272 resultados para computed tomographic scan artifact, false positive, facet subluxation

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

- Background In the UK, women aged 50–73 years are invited for screening by mammography every 3 years. In 2009–10, more than 2.24 million women in this age group in England were invited to take part in the programme, of whom 73% attended a screening clinic. Of these, 64,104 women were recalled for assessment. Of those recalled, 81% did not have breast cancer; these women are described as having a false-positive mammogram. - Objective The aim of this systematic review was to identify the psychological impact on women of false-positive screening mammograms and any evidence for the effectiveness of interventions designed to reduce this impact. We were also looking for evidence of effects in subgroups of women. - Data sources MEDLINE, MEDLINE In-Process & Other Non-Indexed Citations, EMBASE, Health Management Information Consortium, Cochrane Central Register for Controlled Trials, Cochrane Database of Systematic Reviews, Centre for Reviews and Dissemination (CRD) Database of Abstracts of Reviews of Effects, CRD Health Technology Assessment (HTA), Cochrane Methodology, Web of Science, Science Citation Index, Social Sciences Citation Index, Conference Proceedings Citation Index-Science, Conference Proceeding Citation Index-Social Science and Humanities, PsycINFO, Cumulative Index to Nursing and Allied Health Literature, Sociological Abstracts, the International Bibliography of the Social Sciences, the British Library's Electronic Table of Contents and others. Initial searches were carried out between 8 October 2010 and 25 January 2011. Update searches were carried out on 26 October 2011 and 23 March 2012. - Review methods Based on the inclusion criteria, titles and abstracts were screened independently by two reviewers. Retrieved papers were reviewed and selected using the same independent process. Data were extracted by one reviewer and checked by another. Each included study was assessed for risk of bias. - Results Eleven studies were found from 4423 titles and abstracts. Studies that used disease-specific measures found a negative psychological impact lasting up to 3 years. Distress increased with the level of invasiveness of the assessment procedure. Studies using instruments designed to detect clinical levels of morbidity did not find this effect. Women with false-positive mammograms were less likely to return for the next round of screening [relative risk (RR) 0.97; 95% confidence interval (CI) 0.96 to 0.98] than those with normal mammograms, were more likely to have interval cancer [odds ratio (OR) 3.19 (95% CI 2.34 to 4.35)] and were more likely to have cancer detected at the next screening round [OR 2.15 (95% CI 1.55 to 2.98)]. - Limitations This study was limited to UK research and by the robustness of the included studies, which frequently failed to report quality indicators, for example failure to consider the risk of bias or confounding, or failure to report participants' demographic characteristics. - Conclusions We conclude that the experience of having a false-positive screening mammogram can cause breast cancer-specific psychological distress that may endure for up to 3 years, and reduce the likelihood that women will return for their next round of mammography screening. These results should be treated cautiously owing to inherent weakness of observational designs and weaknesses in reporting. Future research should include a qualitative interview study and observational studies that compare generic and disease-specific measures, collect demographic data and include women from different social and ethnic groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

- Objectives To identify the psychological effects of false-positive screening mammograms in the UK. - Methods Systematic review of all controlled studies and qualitative studies of women with a false-positive screening mammogram. The control group participants had normal mammograms. All psychological outcomes including returning for routine screening were permitted. All studies had a narrative synthesis. - Results The searches returned seven includable studies (7/4423). Heterogeneity was such that meta-analysis was not possible. Studies using disease-specific measures found that, compared to normal results, there could be enduring psychological distress that lasted up to 3 years; the level of distress was related to the degree of invasiveness of the assessment. At 3 years the relative risks were, further mammography, 1.28 (95% CI 0.82 to 2.00), fine needle aspiration 1.80 (95% CI 1.17 to 2.77), biopsy 2.07 (95% CI 1.22 to 3.52) and early recall 1.82 (95% CI 1.22 to 2.72). Studies that used generic measures of anxiety and depression found no such impact up to 3 months after screening. Evidence suggests that women with false-positive mammograms have an increased likelihood of failing to reattend for routine screening, relative risk 0.97 (95% CI 0.96 to 0.98) compared with women with normal mammograms. - Conclusions Having a false-positive screening mammogram can cause breast cancer-specific distress for up to 3 years. The degree of distress is related to the invasiveness of the assessment. Women with false-positive mammograms are less likely to return for routine assessment than those with normal ones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study Design. A sheep study designed to compare the accuracy of static radiographs, dynamic radiographs, and computed tomographic (CT) scans for the assessment of thoracolumbar facet joint fusion as determined by micro-CT scanning. Objective. To determine the accuracy and reliability of conventional imaging techniques in identifying the status of thoracolumbar (T13-L1) facet joint fusion in a sheep model. Summary of Background Data. Plain radiographs are commonly used to determine the integrity of surgical arthrodesis of the thoracolumbar spine. Many previous studies of fusion success have relied solely on postoperative assessment of plain radiographs, a technique lacking sensitivity for pseudarthrosis. CT may be a more reliable technique, but is less well characterized. Methods. Eleven adult sheep were randomized to either attempted arthrodesis using autogenous bone graft and internal fixation (n = 3) or intentional pseudarthrosis (IP) using oxidized cellulose and internal fixation (n = 8). After 6 months, facet joint fusion was assessed by independent observers, using (1) plain static radiography alone, (2) additional dynamic radiographs, and (3) additional reconstructed spiral CT imaging. These assessments were correlated with high-resolution micro-CT imaging to predict the utility of the conventional imaging techniques in the estimation of fusion success. Results. The capacity of plain radiography alone to correctly predict fusion or pseudarthrosis was 43% and was not improved using plain radiography and dynamic radiography with also a 43% accuracy. Adding assessment by reformatted CT imaging to the plain radiography techniques increased the capacity to predict fusion outcome to 86% correctly. The sensitivity, specificity, and accuracy of static radiography were 0.33, 0.55, and 0.43, respectively, those of dynamic radiography were 0.46, 0.40, and 0.43, respectively, and those of radiography plus CT were 0.88, 0.85, and 0.86, respectively. Conclusion. CT-based evaluation correlated most closely with high-resolution micro-CT imaging. Neither plain static nor dynamic radiographs were able to predict fusion outcome accurately. © 2012 Lippincott Williams & Wilkins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an efficient face detection method suitable for real-time surveillance applications. Improved efficiency is achieved by constraining the search window of an AdaBoost face detector to pre-selected regions. Firstly, the proposed method takes a sparse grid of sample pixels from the image to reduce whole image scan time. A fusion of foreground segmentation and skin colour segmentation is then used to select candidate face regions. Finally, a classifier-based face detector is applied only to selected regions to verify the presence of a face (the Viola-Jones detector is used in this paper). The proposed system is evaluated using 640 x 480 pixels test images and compared with other relevant methods. Experimental results show that the proposed method reduces the detection time to 42 ms, where the Viola-Jones detector alone requires 565 ms (on a desktop processor). This improvement makes the face detector suitable for real-time applications. Furthermore, the proposed method requires 50% of the computation time of the best competing method, while reducing the false positive rate by 3.2% and maintaining the same hit rate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A major challenge in neuroscience is finding which genes affect brain integrity, connectivity, and intellectual function. Discovering influential genes holds vast promise for neuroscience, but typical genome-wide searches assess approximately one million genetic variants one-by-one, leading to intractable false positive rates, even with vast samples of subjects. Even more intractable is the question of which genes interact and how they work together to affect brain connectivity. Here, we report a novel approach that discovers which genes contribute to brain wiring and fiber integrity at all pairs of points in a brain scan. We studied genetic correlations between thousands of points in human brain images from 472 twins and their nontwin siblings (mean age: 23.7 2.1 SD years; 193 male/279 female).Wecombined clustering with genome-wide scanning to find brain systems withcommongenetic determination.Wethen filtered the image in a new way to boost power to find causal genes. Using network analysis, we found a network of genes that affect brain wiring in healthy young adults. Our new strategy makes it computationally more tractable to discover genes that affect brain integrity. The gene network showed small-world and scale-free topologies, suggesting efficiency in genetic interactions and resilience to network disruption. Genetic variants at hubs of the network influence intellectual performance by modulating associations between performance intelligence quotient and the integrity of major white matter tracts, such as the callosal genu and splenium, cingulum, optic radiations, and the superior longitudinal fasciculus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Copy number variants (CNVs) account for a major proportion of human genetic polymorphism and have been predicted to have an important role in genetic susceptibility to common disease. To address this we undertook a large, direct genome-wide study of association between CNVs and eight common human diseases. Using a purpose-designed array we typed 19,000 individuals into distinct copy-number classes at 3,432 polymorphic CNVs, including an estimated 50% of all common CNVs larger than 500 base pairs. We identified several biological artefacts that lead to false-positive associations, including systematic CNV differences between DNAs derived from blood and cell lines. Association testing and follow-up replication analyses confirmed three loci where CNVs were associated with diseaseIRGM for Crohns disease, HLA for Crohns disease, rheumatoid arthritis and type 1 diabetes, and TSPAN8 for type 2 diabetesalthough in each case the locus had previously been identified in single nucleotide polymorphism (SNP)-based studies, reflecting our observation that most common CNVs that are well-typed on our array are well tagged by SNPs and so have been indirectly explored through SNP studies. We conclude that common CNVs that can be typed on existing platforms are unlikely to contribute greatly to the genetic basis of common human diseases. © 2010 Macmillan Publishers Limited. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Increased biomechanical stresses within the abdominal aortic aneurysm (AAA) wall contribute to its rupture. Calcification and intraluminal thrombus can be commonly found in AAAs, but the relationship between calcification/intraluminal thrombus and AAA wall stress is not completely described. Methods: Patient-specific three-dimensional AAA geometries were reconstructed from computed tomographic images of 20 patients. Structural analysis was performed to calculate the wall stresses of the 20 AAA models and their altered models when calcification or intraluminal thrombus was not considered. A nonlinear large-strain finite element method was used to compute the wall stress distribution. The relationships between wall stresses and volumes of calcification and intraluminal thrombus were sought. Results: Maximum stress was not correlated with the percentage of calcification, and was negatively correlated with the percentage of intraluminal thrombus (r = -0.56; P = .011). Exclusion of calcification from analysis led to a significant decrease in maximum stress by a median of 14% (range, 2%-27%; P < .01). When intraluminal thrombus was eliminated, maximum stress increased significantly by a median of 24% (range, 5%-43%; P < .01). Conclusion: The presence of calcification increases AAA peak wall stress, suggesting that calcification decrease the biomechanical stability of AAA. In contrast, intraluminal thrombus reduces the maximum stress in AAA. Calcification and intraluminal thrombus should both be considered in the evaluation of wall stress for risk assessment of AAA rupture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study Design Retrospective review of prospectively collected data. Objectives To analyze intervertebral (IV) fusion after thoracoscopic anterior spinal fusion (TASF) and explore the relationship between fusion scores and key clinical variables. Summary of Background Information TASF provides comparable correction with some advantages over posterior approaches but reported mechanical complications, and their relationship to non-union and graft material is unclear. Similarly, the optimal combination of graft type and implant stiffness for effecting successful radiologic union remains undetermined. Methods A subset of patients from a large single-center series who had TASF for progressive scoliosis underwent low-dose computed tomographic scans 2 years after surgery. The IV fusion mass in the disc space was assessed using the 4-point Sucato scale, where 1 indicates <50% and 4 indicates 100% bony fusion of the disc space. The effects of rod diameter, rod material, graft type, fusion level, and mechanical complications on fusion scores were assessed. Results Forty-three patients with right thoracic major curves (mean age 14.9 years) participated in the study. Mean fusion scores for patient subgroups ranged from 1.0 (IV levels with rod fractures) to 2.2 (4.5-mm rod with allograft), with scores tending to decrease with increasing rod size and stiffness. Graft type (autograft vs. allograft) did not affect fusion scores. Fusion scores were highest in the middle levels of the rod construct (mean 2.52), dropping off by 20% to 30% toward the upper and lower extremities of the rod. IV levels where a rod fractured had lower overall mean fusion scores compared to levels without a fracture. Mean total Scoliosis Research Society (SRS) questionnaire scores were 98.9 from a possible total of 120, indicating a good level of patient satisfaction. Conclusions Results suggest that 100% radiologic fusion of the entire disc space is not necessary for successful clinical outcomes following thoracoscopic anterior selective thoracic fusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare the effectiveness of the STRATIFY falls tool with nurses’ clinical judgments in predicting patient falls. Study Design and Setting: A prospective cohort study was conducted among the inpatients of an acute tertiary hospital. Participants were patients over 65 years of age admitted to any hospital unit. Sensitivity, specificity, and positive predictive value (PPV) and negative predictive values (NPV) of the instrument and nurses’ clinical judgments in predicting falls were calculated. Results: Seven hundred and eighty-eight patients were screened and followed up during the study period. The fall prevalence was 9.2%. Of the 335 patients classified as being ‘‘at risk’’ for falling using the STRATIFY tool, 59 (17.6%) did sustain a fall (sensitivity50.82, specificity50.61, PPV50.18, NPV50.97). Nurses judged that 501 patients were at risk of falling and, of these, 60 (12.0%) fell (sensitivity50.84, specificity50.38, PPV50.12, NPV50.96). The STRATIFY tool correctly identified significantly more patients as either fallers or nonfallers than the nurses (P50.027). Conclusion: Considering the poor specificity and high rates of false-positive results for both the STRATIFY tool and nurses’ clinical judgments, we conclude that neither of these approaches are useful for screening of falls in acute hospital settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bioactive and bioresorbable scaffold fabricated from medical grade poly (epsilon-caprolactone) and incorporating 20% beta-tricalcium phosphate (mPCL–TCP) was recently developed for bone regeneration at load bearing sites. In the present study, we aimed to evaluate bone ingrowth into mPCL–TCP in a large animal model of lumbar interbody fusion. Six pigs underwent a 2-level (L3/4; L5/6) anterior lumbar interbody fusion (ALIF) implanted with mPCL–TCP þ 0.6 mg rhBMP-2 as treatment group while four other pigs implanted with autogenous bone graft served as control. Computed tomographic scanning and histology revealed complete defect bridging in all (100%) specimen from the treatment group as early as 3 months. Histological evidence of continuing bone remodeling and maturation was observed at 6 months. In the control group, only partial bridging was observed at 3 months and only 50% of segments in this group showed complete defect bridging at 6 months. Furthermore, 25% of segments in the control group showed evidence of graft fracture, resorption and pseudoarthrosis. In contrast, no evidence of graft fractures, pseudoarthrosis or foreign body reaction was observed in the treatment group. These results reveal that mPCL–TCP scaffolds could act as bone graft substitutes by providing a suitable environment for bone regeneration in a dynamic load bearing setting such as in a porcine model of interbody spine fusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the use of the FAB-MAP appearance-only SLAM algorithm as a method for performing visual data association for RatSLAM, a semi-metric full SLAM system. While both systems have shown the ability to map large (60-70km) outdoor locations of approximately the same scale, for either larger areas or across longer time periods both algorithms encounter difficulties with false positive matches. By combining these algorithms using a mapping between appearance and pose space, both false positives and false negatives generated by FAB-MAP are significantly reduced during outdoor mapping using a forward-facing camera. The hybrid FAB-MAP-RatSLAM system developed demonstrates the potential for successful SLAM over large periods of time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe research into the identification of anomalous events and event patterns as manifested in computer system logs. Prototype software has been developed with a capability that identifies anomalous events based on usage patterns or user profiles, and alerts administrators when such events are identified. To reduce the number of false positive alerts we have investigated the use of different user profile training techniques and introduce the use of abstractions to group together applications which are related. Our results suggest that the number of false alerts that are generated is significantly reduced when a growing time window is used for user profile training and when abstraction into groups of applications is used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Data flow analysis techniques can be used to help assess threats to data confidentiality and integrity in security critical program code. However, a fundamental weakness of static analysis techniques is that they overestimate the ways in which data may propagate at run time. Discounting large numbers of these false-positive data flow paths wastes an information security evaluator's time and effort. Here we show how to automatically eliminate some false-positive data flow paths by precisely modelling how classified data is blocked by certain expressions in embedded C code. We present a library of detailed data flow models of individual expression elements and an algorithm for introducing these components into conventional data flow graphs. The resulting models can be used to accurately trace byte-level or even bit-level data flow through expressions that are normally treated as atomic. This allows us to identify expressions that safely downgrade their classified inputs and thereby eliminate false-positive data flow paths from the security evaluation process. To validate the approach we have implemented and tested it in an existing data flow analysis toolkit.