216 resultados para skeletal size
em Queensland University of Technology - ePrints Archive
Resumo:
Leucine is a key amino acid for initiating translation in muscle cells, but the dose-dependent effects of leucine on intracellular signaling are poorly characterized. This study examined the effect that increasing doses of leucine would have on changes in mechanistic target of rapamycin (mTOR)–mediated signaling, rates of protein synthesis, and cell size in C2C12 cells. We hypothesized that a leucine “threshold” exists, which represents the minimum stimulus required to initiate mTOR signaling in muscle cells. Acute exposure to 1.5, 3.2, 5.0, and 16.1 mM leucine increased phosphorylation of mTORSer2448 (~1.4-fold; P < .04), 4E-BP1 Thr37/46 (~1.9-fold; P < .001), and rpS6Ser235/6 (~2.3-fold; P < .001). However, only p70S6kThr389 exhibited a dose-dependent response to leucine with all treatments higher than control (~4-fold; P < .001) and at least 5 mM higher than the 1.5-mM concentration (1.2-fold; P < .02). Rates of protein synthesis were not altered by any treatment. Seven days of exposure to 0.5, 1.5, 5.0, and 16.5 mM leucine resulted in an increase in cell size in at least 5 mM treatments (~1.6-fold, P < .001 vs control). Our findings indicate that even at low leucine concentrations, phosphorylation of proteins regulating translation initiation signaling is enhanced. The phosphorylation of p70S6kThr389 follows a leucine dose-response relationship, although this was not reflected by the acute protein synthetic response. Nevertheless, under the conditions of the present study, it appears that leucine concentrations of at least 5 mM are necessary to enhance cell growth.
Resumo:
Background: Body cell mass (BCM) may be estimated in clinical practice to assess functional nutritional status, eg, in patients with anorexia nervosa. Interpretation of the data, especially in younger patients who are still growing, requires appropriate adjustment for size. Previous investigations of this general issue have addressed chemical rather than functional components of body composition and have not considered patients at the extremes of nutritional status, in whom the ability to make longitudinal comparisons is of particular importance. Objective: Our objective was to determine the power by which height should be raised to adjust BCM for height in women of differing nutritional status. Design: BCM was estimated by K-40 counting in 58 healthy women, 33 healthy female adolescents, and 75 female adolescents with anorexia nervosa. The relation between BCM and height was explored in each group by using log-log regression analysis. Results: The powers by which height should be raised to adjust BCM,A,ere 1.73. 1.73, and 2.07 in the women, healthy female adolescents, and anorexic female adolescents, respectively. A simplified version of the index, BCM/height(2), was appropriate for all 3 categories and was negligibly correlated with height. Conclusions: In normal-weight women, the relation between height and BCM is consistent with that reported previously between height and fat-free mass. Although the consistency of the relation between BCM and fat-free mass decreases with increasing weight loss, the relation between height and BCM is not significantly different between normal-weight and underweight women. The index BCM/height(2) is easy to calculate and applicable to both healthy and underweight women. This information may be helpful in interpreting body-composition data in clinical practice.
Resumo:
This paper presents a prototype tracking system for tracking people in enclosed indoor environments where there is a high rate of occlusions. The system uses a stereo camera for acquisition, and is capable of disambiguating occlusions using a combination of depth map analysis, a two step ellipse fitting people detection process, the use of motion models and Kalman filters and a novel fit metric, based on computationally simple object statistics. Testing shows that our fit metric outperforms commonly used position based metrics and histogram based metrics, resulting in more accurate tracking of people.
Resumo:
Organisations invest enormous sums of money in acquiring Enterprise Resource Planning (ERP) systems, presumably expecting positive impacts to the organisation and its functions. Despite the optimistic motives some ERP projects have reported nil or detrimental impacts. This paper studies the proposition that the size of an organisation (e.g. small, large) may have contributed to the differences in receiving benefits reported in prior studies in this domain. The alleged differences in organisational performance are empirically measured using a prior validated model, using five constructs and fortytwo sub-constructs. Information is gathered from three hundred and ten respondents representing twenty-seven public sector organisations. Results suggests that (1) larger organisations have received more benefits compared to small organisations, (2) small organisations demonstrated higher reliance on their ERP systems, (3) employment cohorts demonstrate significant differences in perceived benefits in small and large organisations.
Resumo:
Size distributions of expiratory droplets expelled during coughing and speaking and the velocities of the expiration air jets of healthy volunteers were measured. Droplet size was measured using the Interferometric Mie imaging (IMI) technique while the Particle Image Velocimetry (PIV) technique was used for measuring air velocity. These techniques allowed measurements in close proximity to the mouth and avoided air sampling losses. The average expiration air velocity was 11.7 m/s for coughing and 3.9 m/s for speaking. Under the experimental setting, evaporation and condensation effects had negligible impact on the measured droplet size. The geometric mean diameter of droplets from coughing was 13.5m and it was 16.0m for speaking (counting 1 to 100). The estimated total number of droplets expelled ranged from 947 – 2085 per cough and 112 – 6720 for speaking. The estimated droplet concentrations for coughing ranged from 2.4 - 5.2cm-3 per cough and 0.004 – 0.223 cm-3 for speaking.
Resumo:
A new Expiratory Droplet Investigation System (EDIS) was used to conduct the most comprehensive program of study to date, of the dilution corrected droplet size distributions produced during different respiratory activities.----- Distinct physiological processes were responsible for specific size distribution modes. The majority of particles for all activities were produced in one or more modes, with diameters below 0.8 µm. That mode occurred during all respiratory activities, including normal breathing. A second mode at 1.8 µm was produced during all activities, but at lower concentrations.----- Speech produced particles in modes near 3.5 µm and 5 µm. The modes became most pronounced during continuous vocalization, suggesting that the aerosolization of secretions lubricating the vocal chords is a major source of droplets in terms of number.----- Non-eqilibrium droplet evaporation was not detectable for particles between 0.5 and 20 μm implying that evaporation to the equilibrium droplet size occurred within 0.8 s.
Resumo:
In truck manufacturing, the exhaust and air inlet pipes are specialized equipment that requires highly skilled, heavy machinery and small batch production methods. This paper describes a project to develop the computer numerically controlled (CNC) pipe bending process for a truck component manufacturer. The company supplies a huge range of heavy duty truck parts to the domestic market and is a significant supplier in Australia. The company has been using traditional methods of machine assisted manual pipe bending techniques. In a drive of continuous improvement, the company has acquired a pre-owned CNC bending machine capable of bending pipes automatically up to 25 bends. However, due to process mismatch, this machine is only used for single bending operation. The researchers studied the bending system and changed the manufacturing process. Using an example exhaust pipe as the benchmark, a significant drop of manufacturing lead time from 70 minutes to 40 minutes for each pipe was demonstrated. There was also a decrease of material cost due to the multiple bends part in one piece without cutting excessive materials for each single bend like it used to be.