1 resultado para % area of radiolarian-related porosity
em Repositório Científico da Universidade de Évora - Portugal
Resumo:
Transpiration of two year-old olive trees of three different varieties, Arbequina, Cobrançosa and Galega (18 trees per variety), irrigated with three levels of salt (0, 80 or 200 mM NaCl) for about 90 days, was measured by a gravimetric method. To determine leaf area, each tree was photographed from the side against a white background and the total area of each projected image was determined with ImageJ software. To calibrate these area determinations, one tree of each variety was subsequently stripped of all its leaves and its total leaf area was accurately measured. A correlation was then obtained between the area on the photograph of this particular tree and the total area of the detached leaves of the same tree. Using the leaf area determined by this procedure, transpiration rates of the trees could be calculated. Knowing leaf and air temperatures and RH, it was possible to determine the difference in molar fraction of water between the leaf and the air. Using this and the values of the transpiration rate, stomatal conductance could be calculated (gs calc) and compared with the conductance measured on the same trees with a porometer (gs). Actual leaf area of a plant was 1,40 (Arbequina), 1,42 (Cobrançosa) or 1,24 (Galega) times the area measured with ImageJ on the photograph of the same plant. Leaf area of the trees, on average of all salt irrigations, was significantly higher on Arbequina (0,187 m2) then on the other two varieties (0,138 m2 or 0,148 m2, for Cobrançosa or Galega, respectively), but did not differ significantly in percentage of controls (0 salt). On average of all three varieties, leaf area was also higher on plants irrigated without salt (0,181 m2) than on plants exposed to 80 or 200 mM NaCl (0,152 m2 or 0,140 m2, respectively), which did not differ between them. The same significant difference was observed when leaf area was expressed as percentage of controls. Transpiration rate was significantly higher on Cobrançosa (1,17 mmol m-2 s-1), on average of all treatments, but there were no significant differences between Arbequina (1,08 mmol m-2 s-1) and Galega (0,82 mmol m-2 s-1). In percentage of controls, there were no significant differences between varieties. Salt reduced significantly the transpiration rate in all varieties, both the actual and percentual values, to about 50% or 30% of controls when exposed to 80 mM or 200 mM NaCl, respectively. Stomatal conductance (gs), assessed by porometry, was significantly higher in control plants, mainly in Cobrançosa (102 mmol m-2 s-1), then in Arbequina (77 mmol m-2 s-1) and the lower values were found in Galega (51 mmol m-2 s-1). Salt reduced gs, on average of the three varieties to 30% or 10% of controls on exposure to 80 mM or 200 mM NaCl, respectively. Calculated (gs calc) and measured (gs) values of stomatal conductance showed a close relation between them (0,967, R2 = 0,837) which indicates this non-destructive method to determine whole-plant leaf area to be reasonably accurate.