7 resultados para femtosecond laser pulse

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigated the influence of different gas environments on the fabrication of surfaces, homogeneously covered with equally sized and spaced micro-structures. Two types of structures have been successfully micro-machined with a femtosecond laser on titanium surfaces in various atmospheres. The surface chemistry of samples machined in oxygen and helium shows TiO2, while machining in nitrogen leads to an additional share of TiN. The actual surface structure was found to vary significantly as a function of the gas environment. We found that the ablated particles and their surface triggered two consecutive events: The optical properties of the gas environment became non-isotropic which then led to the pulse intensity being redistributed throughout the cross section of the laser beam. Additionally, the effective intensity was further reduced for TiN surfaces due to TiN's high reflectivity. Thus, the settings for the applied raster-scanning machining method had to be adjusted for each gas environment to produce comparable structures. In contrast to previous studies, where only noble gases were found suitable to produce homogeneous patches, we obtained them in an oxygen environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Wavefront-guided Laser-assisted in situ keratomileusis (LASIK) is a widespread and effective surgical treatment for myopia and astigmatic correction but whether it induces higher-order aberrations remains controversial. The study was designed to evaluate the changes in higher-order aberrations after wavefront-guided ablation with IntraLase femtosecond laser in moderate to high astigmatism. Methods Twenty-three eyes of 15 patients with moderate to high astigmatism (mean cylinder, −3.22 ± 0.59 dioptres) aged between 19 and 35 years (mean age, 25.6 ± 4.9 years) were included in this prospective study. Subjects with cylinder ≥ 1.5 and ≤2.75 D were classified as moderate astigmatism while high astigmatism was ≥3.00 D. All patients underwent a femtosecond laser–enabled (150-kHz IntraLase iFS; Abbott Medical Optics Inc) wavefront-guided ablation. Uncorrected (UDVA), corrected (CDVA) distance visual acuity in logMAR, keratometry, central corneal thickness (CCT) and higher-order aberrations (HOAs) over a 6 mm pupil, were assessed before and 6 months, postoperatively. The relationship between postoperative change in HOA and preoperative mean spherical equivalent refraction, mean astigmatism, and postoperative CCT were tested. Results At the last follow-up, the mean UDVA was increased (P < 0.0001) but CDVA remained unchanged (P = 0.48) and no eyes lost ≥2 lines of CDVA. Mean spherical equivalent refraction was reduced (P < 0.0001) and was within ±0.50 D range in 61 % of eyes. The average corneal curvature was flatter by 4 D and CCT was reduced by 83 μm (P < 0.0001, for all), postoperatively. Coma aberrations remained unchanged (P = 0.07) while the change in trefoil (P = 0.047) postoperatively, was not clinically significant. The 4th order HOAs (spherical aberration and secondary astigmatism) and the HOA root mean square (RMS) increased from −0.18 ± 0.07 μm, 0.04 ± 0.03 μm and 0.47 ± 0.11 μm, preoperatively, to 0.33 ± 0.19 μm (P = 0.004), 0.21 ± 0.09 μm (P < 0.0001) and 0.77 ± 0.27 μm (P < 0.0001), six months postoperatively. The change in spherical aberration after the procedure increased with an increase in the degree of preoperative myopia. Conclusions Wavefront-guided IntraLASIK offers a safe and effective option for vision and visual function improvement in astigmatism. Although, reduction of HOA is possible in a few eyes, spherical-like aberrations are increased in majority of the treated eyes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Linewidth measurement of a femtosecond laser direct-written distributed feedback (DFB) waveguide laser (WGL) is reported. The WGL was fabricated in Yb-doped phosphate glass using the femtosecond laser direct-write technique. The linewidth was measured using a loss-compensated recirculating delayed self-heterodyne interferometer. By recirculating the output signal in a 10.2-km fiber delay loop, the linewidth was measured to be 35.4±1.4 kHz at a delay time of 306 μs , which is comparable with that of narrow-linewidth fiber DFB lasers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel gold coated femtosecond laser nanostructured sapphire surface – an “optical nose” - based on surface-enhanced Raman spectroscopy (SERS) for detecting vapours of explosive substances was investigated. Four different nitroaromatic vapours at room temperature were tested. Sensor responses were unambiguous and showed response in the range of 0.05 – 15 uM at 25 °C. The laser fabricated substrate nanostructures produced up to an eight-fold increase in Raman signal over that observed on the unstructured portions of the substrate. This work demonstrates a simple sensing system that is compatible with commercial manufacturing practices to detect taggants in explosives which can undertake as part of an integrated security or investigative mission.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Radical-directed dissociation of gas phase ions is emerging as a powerful and complementary alternative to traditional tandem mass spectrometric techniques for biomolecular structural analysis. Previous studies have identified that coupling of 2-[(2,2,6,6-tetramethylpiperidin-1-oxyl)methyl] benzoic acid (TEMPO-Bz) to the N-terminus of a peptide introduces a labile oxygen-carbon bond that can be selectively activated upon collisional activation to produce a radical ion. Here we demonstrate that structurally-defined peptide radical ions can also be generated upon UV laser photodissociation of the same TEMPO-Bz derivatives in a linear ion-trap mass spectrometer. When subjected to further mass spectrometric analyses, the radical ions formed by a single laser pulse undergo identical dissociations as those formed by collisional activation of the same precursor ion, and can thus be used to derive molecular structure. Mapping the initial radical formation process as a function of photon energy by photodissociation action spectroscopy reveals that photoproduct formation is selective but occurs only in modest yield across the wavelength range (300-220 nm), with the photoproduct yield maximised between 235 and 225 nm. Based on the analysis of a set of model compounds, structural modifications to the TEMPO-Bz derivative are suggested to optimise radical photoproduct yield. Future development of such probes offers the advantage of increased sensitivity and selectivity for radical-directed dissociation. © 2014 the Owner Societies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE - To present the results of same-day topography-guided photorefractive keratectomy (TG-PRK) and corneal collagen cross-linking (CXL) after intrastromal corneal ring (ISCR) implantation in patients with keratoconus. METHODS - Thirty-three patients (41 eyes) aged between 19 and 45 years were included in this prospective study. All patients underwent a femtosecond laser-enabled (Intralase FS; Abbott Medical Optics, Inc.) placement of intracorneal ring segments (Kerarings; Mediphacos, Brazil). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and keratometry readings remained stable for 6 months. Same-day PRK and CXL was subsequently performed in all patients. RESULTS - After 12 months of completion of the procedure, mean UDVA in log of minimal angle of resolution was significantly improved (0.74±0.54-0.10±0.16); CDVA did not improve significantly but 85% of eyes maintained or gained multiple lines of CDVA; mean refraction spherical equivalent improved (from -3.03±1.98 to -0.04±0.99 D), all keratometry readings were significantly reduced, from preoperative values, but coma did not vary significantly from preoperative values. Central corneal thickness and corneal thickness at the thinnest point were significantly (P<0.0001) reduced from 519.76±29.33 and 501.87±31.50 preoperatively to 464.71±36.79 and 436.55±47.42 postoperatively, respectively. Safety and efficacy indices were 0.97 and 0.88, respectively. From 6 months up until more than 1 year of follow-up, further significant improvement was observed only for UDVA (P<0.0001). CONCLUSIONS - Same-day combined TG-PRK and CXL after ISCR implantation is a safe and effective option for improving visual acuity and visual function, and it halts the progression of the keratoconus. The improvements recorded after 6 months of follow-up were maintained or improved upon 1 year after the procedure.