98 resultados para osmotic swelling

em Queensland University of Technology - ePrints Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was designed to derive central and peripheral oxygen transmissibility (Dk/t) thresholds for soft contact lenses to avoid hypoxia-induced corneal swelling (increased corneal thickness) during open eye wear. Central and peripheral corneal thicknesses were measured in a masked and randomized fashion for the left eye of each of seven subjects before and after 3 h of afternoon wear of five conventional hydrogel and silicone hydrogel contact lens types offering a range of Dk/t from 2.4 units to 115.3 units. Curve fitting for plots of change in corneal thickness versus central and peripheral Dk/t found threshold values of 19.8 and 32.6 units to avoid corneal swelling during open eye contact lens wear for a typical wearer. Although some conventional hydrogel soft lenses are able to achieve this criterion for either central or peripheral lens areas (depending on lens power), in general, no conventional hydrogel soft lenses meet both the central and peripheral thresholds. Silicone hydrogel contact lenses typically meet both the central and peripheral thresholds and use of these lenses therefore avoids swelling in all regions of the cornea. ' 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 92B: 361–365, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modelling of water flow and associated deformation in unsaturated reactive soils (shrinking/swelling soils) is important in many applications. The current paper presents a method to capture soil swelling deformation during water infiltration using Particle Image Velocimetry (PIV). The model soil material used is a commercially available bentonite. A swelling chamber was setup to determine the water content profile and extent of soil swelling. The test was run for 61 days, and during this time period, the soil underwent on average across its width swelling of about 26% of the height of the soil column. PIV analysis was able to determine the amount of swelling that occurred within the entire face of the soil box that was used for observations. The swelling was most apparent in the top layers with strains in most cases over 100%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrogels, which are three-dimensional crosslinked hydrophilic polymers, have been used and studied widely as vehicles for drug delivery due to their good biocompatibility. Traditional methods to load therapeutic proteins into hydrogels have some disadvantages. Biological activity of drugs or proteins can be compromised during polymerization process or the process of loading protein can be really timeconsuming. Therefore, different loading methods have been investigated. Based on the theory of electrophoresis, an electrochemical gradient can be used to transport proteins into hydrogels. Therefore, an electrophoretic method was used to load protein in this study. Chemically and radiation crosslinked polyacrylamide was used to set up the model to load protein electrophoretically into hydrogels. Different methods to prepare the polymers have been studied and have shown the effect of the crosslinker (bisacrylamide) concentration on the protein loading and release behaviour. The mechanism of protein release from the hydrogels was anomalous diffusion (i.e. the process was non-Fickian). The UV-Vis spectra of proteins before and after reduction show that the bioactivities of proteins after release from hydrogel were maintained. Due to the concern of cytotoxicity of residual monomer in polyacrylamide, poly(2-hydroxyethyl- methacrylate) (pHEMA) was used as the second tested material. In order to control the pore size, a polyethylene glycol (PEG) porogen was introduced to the pHEMA. The hydrogel disintegrated after immersion in water indicating that the swelling forces exceeded the strength of the material. In order to understand the cause of the disintegration, several different conditions of crosslinker concentration and preparation method were studied. However, the disintegration of the hydrogel still occurred after immersion in water principally due to osmotic forces. A hydrogel suitable for drug delivery needs to be biocompatible and also robust. Therefore, an approach to improving the mechanical properties of the porogen-containing pHEMA hydrogel by introduction of an inter-penetrating network (IPN) into the hydrogel system has been researched. A double network was formed by the introduction of further HEMA solution into the system by both electrophoresis and slow diffusion. Raman spectroscopy was used to observe the diffusion of HEMA into the hydrogel prior to further crosslinking by ã-irradiation. The protein loading and release behaviour from the hydrogel showing enhanced mechanical property was also studied. Biocompatibility is a very important factor for the biomedical application of hydrogels. Different hydrogels have been studied on both a three-dimensional HSE model and a HSE wound model for their biocompatibilities. They did not show any detrimental effect to the keratinocyte cells. From the results reported above, these hydrogels show good biocompatibility in both models. Due to the advantage of the hydrogels such as the ability to absorb and deliver protein or drugs, they have potential to be used as topical materials for wound healing or other biomedical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aims: Lower-limb lymphoedema is a serious and feared sequela after treatment for gynaecological cancer. Given the limited prospective data on incidence of and risk factors for lymphoedema after treatment for gynaecological cancer we initiated a prospective cohort study in 2008. Methods: Data were available for 353 women with malignant disease. Participants were assessed before treatment and at regular intervals after treatment for two years. Follow-up visits were grouped into time-periods of six weeks to six months (time 1), nine months to 15 months (time 2), and 18 months to 24 months (time 3). Preliminary data analyses were undertaken up to time 2 using generalised estimating equations to model the repeated measures data of Functional Assessment of Cancer Therapy-General (FACT-G) quality of life (QoL) scores and self-reported swelling at each follow-up period (best-fitting covariance structure). Results: Depending on the time-period, between 30% and 40% of patients self-reported swelling of the lower limb. The QoL of those with self-reported swelling was lower at all time-periods compared with those who did not have swelling. Mean (95% CI) FACT-G scores at time 0, 1 and 2 were 80.7 (78.2, 83.2), 83.0 (81.0, 85.0) and 86.3 (84.2, 88.4), respectively for those with swelling and 85.0 (83.0, 86.9), 86.0 (84.1, 88.0) and 88.9 (87.0, 90.7), respectively for those without swelling. Conclusions: Lower-limb swelling adversely influences QoL and change in QoL over time in patients with gynaecological cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Controlled drug delivery is a key topic in modern pharmacotherapy, where controlled drug delivery devices are required to prolong the period of release, maintain a constant release rate, or release the drug with a predetermined release profile. In the pharmaceutical industry, the development process of a controlled drug delivery device may be facilitated enormously by the mathematical modelling of drug release mechanisms, directly decreasing the number of necessary experiments. Such mathematical modelling is difficult because several mechanisms are involved during the drug release process. The main drug release mechanisms of a controlled release device are based on the device’s physiochemical properties, and include diffusion, swelling and erosion. In this thesis, four controlled drug delivery models are investigated. These four models selectively involve the solvent penetration into the polymeric device, the swelling of the polymer, the polymer erosion and the drug diffusion out of the device but all share two common key features. The first is that the solvent penetration into the polymer causes the transition of the polymer from a glassy state into a rubbery state. The interface between the two states of the polymer is modelled as a moving boundary and the speed of this interface is governed by a kinetic law. The second feature is that drug diffusion only happens in the rubbery region of the polymer, with a nonlinear diffusion coefficient which is dependent on the concentration of solvent. These models are analysed by using both formal asymptotics and numerical computation, where front-fixing methods and the method of lines with finite difference approximations are used to solve these models numerically. This numerical scheme is conservative, accurate and easily implemented to the moving boundary problems and is thoroughly explained in Section 3.2. From the small time asymptotic analysis in Sections 5.3.1, 6.3.1 and 7.2.1, these models exhibit the non-Fickian behaviour referred to as Case II diffusion, and an initial constant rate of drug release which is appealing to the pharmaceutical industry because this indicates zeroorder release. The numerical results of the models qualitatively confirms the experimental behaviour identified in the literature. The knowledge obtained from investigating these models can help to develop more complex multi-layered drug delivery devices in order to achieve sophisticated drug release profiles. A multi-layer matrix tablet, which consists of a number of polymer layers designed to provide sustainable and constant drug release or bimodal drug release, is also discussed in this research. The moving boundary problem describing the solvent penetration into the polymer also arises in melting and freezing problems which have been modelled as the classical onephase Stefan problem. The classical one-phase Stefan problem has unrealistic singularities existed in the problem at the complete melting time. Hence we investigate the effect of including the kinetic undercooling to the melting problem and this problem is called the one-phase Stefan problem with kinetic undercooling. Interestingly we discover the unrealistic singularities existed in the classical one-phase Stefan problem at the complete melting time are regularised and also find out the small time behaviour of the one-phase Stefan problem with kinetic undercooling is different to the classical one-phase Stefan problem from the small time asymptotic analysis in Section 3.3. In the case of melting very small particles, it is known that surface tension effects are important. The effect of including the surface tension to the melting problem for nanoparticles (no kinetic undercooling) has been investigated in the past, however the one-phase Stefan problem with surface tension exhibits finite-time blow-up. Therefore we investigate the effect of including both the surface tension and kinetic undercooling to the melting problem for nanoparticles and find out the the solution continues to exist until complete melting. The investigation of including kinetic undercooling and surface tension to the melting problems reveals more insight into the regularisations of unphysical singularities in the classical one-phase Stefan problem. This investigation gives a better understanding of melting a particle, and contributes to the current body of knowledge related to melting and freezing due to heat conduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To quantitatively assess and compare the quality of life (QoL) of women with a self-reported diagnosis of lower limb lymphedema (LLL), to women with lower limb swelling (LLS), and to women without LLL or LLS following treatment for endometrial cancer. Methods 1399 participants in the Australian National Endometrial Cancer Study were sent a follow-up questionnaire 3–5 years after diagnosis. Women were asked if they had experienced swelling in the lower limbs and, if so, whether they had received a diagnosis of lymphedema by a health professional. The 639 women who responded were categorised as: Women with LLL (n = 68), women with LLS (n = 177) and women without LLL or LLS (n = 394). Multivariable-adjusted generalized linear models were used to compare women’s physical and mental QoL by LLL status. Results On average, women were 65 years of age and 4 years after diagnosis. Women with LLL had clinically lower physical QoL (M= 41.8, SE= 1.4) than women without LLL or LLS (M= 45.1, SE= 0.8, p = .07), however, their mental QoL was within the normative range (M= 49.6; SE= 1.1 p = 1.0). Women with LLS had significantly lower physical (M= 41.0, SE= 1.0, p = .003) and mental QoL (M= 46.8; SE= 0.8, p < .0001) than women without LLL or LLS (Mental QoL: M= 50.6, SE= 0.8). Conclusion Although LLL was associated with reductions in physical QoL, LLS was related to reductions in both physical and mental QoL 3-5 years after cancer treatment. Early referral to evidence-based lymphedema programs may prevent long-term impairments to women’s QoL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The deformation of a rectangular block into an annular wedge is studied with respect to the state of swelling interior to the block. Nonuniform swelling fields are shown to generate these flexure deformations in the absence of resultant forces and bending moments. Analytical expressions for the deformation fields demonstrate these effects for both incompressible and compressible generalizations of conventional hyperelastic materials. Existing results in the absence of a swelling agent are recovered as special cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly sodium acrylate (PSA)-coated Magnetic Nanoparticles (PSA-MNPs) were synthesized as smart osmotic draw agent (SMDA) for water desalination by forward osmosis (FO) process. The PSA-coated MNPs demonstrated significantly higher osmotic pressure (~ 30 fold) as well as high FO water flux (~ 2–3 fold) when compared to their polymer (polyelectrolyte) counterpart, even at a very low concentration of ~ 0.13 wt.% in the draw solution. The PSA polymer chain conformation – coiled to extended – demonstrates a significant impact on the availability of the polymer hydrophilic groups in solution which is the driving force to attain higher osmotic pressure and water flux. When an optimum concentration of the polymer was anchored to a NP surface, the polymer chains assume an extended open conformation making the functional hydrophilic groups available to attract water molecules. This in turn boosts the osmotic pressure and FO water flux of the PSA-MNP draw agents. The low concentration of the PSA-MNP osmotic agent and the associated high water flux enhances the cost-effectiveness of our proposed SMDA system. In addition, easier magnetic separation and regeneration of the SMDA also improves its usability making it efficient, cost-effective and environment-friendly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been demonstrated that most cells of the body respond to osmotic pressure in a systematic manner. The disruption of the collagen network in the early stages of osteoarthritis causes an increase in water content of cartilage which leads to a reduction of pericellular osmolality in chondrocytes distributed within the extracellular environment. It is therefore arguable that an insight into the mechanical properties of chondrocytes under varying osmotic pressure would provide a better understanding of chondrocyte mechanotransduction and potentially contribute to knowledge on cartilage degeneration. In this present study, the chondrocyte cells were exposed to solutions with different osmolality. Changes in their dimensions and mechanical properties were measured over time. Atomic Force Microscopy (AFM) was used to apply load at various strain-rates and the force-time curves were logged. The thin-layer elastic model was used to extract the elastic stiffness of chondrocytes at different strain-rates and at different solution osmolality. In addition, the porohyperelastic (PHE) model was used to investigate the strain-rate dependent responses under the loading and osmotic pressure conditions. The results revealed that the hypo-osmotic external environment increased chondrocyte dimensions and reduced Young’s modulus of the cells at all strain-rates tested. In contrast, the hyper-osmotic external environment reduced dimensions and increased Young’s modulus. Moreover, by using the PHE model coupled with inverse FEA simulation, we established that the hydraulic permeability of chondrocytes increased with decreasing extracellular osmolality which is consistent with previous work in the literature. This could be due to a higher intracellular fluid volume fraction with lower osmolality.