of Centro Regional Nordeste do Instituto de Pesquisas Espaciais (INPE-CRN), located in Natal/RN. The methodological strategy used was the Post-Occupancy Evaluation, which combined the survey data on the building (layout of workspaces, bioclimatic strategies adopted in the design, use of these strategies) with some techniques aimed at acquiring qualitative information related to users. The workspace layout is primordial to satisfaction and productivity of workers. Issues such as concentration, communication, privacy, personal identity, density and space efficiency, barriers (access, visual and even ventilation and lighting), among others, are associated with the layout. The environmental comfort is one of the essential elements to maintaining life quality in workplace. Moreover, it is an important factor in user`s perception of the space in which he or she are inserted. Both layout and environmental comfort issues should be collected and analyzed in the establishment phase of the programming step. That way, it is possible to get adequate answers to these questions in subsequent project phases. It was found that changes in the program that occurred over time, especially concerning persons (number and characteristics), resulted in changes in layout, generating high density and inflexible environments. It turns difficult to adjust the furniture to the occupants` requirement, including comfort needs. However, the presence of strategies for environmental quality provides comfort to spaces, ensuring that, even in situations not considered optimal, users perceive the environment in a positive way. It was found that the relationship between environmental comfort and layout takes the following forms: in changing the perception of comfort, depending on the layout of the arrangements; adjustments in layout, due to needs for comfort; and the elevation of user satisfaction and environmental quality due to the presence of strategies comfort even in situations of inadequate layout
Resumo:
This study was intended to investigate how the urban form has been influencing the changes in the climate of the city and make a correlation between the climate and the thermal sensation of the users of open spaces. The research was developed in the district of Petrópolis in Natal/ RN whose occupation has been almost consolidated. Among other reasons, this district was selected because it was planned considering the environmental aspects of comfort. The methodologies used are based on KATZSCHNER (1997) and OLIVEIRA (1988) studies, which suggest the drawing and analysis of maps of the area under study, including topography, height of the buildings, land use, green areas, and types of soil pavement, as well as measurement of the environmental variables: air temperature, relative humidity, direction and wind speed for a comparative study. As part of this, study local users of the district were interviewed about their thermal sensations in open spaces. For the statistical analysis, data was collected at 10 distinct points characterized by BUSTOS ROMERO (2002), being 8 within the district and 2 at different places (outside the district), at climatologic stations, in 3 periods (August/2000, January/2002 and June/2002), for 4 consecutive days for each measurement (from Sunday to Wednesday) at the time of lower and higher temperatures in the city, 6:00 am and 1:00 pm, respectively. At the same time interviews were carried out with users of the open spaces in the area, totaling 171 valid formularies. The urban form showed a rather leveled topography, great diversity of land use and height of the buildings, with the existence of an area mostly occupied with high buildings, very little green area and soil practically impermeable. The statistical analysis showed high temperature and humidity levels. The wind direction is predominantly Southeast with extremely variable speeds. When the data from this district is compared with the data from other areas in the city and its outskirt, it was observed that this district is hotter and less ventilated than the others; besides, most users said that they felt uncomfortable in the local environmental conditions. The results of the analysis generated a zoning for the district with recommendations for soil occupation. The profile of the user was defined regarding the thermal comfort, as well as some discussion about the comfort parameters, including the proposal of limiting areas of temperature and humidity for the thermal comfort in the open spaces