7 resultados para sheeting
em Queensland University of Technology - ePrints Archive
Resumo:
Crest-fixed steel claddings made of thin, high strength steel often suffer from local pull-through failures at their screw connections during high wind events such as storms and hurricanes. Adequate design provisions are not available for these cladding systems except for the expensive testing provisions. Since the local pull-through failures in the less ductile steel claddings are initiated by transverse splitting at the fastener holes, numerical studies have not been able to determine the pull-through failure loads. Numerical studies could be used if a reliable splitting criterion is available. Therefore a series of two-span cladding and small scale tests was conducted on a range of crest-fixed steel cladding systems under simulated wind uplift loads. The strains in the sheeting around the critical central support screw fastener holes were measured until the pull-through failure occurred. This paper presents the details of the experimental investigation and the results including a strain criterion for the local pull-through failures in crest-fixed steel claddings.
Resumo:
Much current Queensland media rhetoric, government policy and legislation on truancy and youth justice appears to be based on ideas of responsibilisation – of sheeting responsibility for children’s behaviour back onto their parents. This article examines the evidence of parental responsibility provisions in juvenile justice and truancy legislation in Queensland and the drivers behind this approach. It considers recent legislative initiatives as part of an international trend toward making parents ‘responsible’ for the wrongs of their children. It identifies the parental responsibility rhetoric appearing in recent ministerial statements and associated media reports. It then asks the questions – are these legislative provisions being enforced? And if so, are they successful? Are they simply adding to the administrative burdens placed on teachers and schools, and the socioeconomic burdens placed on already disadvantaged parents? Parental responsibility provisions have been discussed at length in the context of juvenile offending and research suggests that punishing parents for the acts of their children does not decrease delinquency. The paper asks how, as a society, we intend to evaluate these punitive measures against parents?
Resumo:
SET on a sparse stage with a ladder, a table, a few chairs and a backdrop of plastic sheeting, Hamlet Apocalypse retails the core of Shakespeare's story in combination with the actor's relation to the concept of the end of everything.
Resumo:
Crest-fixed steel claddings made of thin, high strength steel often suffer from local pull-through failures at their screw connections during high wind events such as storms and hurricanes. Currently there aren't any adequate design provisions for these cladding systems except for the expensive testing provisions. Since the local pull-through failures in the less ductile steel claddings are initiated by transverse splitting at the fastener hole, analytical studies have not been able to determine the pull-through failure loads. Analytical studies could be used if a reliable splitting criterion is available. Therefore a series of two-span cladding tests was conducted on a range of crest-fixed steel cladding systems under simulated wind uplift loads. The strains in the sheeting around the critical fastener holes were measured until the pull-through failure. This paper presents the details of the experimental investigation and the results including a strain criterion for the local pull-through failure.
Resumo:
Light gauge steel roofing systems made of thin profiled roof sheeting and battens are used commonly in residential, industrial and commercial buildings. Their critical design load combination is that due to wind uplift forces that occur during high wind events such as tropical cyclones and thunderstorms. However, premature local failures at their screw connections have been a concern for many decades since cyclone Tracy that devastated Darwin in 1974. Extensive research that followed cyclone Tracy on the pull-through and pull-out failures of roof sheeting to batten connections has significantly improved the safety of roof sheeting. However, this has made the batten to rafter/truss connection the weakest, and recent wind damage investigations have shown the failures of these connections and the resulting loss of entire roof structures. Therefore an experimental research program using both small scale and full scale air-box tests is currently under way to investigate the pull-through failures of thin-walled steel battens under high wind uplift forces. Tests have demonstrated that occurrence of pull-through failures in the bottom flanges of steel batttens and the need to develop simple test and design methods as a function of many critical parameters such as steel batten geometry, thickness and grade, screw fastener sizes and other fastening details. This paper presents the details of local failures that occur in light fauge roofing systems, a review of the current design and test methods for steel battens and associated short comings, and the test results obtained to date on pull-through failures of battens from small scale and full scale tests. Finally, it proposes the use of suitable small scale test methods that can be used by both researchers and manufacturers of such screw-fastened light gauge steel batten systems.
Resumo:
The last two decades have witnessed a fragmentation of previously integrated systems of production and service delivery with the advent of boundary-less, networked and porous organisational forms. This trend has been associated with the growth of outsourcing and increased use of contingent workers. One consequence of these changes is the development of production/service delivery systems based on complex national and international networks of multi-tiered subcontracting increasingly labelled as supply chains. A growing body of research indicates that subcontracting and contingent work arrangements affect design and decision-making processes in ways that can seriously undermine occupational health and safety (OHS). Elaborate supply chains also present a regulatory challenge because legal responsibility for OHS is diffused amongst a wider array of parties, targeting key decision-makers is more difficult, and government agencies encounter greater logistical difficulties trying to safeguard contingent workers. In a number of industries these problems have prompted new forms of regulatory intervention, including mechanisms for sheeting legal responsibility to the top of supply chains, contractual tracking devices and increasing industry, union and community involvement in enforcement. After describing the problems just alluded to this paper examines recent efforts to regulate supply chains to safeguard OHS in the United Kingdom and Australia.
Resumo:
Thin profiled steel roof sheeting and battens are increasingly used in the construction of roofing systems of residential, commercial, industrial and farm buildings in Australia. The critical load combination of external wind suction and internal wind pressures that occur during high wind events such as thunderstorms and tropical cylcones often dislocate the roofing systems partially or even completely due to premature roof connection failures. Past wind damage investigations have shown that roof sheeting failures occured at their screw connections to battens. In most of these cases, the screw fastener head pulled through the thin roof sheeting whilst the screw fasteners also pulled out from the battens. Research studis undertaken on the roof sheeting to batten connection failures have improved this situation. However, the batten to rafter or truss connections have not been investigated adequately. Failure of these connections can cause the failure of the entire roof structure as observed during the recent high wind events. Therefore a detailed experimental study consisting of both small scale and full scale tests has been undertaken to investigate the steel roof batten pull-through failures in relation to many critical parameters such as steel batten geometry, thickness and grade, screw fastener head sizes and screw tightening. This paper presents the details of this experimental study and the pull-through failure load results obtained from them. Finally it discusses the development of suitable design rules that can be used to determine the pull-through connection capacities of thin steel roof battens under wind uplift loads.