2 resultados para electric potential

em Repositório Científico da Universidade de Évora - Portugal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to access the effect of the lakes in the atmospheric electrical field, measurements have been carried out near a large man-made lake in southern Portugal, the Alqueva reservoir, during the ALqueva hydro-meteorological EXperiment 2014. The purpose of these conjoint experiments was to study the impact of the Alqueva reservoir on the atmosphere, in particular on the local atmospheric electric environment by comparing measurements taken in the proximity of the lake. Two stations 10 km apart were used, as they were located up- and down-wind of the lake (Amieira and Parque Solar, respectively), in reference to the dominant northwestern wind direction. The up-wind station shows lower atmospheric electric potential gradient (PG) values than the ones observed in the down-wind station between 12 and 20 UTC. The difference in the atmospheric electric PG between the up-wind and the down-wind station is ~30 V/m during the day. This differential occurs mainly during the development of a lake breeze, between 10 and 18 UTC, as a consequence of the surface temperature gradient between the surrounding land and the lake water. In the analysis presented, a correlation is found between the atmospheric electric PG differences and both wind speed and temperature gradients over the lake, thus supporting the influence of the lake breeze over the observed PG variation in the two stations. Two hypotheses are provided to explain this observation: (1) The air that flows from the lake into the land station is likely to increase the local electric conductivity through the removal of ground dust and the transport of cleaner air from higher altitudes with significant light ion concentrations. With such an increase in conductivity, it is expected to see a reduction of the atmospheric electric PG; (2) the resulting air flow over the land station carries negative ions formed by wave splashing in the lake's water surface, as a result of the so-called balloelectric effect. These negative ions will form a space-charge density (SCD) that can reduce the atmospheric electric PG. A formulation is derived here in order to estimate the local SCD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Teknova have 2D steady-state models of the calciner but wish, in the long term, to have a 3D model that can also cover unsteady conditions, and can can model the loss of axisymmetry that someties occurs. Teknova also wish to understand the processes happening around the tip of the upper electrode, in particular the formation of a lip on it and the the shape of the empty region below it. The Study Group proposed potential models for the degree of graphitization, and for the granular flow. Also the Study Group considered the upper electrode in detail. The proposed model for the lip formation is by sublimation of carbon from the hottest parts of the furnace with redeposition in the region around the electrode, which may stick particles onto the electrode surface. In this model the region below the electrode would be a void, roughly a vertex-down conical cavity. The electric field near the lower rim of the electrode will then have a singularity and so the most intense heating of the charge will be around the rim. We conjecture that the reason why the lower electrode lasts so much longer than the upper is that it is not adjacent to a cavity like this, and therefore does not have a singularity in the field.