116 resultados para measure of non-exchangeability
em Queensland University of Technology - ePrints Archive
Resumo:
Hot and cold temperatures significantly increase mortality rates around the world, but which measure of temperature is the best predictor of mortality is not known. We used mortality data from 107 US cities for the years 1987–2000 and examined the association between temperature and mortality using Poisson regression and modelled a non-linear temperature effect and a non-linear lag structure. We examined mean, minimum and maximum temperature with and without humidity, and apparent temperature and the Humidex. The best measure was defined as that with the minimum cross-validated residual. We found large differences in the best temperature measure between age groups, seasons and cities, and there was no one temperature measure that was superior to the others. The strong correlation between different measures of temperature means that, on average, they have the same predictive ability. The best temperature measure for new studies can be chosen based on practical concerns, such as choosing the measure with the least amount of missing data.
Resumo:
The modern society has come to expect the electrical energy on demand, while many of the facilities in power systems are aging beyond repair and maintenance. The risk of failure is increasing with the aging equipments and can pose serious consequences for continuity of electricity supply. As the equipments used in high voltage power networks are very expensive, economically it may not be feasible to purchase and store spares in a warehouse for extended periods of time. On the other hand, there is normally a significant time before receiving equipment once it is ordered. This situation has created a considerable interest in the evaluation and application of probability methods for aging plant and provisions of spares in bulk supply networks, and can be of particular importance for substations. Quantitative adequacy assessment of substation and sub-transmission power systems is generally done using a contingency enumeration approach which includes the evaluation of contingencies, classification of the contingencies based on selected failure criteria. The problem is very complex because of the need to include detailed modelling and operation of substation and sub-transmission equipment using network flow evaluation and to consider multiple levels of component failures. In this thesis a new model associated with aging equipment is developed to combine the standard tools of random failures, as well as specific model for aging failures. This technique is applied in this thesis to include and examine the impact of aging equipments on system reliability of bulk supply loads and consumers in distribution network for defined range of planning years. The power system risk indices depend on many factors such as the actual physical network configuration and operation, aging conditions of the equipment, and the relevant constraints. The impact and importance of equipment reliability on power system risk indices in a network with aging facilities contains valuable information for utilities to better understand network performance and the weak links in the system. In this thesis, algorithms are developed to measure the contribution of individual equipment to the power system risk indices, as part of the novel risk analysis tool. A new cost worth approach was developed in this thesis that can make an early decision in planning for replacement activities concerning non-repairable aging components, in order to maintain a system reliability performance which economically is acceptable. The concepts, techniques and procedures developed in this thesis are illustrated numerically using published test systems. It is believed that the methods and approaches presented, substantially improve the accuracy of risk predictions by explicit consideration of the effect of equipment entering a period of increased risk of a non-repairable failure.
Resumo:
The Environmental Kuznets Curve (EKC) hypothesises an inverse U-shaped relationship between a measure of environmental pollution and per capita income levels. In this study, we apply non-parametric estimation of local polynomial regression (local quadratic fitting) to allow more flexibility in local estimation. This study uses a larger and globally representative sample of many local and global pollutants and natural resources including Biological Oxygen Demand (BOD) emission, CO2 emission, CO2 damage, energy use, energy depletion, mineral depletion, improved water source, PM10, particulate emission damage, forest area and net forest depletion. Copyright © 2009 Inderscience Enterprises Ltd.
Resumo:
Objectives To compare the efficacy of two exercise programs in reducing pain and disability for individuals with non-specific low back pain and to examine the underlying mechanical factors related to pain and disability for individuals with NSLBP. Design A single-blind, randomized controlled trial. Methods: Eighty participants were recruited from eleven community-based general medical practices and randomized into two groups completing either a lumbopelvic motor control or a combined lumbopelvic motor control and progressive hip strengthening exercise therapy program. All participants received an education session, 6 rehabilitation sessions including real time ultrasound training, and a home based exercise program manual and log book. The primary outcomes were pain (0-100mm visual analogue scale), and disability (Oswestry Disability Index V2). The secondary outcomes were hip strength (N/kg) and two-dimensional frontal plane biomechanics (°) measure during the static Trendelenburg test and while walking. All outcomes were measured at baseline and at 6-week follow up. Results There was no statistical difference in the change in pain (xˉ = -4.0mm, t= -1.07, p =0.29, 95%CI -11.5, 3.5) or disability (xˉ = -0.3%, t= -0.19, p =0.85, 95%CI -3.5, 2.8) between groups. Within group comparisons revealed clinically meaningful reductions in pain for both Group One (xˉ =-20.9mm, 95%CI -25.7, -16.1) and Group Two (xˉ =-24.9, 95%CI -30.8, -19.0). Conclusion Both exercise programs had similar efficacy in reducing pain. The addition of hip strengthening exercises to a motor control exercise program does not appear to result in improved clinical outcome for pain for individuals with non-specific low back pain.
Resumo:
Background Sedentary behaviour is associated with several deleterious health consequences. Although device-based measures of sedentary time are available, they are costly and do not provide a measure of domain specific sedentary time. High quality self-report measures are necessary to accurately capture domain specific sedentary time, and to provide an alternative to devices when cost is an issue. In this study, the Past-day Adults’ Sedentary Time (PAST) questionnaire, previously shown to have acceptable validity and reliability in a sample of breast cancer survivors, was modified for a university sample and validity of the modified questionnaire was examined compared with activPAL. Methods Participants (n = 58, age = 18–55 years, 48% female, 66% students) were recruited from the University of Queensland (students and staff). They answered the PAST questionnaire, which asked about time spent sitting or lying down for work, study, travel, television viewing, leisure-time computer use, reading, eating, socialising and other purposes, during the previous day. Time reported for these questions was summed to provide a measure of total sedentary time. Participants also wore an activPAL device for the full day prior to completing the questionnaire and recorded their wake and sleep times in an activity log. Total waking sedentary time derived from the activPAL was used as the criterion measure. Correlation (Pearson's r) and agreement (Bland–Altman plots) between PAST and activPAL sedentary time were examined. Results Participants were sedentary (activPAL-determined) for approximately 66% of waking hours. The correlation between PAST and activPAL sedentary time for the whole sample was r = 0.50 [95% confidence interval (CI) = 0.28–0.67]; and higher for non-students (r = 0.63, 95% CI = 0.26–0.84) than students (r = 0.46, 95% CI = 0.16–0.68). Bland–Altman plots revealed that the mean difference between the two measures was 19 min although limits of agreement were wide (95% limits of agreement −4.1 to 4.7 h). Discussion The PAST questionnaire provides an acceptable measure of sedentary time in this population, which included students and adults with high workplace sitting. These findings support earlier research that questionnaires employing past-day recall of sedentary time provide a viable alternative to existing sedentary behaviour questionnaires.
Complex Impedance Measurement During RF Catheter Ablation: A More Accurate Measure of Power Delivery