201 resultados para four-stroke

em Queensland University of Technology - ePrints Archive


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The current investigation reports on diesel particulate matter emissions, with special interest in fine particles from the combustion of two base fuels. The base fuels selected were diesel fuel and marine gas oil (MGO). The experiments were conducted with a four-stroke, six-cylinder, direct injection diesel engine. The results showed that the fine particle number emissions measured by both SMPS and ELPI were higher with MGO compared to diesel fuel. It was observed that the fine particle number emissions with the two base fuels were quantitatively different but qualitatively similar. The gravimetric (mass basis) measurement also showed higher total particulate matter (TPM) emissions with the MGO. The smoke emissions, which were part of TPM, were also higher for the MGO. No significant changes in the mass flow rate of fuel and the brake-specific fuel consumption (BSFC) were observed between the two base fuels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper quantifies the mixing and dispersion from an outboard motor by field experiments in a small subtropical waterway. Organic dye was used as a surrogate for exhaust emissions and was mixed with uncontaminated creek water before being dispersed into the creek. Dye concentrations were measured with an array of concentration probes stationed in the creek. The data were then processed and fitted with a power law function. The corresponding dispersion constants agreed well with the literature. However, the amplitude was lower than the IMO equation but higher than the correlation from laboratory tests. Results for dye concentration intermittency (presence of dye) are presented for the first time from such field measurements and show significant mixing in-homogeneity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Continuous monitoring of diesel engine performance is critical for early detection of fault developments in an engine before they materialize into a functional failure. Instantaneous crank angular speed (IAS) analysis is one of a few nonintrusive condition monitoring techniques that can be utilized for such a task. Furthermore, the technique is more suitable for mass industry deployments than other non-intrusive methods such as vibration and acoustic emission techniques due to the low instrumentation cost, smaller data size and robust signal clarity since IAS is not affected by the engine operation noise and noise from the surrounding environment. A combination of IAS and order analysis was employed in this experimental study and the major order component of the IAS spectrum was used for engine loading estimation and fault diagnosis of a four-stroke four-cylinder diesel engine. It was shown that IAS analysis can provide useful information about engine speed variation caused by changing piston momentum and crankshaft acceleration during the engine combustion process. It was also found that the major order component of the IAS spectra directly associated with the engine firing frequency (at twice the mean shaft rotating speed) can be utilized to estimate engine loading condition regardless of whether the engine is operating at healthy condition or with faults. The amplitude of this order component follows a distinctive exponential curve as the loading condition changes. A mathematical relationship was then established in the paper to estimate the engine power output based on the amplitude of this order component of the IAS spectrum. It was further illustrated that IAS technique can be employed for the detection of a simulated exhaust valve fault in this study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an experimental study on the vibration signal patterns associated with a simulated piston slap test of a four-cylinder diesel engine. It is found that a simulated worn-off piston results in an increase in vibration RMS peak amplitudes associated with the major mechanical events of the corresponding cylinder (i.e., inlet and exhaust valve closing and combustion of Cylinder 1). This then led to an increase of overall vibration amplitude of the time domain statistical features such as RMS, Crest Factor, Skewness and Kurtosis in all loading conditions. The simulated worn-off piston not only increased the impact amplitude of piston slap during the engine combustion, it also produced a distinct impulse response during the air induction stroke of the cylinder attributing to an increase of lateral impact force as a result of piston reciprocating motion and the increased clearance between the worn-off piston and the cylinder. The unique signal patterns of piston slap disclosed in this paper can be utilized to assist in the development of condition monitoring tools for automated diagnosis of similar diesel engine faults in practical applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Individuals who experience stroke have a higher likelihood of subsequent stroke events, making it imperative to plan for future medical care. In the event of a further serious health event, engaging in the process of advanced care planning (ACP) can help family members and health care professionals (HCPs) make medical decisions for individuals who have lost the capacity to do so. Few studies have explored the views and experiences of patients with stroke about discussing their wishes and preferences for future medical events, and the extent to which stroke HCPs engage in conversations around planning for such events. In this study, we sought to understand how the process of ACP unfolded between HCPs and patients post-stroke. Patients and methods Using grounded theory (GT) methodology, we engaged in direct observation of HCP and patient interactions on an acute stroke unit and two stroke rehabilitation units. Using semi-structured interviews, 14 patients and four HCPs were interviewed directly about the ACP process. Results We found that open and continual ACP conversations were not taking place, patients experienced an apparent lack of urgency to engage in ACP, and HCPs were uncomfortable initiating ACP conversations due to the sensitive nature of the topic. Conclusion In this study, we identified lack of engagement in ACP post-stroke, attributable to patient and HCP factors. This encourages us to look further into the process of ACP in order to develop open communication between the patient with stroke, their families, and stroke HCPs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Title The trajectory of minor stroke recovery for men and their female spousal caregivers: literature review Aim This paper is a report of a narrative review to examine the current state of knowledge regarding the impact of minor stroke on male patients and their female spousal caregivers’ recovery trajectory and quality of life. Background Minor stroke survivors are often discharged early in the recovery process. The perception of the healthcare community that these patients and their female spousal caregivers will experience an uneventful recovery may lead to inadequate preparation for the postdischarge period. Methods A range of databases was searched to identify papers addressing ‘minor stroke’, ‘transitions’, ‘quality of life’, ‘chronic disease’, ‘caregivers’ and ‘spouse caregivers’, including AARP Ageline, AMED, CINAHL, Evidence Based Medicine Reviews, MEDLINE and PsychInfo. Papers published in English from 1990 to December 2006 were included. Thirty-four papers were in the final data set. Results Minor stroke survivors and their female spousal caregivers may experience major challenges in adaptations postdischarge. The trajectory of minor stroke recovery may necessitate a re-evaluation of life plans, rethinking of priorities and integration of resulting disabilities into current and emerging life situations for both stroke survivors and their female spousal caregivers. In many cases these adaptations are compounded by transitions associated with the normal ageing process. Conclusion While there is extensive literature on stroke recovery and the role of caregivers in general, there is little available describing the recovery of minor stroke survivors in relation to the normal ageing process. Further research is needed examining recovery from a transitional perspective, to support nurses and other health professionals discharge planning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Genetic factors have been implicated in stroke risk, but few replicated associations have been reported. We conducted a genome-wide association study (GWAS) for ischemic stroke and its subtypes in 3,548 affected individuals and 5,972 controls, all of European ancestry. Replication of potential signals was performed in 5,859 affected individuals and 6,281 controls. We replicated previous associations for cardioembolic stroke near PITX2 and ZFHX3 and for large vessel stroke at a 9p21 locus. We identified a new association for large vessel stroke within HDAC9 (encoding histone deacetylase 9) on chromosome 7p21.1 (including further replication in an additional 735 affected individuals and 28,583 controls) (rs11984041; combined P = 1.87 × 10 -11; odds ratio (OR) = 1.42, 95% confidence interval (CI) = 1.28-1.57). All four loci exhibited evidence for heterogeneity of effect across the stroke subtypes, with some and possibly all affecting risk for only one subtype. This suggests distinct genetic architectures for different stroke subtypes.