677 resultados para non-Cartesian stimuli
em Queensland University of Technology - ePrints Archive
Resumo:
This paper describes an autonomous docking system and web interface that allows long-term unaided use of a sophisticated robot by untrained web users. These systems have been applied to the biologically inspired RatSLAM system as a foundation for testing both its long-term stability and its practicality. While docking and web interface systems already exist, this system allows for a significantly larger margin of error in docking accuracy due to the mechanical design, thereby increasing robustness against navigational errors. Also a standard vision sensor is used for both long-range and short-range docking, compared to the many systems that require both omni-directional cameras and high resolution Laser range finders for navigation. The web interface has been designed to accommodate the significant delays experienced on the Internet, and to facilitate the non- Cartesian operation of the RatSLAM system.
Resumo:
The Thatcher Illusion is generally discussed as a phenomenon related to face perception. Nonetheless, we show that compellingly strong Thatcher Effects can be elicited with non-face stimuli, provided that the stimulus set has a familiar standard configuration and a canonical view. Apparently, the Thatcher Illusion is not about faces, nor is it about Thatcher. It just might, however, be about Britain...
Resumo:
As a social species in a constantly changing environment, humans rely heavily on the informational richness and communicative capacity of the face. Thus, understanding how the brain processes information about faces in real-time is of paramount importance. The N170 is a high temporal resolution electrophysiological index of the brain's early response to visual stimuli that is reliably elicited in carefully controlled laboratory-based studies. Although the N170 has often been reported to be of greatest amplitude to faces, there has been debate regarding whether this effect might be an artifact of certain aspects of the controlled experimental stimulation schedules and materials. To investigate whether the N170 can be identified in more realistic conditions with highly variable and cluttered visual images and accompanying auditory stimuli we recorded EEG 'in the wild', while participants watched pop videos. Scene-cuts to faces generated a clear N170 response, and this was larger than the N170 to transitions where the videos cut to non-face stimuli. Within participants, wild-type face N170 amplitudes were moderately correlated to those observed in a typical laboratory experiment. Thus, we demonstrate that the face N170 is a robust and ecologically valid phenomenon and not an artifact arising as an unintended consequence of some property of the more typical laboratory paradigm.
Resumo:
While the neural regions associated with facial identity recognition are considered to be well defined, the neural correlates of non-moving and moving images of facial emotion processing are less clear. This study examined the brain electrical activity changes in 26 participants (14 males M = 21.64, SD = 3.99; 12 females M = 24.42, SD = 4.36), during a passive face viewing task, a scrambled face task and separate emotion and gender face discrimination tasks. The steady state visual evoked potential (SSVEP) was recorded from 64-electrode sites. Consistent with previous research, face related activity was evidenced at scalp regions over the parieto-temporal region approximately 170 ms after stimulus presentation. Results also identified different SSVEP spatio-temporal changes associated with the processing of static and dynamic facial emotions with respect to gender, with static stimuli predominately associated with an increase in inhibitory processing within the frontal region. Dynamic facial emotions were associated with changes in SSVEP response within the temporal region, which are proposed to index inhibitory processing. It is suggested that static images represent non-canonical stimuli which are processed via different mechanisms to their more ecologically valid dynamic counterparts.
Resumo:
In the present study we utilised functional magnetic resonance imaging (fMRI) to examine cerebral activation during performance of a classic motor task in which response suppression load was parametrically varied. Linear increases in activity were observed in a distributed network of regions across both cerebral hemispheres, although with more extensive involvement of the right prefrontal cortex. Activated regions included prefrontal, parietal and occipitotemporal cortices. Decreasing activation was similarly observed in a distributed network of regions. These response forms are discussed in terms of an increasing requirement for visual cue discrimination and suppression/selection of motor responses, and a decreasing probability of the occurrence of non-target stimuli and attenuation of a prepotent tendency to respond. The results support recent proposals for a dominant role for the right-hemisphere in performance of motor response suppression tasks that emphasise the importance of the right prefrontal cortex.
Resumo:
It has been proposed that body image disturbance is a form of cognitive bias wherein schemas for self-relevant information guide the selective processing of appearancerelated information in the environment. This threatening information receives disproportionately more attention and memory, as measured by an Emotional Stroop and incidental recall task. The aim of this thesis was to expand the literature on cognitive processing biases in non-clinical males and females by incorporating a number of significant methodological refinements. To achieve this aim, three phases of research were conducted. The initial two phases of research provided preliminary data to inform the development of the main study. Phase One was a qualitative exploration of body image concerns amongst males and females recruited through the general community and from a university. Seventeen participants (eight male; nine female) provided information on their body image and what factors they saw as positively and negatively impacting on their self evaluations. The importance of self esteem, mood, health and fitness, and recognition of the social ideal were identified as key themes. These themes were incorporated as psycho-social measures and Stroop word stimuli in subsequent phases of the research. Phase Two involved the selection and testing of stimuli to be used in the Emotional Stroop task. Six experimental categories of words were developed that reflected a broad range of health and body image concerns for males and females. These categories were high and low calorie food words, positive and negative appearance words, negative emotion words, and physical activity words. Phase Three addressed the central aim of the project by examining cognitive biases for body image information in empirically defined sub-groups. A National sample of males (N = 55) and females (N = 144), recruited from the general community and universities, completed an Emotional Stroop task, incidental memory test, and a collection of psycho-social questionnaires. Sub-groups of body image disturbance were sought using a cluster analysis, which identified three sub-groups in males (Normal, Dissatisfied, and Athletic) and four sub-groups in females (Normal, Health Conscious, Dissatisfied, and Symptomatic). No differences were noted between the groups in selective attention, although time taken to colour name the words was associated with some of the psycho-social variables. Memory biases found across the whole sample for negative emotion, low calorie food, and negative appearance words were interpreted as reflecting the current focus on health and stigma against being unattractive. Collectively these results have expanded our understanding of processing biases in the general community by demonstrating that the processing biases are found within non-clinical samples and that not all processing biases are associated with negative functionality
Resumo:
The tear film plays an important role preserving the health of the ocular surface and maintaining the optimal refractive power of the cornea. Moreover dry eye syndrome is one of the most commonly reported eye health problems. This syndrome is caused by abnormalities in the properties of the tear film. Current clinical tools to assess the tear film properties have shown certain limitations. The traditional invasive methods for the assessment of tear film quality, which are used by most clinicians, have been criticized for the lack of reliability and/or repeatability. A range of non-invasive methods of tear assessment have been investigated, but also present limitations. Hence no “gold standard” test is currently available to assess the tear film integrity. Therefore, improving techniques for the assessment of the tear film quality is of clinical significance and the main motivation for the work described in this thesis. In this study the tear film surface quality (TFSQ) changes were investigated by means of high-speed videokeratoscopy (HSV). In this technique, a set of concentric rings formed in an illuminated cone or a bowl is projected on the anterior cornea and their reflection from the ocular surface imaged on a charge-coupled device (CCD). The reflection of the light is produced in the outer most layer of the cornea, the tear film. Hence, when the tear film is smooth the reflected image presents a well structure pattern. In contrast, when the tear film surface presents irregularities, the pattern also becomes irregular due to the light scatter and deviation of the reflected light. The videokeratoscope provides an estimate of the corneal topography associated with each Placido disk image. Topographical estimates, which have been used in the past to quantify tear film changes, may not always be suitable for the evaluation of all the dynamic phases of the tear film. However the Placido disk image itself, which contains the reflected pattern, may be more appropriate to assess the tear film dynamics. A set of novel routines have been purposely developed to quantify the changes of the reflected pattern and to extract a time series estimate of the TFSQ from the video recording. The routine extracts from each frame of the video recording a maximized area of analysis. In this area a metric of the TFSQ is calculated. Initially two metrics based on the Gabor filter and Gaussian gradient-based techniques, were used to quantify the consistency of the pattern’s local orientation as a metric of TFSQ. These metrics have helped to demonstrate the applicability of HSV to assess the tear film, and the influence of contact lens wear on TFSQ. The results suggest that the dynamic-area analysis method of HSV was able to distinguish and quantify the subtle, but systematic degradation of tear film surface quality in the inter-blink interval in contact lens wear. It was also able to clearly show a difference between bare eye and contact lens wearing conditions. Thus, the HSV method appears to be a useful technique for quantitatively investigating the effects of contact lens wear on the TFSQ. Subsequently a larger clinical study was conducted to perform a comparison between HSV and two other non-invasive techniques, lateral shearing interferometry (LSI) and dynamic wavefront sensing (DWS). Of these non-invasive techniques, the HSV appeared to be the most precise method for measuring TFSQ, by virtue of its lower coefficient of variation. While the LSI appears to be the most sensitive method for analyzing the tear build-up time (TBUT). The capability of each of the non-invasive methods to discriminate dry eye from normal subjects was also investigated. The receiver operating characteristic (ROC) curves were calculated to assess the ability of each method to predict dry eye syndrome. The LSI technique gave the best results under both natural blinking conditions and in suppressed blinking conditions, which was closely followed by HSV. The DWS did not perform as well as LSI or HSV. The main limitation of the HSV technique, which was identified during the former clinical study, was the lack of the sensitivity to quantify the build-up/formation phase of the tear film cycle. For that reason an extra metric based on image transformation and block processing was proposed. In this metric, the area of analysis was transformed from Cartesian to Polar coordinates, converting the concentric circles pattern into a quasi-straight lines image in which a block statistics value was extracted. This metric has shown better sensitivity under low pattern disturbance as well as has improved the performance of the ROC curves. Additionally a theoretical study, based on ray-tracing techniques and topographical models of the tear film, was proposed to fully comprehend the HSV measurement and the instrument’s potential limitations. Of special interested was the assessment of the instrument’s sensitivity under subtle topographic changes. The theoretical simulations have helped to provide some understanding on the tear film dynamics, for instance the model extracted for the build-up phase has helped to provide some insight into the dynamics during this initial phase. Finally some aspects of the mathematical modeling of TFSQ time series have been reported in this thesis. Over the years, different functions have been used to model the time series as well as to extract the key clinical parameters (i.e., timing). Unfortunately those techniques to model the tear film time series do not simultaneously consider the underlying physiological mechanism and the parameter extraction methods. A set of guidelines are proposed to meet both criteria. Special attention was given to a commonly used fit, the polynomial function, and considerations to select the appropriate model order to ensure the true derivative of the signal is accurately represented. The work described in this thesis has shown the potential of using high-speed videokeratoscopy to assess tear film surface quality. A set of novel image and signal processing techniques have been proposed to quantify different aspects of the tear film assessment, analysis and modeling. The dynamic-area HSV has shown good performance in a broad range of conditions (i.e., contact lens, normal and dry eye subjects). As a result, this technique could be a useful clinical tool to assess tear film surface quality in the future.
Resumo:
This study investigated the Kinaesthetic Fusion Effect (KFE) first described by Craske and Kenny in 1981. The current study did not replicate these findings. Participants did not perceive any reduction in the sagittal separation of a button pressed by the index finger of one arm and a probe touching the other, following repeated exposure to the tactile stimuli present on both unseen arms. This study’s failure to replicate the widely-cited KFE as described by Craske et al. (1984) suggests that it may be contingent on several aspects of visual information, especially the availability of a specific visual reference, the role of instructions regarding gaze direction, and the potential use of a line of sight strategy when referring felt positions to an interposed surface. In addition, a foreshortening effect was found; this may result from a line-of-sight judgment and represent a feature of the reporting method used. The transformed line of sight data were regressed against the participant reported values, resulting in a slope of 1.14 (right arm) and 1.11 (left arm), and r > 0.997 for each. The study also provides additional evidence that mis-perceptions of the mediolateral position of the limbs specifically their separation and consistent with notions of Gestalt grouping, is somewhat labile and can be influenced by active motions causing touch of one limb by the other. Finally, this research will benefit future studies that require participants to report the perceived locations of the unseen limbs.
Resumo:
Neo-angiogenesis during neoplastic growth involves endothelial mitogenic and migration stimuli produced by cancer or tumour stromal cells. Although this active angiogenesis takes place in the tumour periphery, the process of vessel growth and survival in inner areas and its clinical role remain largely unexplored. The present study compared the microvessel score (MS) as well as the single endothelial cell score (ECS) in the invading edge and in inner areas of non-small cell lung carcinomas (NSCLCs). Three different patterns of vascular growth were distinguished: the edvin (edge vs. inner) type 1, where a low MS was observed in both peripheral and inner tumour areas; the edvin type 2, where a high MS was noted in the invading front but a low MS in inner areas; and the edvin type 3, where both peripheral and inner tumour areas had a high MS. The ECS was high in the invading edge in edvin type 2 and 3 cases and was sharply decreased in both types in inner areas, suggesting that endothelial cell migration is unlikely to contribute to the angiogenic process in areas away from the tumour front. Expression of the vascular endothelial growth factor (VEGF) and of thymidine phosphorylase (TP) was associated with a high MS in the invading edge. VEGF was associated with a high MS in inner areas (edvin 3), while TP expression was associated with edvin type 2, showing that VEGF (and not TP) contributes to the preservation of the inner vasculature. Both edvin type 2 and 3 cases showed an increased incidence of node metastasis, but edvin type 3 cases had a poorer prognosis, even in the N1-stage group. The present study suggests that tumour factors regulating angiogenesis and vascular survival are not identical. A possible method is reported to quantify these two parameters by comparing the MS in the invading edge and inner areas (edvin types). This observation may contribute to the evaluation of the effectiveness of different therapeutic approaches, namely vascular targeting vs. anti-angiogenesis. Copyright (C) 2000 John Wiley and Sons, Ltd.
Resumo:
The epidermal growth factor receptor (EGFR) is part of a family of plasma membrane receptor tyrosine kinases that control many important cellular functions, from growth and proliferation to cell death. Cyclooxygenase (COX)-2 is an enzyme which catalyses the conversion of arachidonic acid to prostagladins and thromboxane. It is induced by various inflammatory stimuli, including the pro-inflammatory cytokines, Interleukin (IL)-1β, Tumour Necrosis Factor (TNF)-α and IL-2. Both EGFR and COX-2 are over-expressed in non-small cell lung cancer (NSCLC) and have been implicated in the early stages of tumourigenesis. This paper considers their roles in the development and progression of lung cancer, their potential interactions, and reviews the recent progress in cancer therapies that are directed toward these targets. An increasing body of evidence suggests that selective inhibitors of both EGFR and COX-2 are potential therapeutic agents for the treatment of NSCLC, in the adjuvant, metastatic and chemopreventative settings. © 2002 Elsevier Science Ireland Ltd. All rights reserved.
Resumo:
Purpose There have been only a limited number of studies examining the accommodative response that occurs when the two eyes are provided with disparate accommodative stimuli, and the results from these studies to date have been equivocal. In this study, we therefore aimed to examine the capacity of the visual system to aniso-accommodate by objectively measuring the interocular difference in the accommodation response between fellow dominant and non-dominant eyes under controlled monocular and binocular viewing conditions during short-term exposure to aniso-accommodative stimuli. Methods The accommodative response of each eye of sixteen young isometropic adults (mean age 22 ± 2 years) with normal binocular vision was measured using an open-field autorefractor during a range of testing conditions; monocularly (accommodative demands ranging from 1.32 to 4.55 D) and binocularly while altering the accommodation demand for each eye (aniso-accommodative stimuli ranging from 0.24 to 2.05 D). Results Under monocular viewing conditions, the dominant and non-dominant eyes displayed a highly symmetric accommodative response; mean interocular difference in spherical equivalent 0.01 ± 0.06 D (relative) and 0.22 ± 0.06 D (absolute) (p>0.05). During binocular viewing, the dominant eye displayed a greater accommodative response (0.11 ± 0.34 D relative and 0.24 ± 0.26 D absolute) irrespective of whether the demand of the dominant or non-dominant eye was altered (p = 0.01). Astigmatic power vectors J0 and J45 did not vary between eyes or with increasing accommodation demands under monocular or binocular viewing conditions (p>0.05). Conclusion The dominant and non-dominant eyes of young isometropic individuals display a similar consensual lag of accommodation under both monocular and binocular viewing conditions, with the dominant eye showing a small but significantly greater (by 0.12 to 0.25 D) accommodative response. Evidence of short-term aniso-accommodation in response to asymmetric accommodation demands was not observed.