245 resultados para blood sampling

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Anaemia is common in critically ill patients, and has a significant negative impact on patients' recovery. Blood conservation strategies have been developed to reduce the incidence of iatrogenic anaemic caused by sampling for diagnostic testing. Objectives Describe practice and local guidelines in adult, paediatric and neonatal Australian intensive care units (ICUs) regarding blood sampling and conservation strategies. Methods Cross-sectional descriptive study, conducted July 2013 over one week in single adult, paediatric and neonatal ICUs in Brisbane. Data were collected on diagnostic blood samples obtained during the study period, including demographic and acuity data of patients. Institutional blood conservation practice and guidelines were compared against seven evidence-based recommendations. Results A total of 940 blood sampling episodes from 96 patients were examined across three sites. Arterial blood gas was the predominant reason for blood sampling in each unit, accounting for 82% of adult, 80% of paediatric and 47% of neonatal samples taken (p <. 0.001). Adult patients had significantly more median [IQR] samples per day in comparison to paediatrics and neonates (adults 5.0 [2.4]; paediatrics 2.3 [2.9]; neonatal 0.7 [2.7]), which significantly increased median [IQR] blood sampling costs per day (adults AUD$101.11 [54.71]; paediatrics AUD$41.55 [56.74]; neonatal AUD$8.13 [14.95]; p <. 0.001). The total volume of samples per day (median [IQR]) was also highest in adults (adults 22.3. mL [16.8]; paediatrics 5.0. mL [1.0]; neonates 0.16. mL [0.4]). There was little information about blood conservation strategies in the local clinical practice guidelines, with the adult and neonatal sites including none of the seven recommendations. Conclusions There was significant variation in blood sampling practice and conservation strategies between critical care settings. This has implications not only for anaemia but also infection control and healthcare costs.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Optimal design methods have been proposed to determine the best sampling times when sparse blood sampling is required in clinical pharmacokinetic studies. However, the optimal blood sampling time points may not be feasible in clinical practice. Sampling windows, a time interval for blood sample collection, have been proposed to provide flexibility in blood sampling times while preserving efficient parameter estimation. Because of the complexity of the population pharmacokinetic models, which are generally nonlinear mixed effects models, there is no analytical solution available to determine sampling windows. We propose a method for determination of sampling windows based on MCMC sampling techniques. The proposed method attains a stationary distribution rapidly and provides time-sensitive windows around the optimal design points. The proposed method is applicable to determine sampling windows for any nonlinear mixed effects model although our work focuses on an application to population pharmacokinetic models.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Malaria rapid diagnostic tests (RDTs) are increasingly used by remote health personnel with minimal training in laboratory techniques. RDTs must, therefore, be as simple, safe and reliable as possible. Transfer of blood from the patient to the RDT is critical to safety and accuracy, and poses a significant challenge to many users. Blood transfer devices were evaluated for accuracy and precision of volume transferred, safety and ease of use, to identify the most appropriate devices for use with RDTs in routine clinical care. Methods: Five devices, a loop, straw-pipette, calibrated pipette, glass capillary tube, and a new inverted cup device, were evaluated in Nigeria, the Philippines and Uganda. The 227 participating health workers used each device to transfer blood from a simulated finger-prick site to filter paper. For each transfer, the number of attempts required to collect and deposit blood and any spilling of blood during transfer were recorded. Perceptions of ease of use and safety of each device were recorded for each participant. Blood volume transferred was calculated from the area of blood spots deposited on filter paper. Results: The overall mean volumes transferred by devices differed significantly from the target volume of 5 microliters (p < 0.001). The inverted cup (4.6 microliters) most closely approximated the target volume. The glass capillary was excluded from volume analysis as the estimation method used is not compatible with this device. The calibrated pipette accounted for the largest proportion of blood exposures (23/225, 10%); exposures ranged from 2% to 6% for the other four devices. The inverted cup was considered easiest to use in blood collection (206/ 226, 91%); the straw-pipette and calibrated pipette were rated lowest (143/225 [64%] and 135/225 [60%] respectively). Overall, the inverted cup was the most preferred device (72%, 163/227), followed by the loop (61%, 138/227). Conclusions: The performance of blood transfer devices varied in this evaluation of accuracy, blood safety, ease of use, and user preference. The inverted cup design achieved the highest overall performance, while the loop also performed well. These findings have relevance for any point-of-care diagnostics that require blood sampling.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Interest in chromosome 18 in essential hypertension comes from comparative mapping of rat blood pressure quantitative trait loci (QTL), familial orthostatic hypotensive syndrome studies, and essential hypertension pedigree linkage analyses indicating that a locus or loci on human chromosome 18 may play a role in hypertension development. To further investigate involvement of chromosome 18 in human essential hypertension, the present study utilized a linkage scan approach to genotype twelve microsatellite markers spanning human chromosome 18 in 177 Australian Caucasian hypertensive (HT) sibling pairs. Linkage analysis showed significant excess allele sharing of the D18S61 marker when analyzed with SPLINK (P=0.00012), ANALYZE (Sibpair) (P=0.0081), and also with MAPMAKER SIBS (P=0.0001). Similarly, the D18S59 marker also showed evidence for excess allele sharing when analyzed with SPLINK (P=0.016), ANALYZE (Sibpair) (P=0.0095), and with MAPMAKER SIBS (P = 0.014). The adenylate cyclase activating polypeptide 1 gene (ADCYAP1) is involved in vasodilation and has been co-localized to the D18S59 marker. Results testing a microsatellite marker in the 3′ untranslated region of ADCYAP1 in age and gender matched HT and normotensive (NT) individuals showed possible association with hypertension (P = 0.038; Monte Carlo P = 0.02), but not with obesity. The present study shows a chromosome 18 role in essential hypertension and indicates that the genomic region near the ADCYAP1 gene or perhaps the gene itself may be implicated. Further investigation is required to conclusively determine the extent to which ADCYAP1 polymorphisms are involved in essential hypertension. © 2003 Wiley-Liss, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Early detection, clinical management and disease recurrence monitoring are critical areas in cancer treatment in which specific biomarker panels are likely to be very important in each of these key areas. We have previously demonstrated that levels of alpha-2-heremans-schmid-glycoprotein (AHSG), complement component C3 (C3), clusterin (CLI), haptoglobin (HP) and serum amyloid A (SAA) are significantly altered in serum from patients with squamous cell carcinoma of the lung. Here, we report the abundance levels for these proteins in serum samples from patients with advanced breast cancer, colorectal cancer (CRC) and lung cancer compared to healthy controls (age and gender matched) using commercially available enzyme-linked immunosorbent assay kits. Logistic regression (LR) models were fitted to the resulting data, and the classification ability of the proteins was evaluated using receiver-operating characteristic curve and leave-one-out cross-validation (LOOCV). The most accurate individual candidate biomarkers were C3 for breast cancer [area under the curve (AUC) = 0.89, LOOCV = 73%], CLI for CRC (AUC = 0.98, LOOCV = 90%), HP for small cell lung carcinoma (AUC = 0.97, LOOCV = 88%), C3 for lung adenocarcinoma (AUC = 0.94, LOOCV = 89%) and HP for squamous cell carcinoma of the lung (AUC = 0.94, LOOCV = 87%). The best dual combination of biomarkers using LR analysis were found to be AHSG + C3 (AUC = 0.91, LOOCV = 83%) for breast cancer, CLI + HP (AUC = 0.98, LOOCV = 92%) for CRC, C3 + SAA (AUC = 0.97, LOOCV = 91%) for small cell lung carcinoma and HP + SAA for both adenocarcinoma (AUC = 0.98, LOOCV = 96%) and squamous cell carcinoma of the lung (AUC = 0.98, LOOCV = 84%). The high AUC values reported here indicated that these candidate biomarkers have the potential to discriminate accurately between control and cancer groups both individually and in combination with other proteins. Copyright © 2011 UICC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fifty-nine persons with industrial handling of low levels of acrylonitrile (AN) were studied. As part of a medical surveillance programme an extended haemoglobin adduct monitoring [N-(cyanoethyl)valine, CEV; N- (methyl)valine, MV; N-(hydroxyethyl)valine, HEV] was performed. Moreover, the genetic states of the polymorphic glutathione transferases GSTM1 and GSTT1 were assayed by polymerase chain reaction (PCR). Repetitive analyses of CEV and MV in subsequent years resulted in comparable values (means, 59.8 and 70.3 μg CEV/1 blood; 6.7 and 6.7 μg MV/1 blood). Hence, the industrial AN exposures were well below current official standards. Monitoring the haemoglobin adduct CEV appears as a suitable means of biomonitoring and medical surveillance under such exposure conditions. There was also no apparent correlation between the CEV and HEV or CEV and MV adduct levels. The MV and HEV values observed represented background levels, which apparently are not related to any occupational chemical exposure. There was no consistent effect of the genetic GSTM1 or GSTT1 state on CEV adduct levels induced by acrylonitrile exposure. Therefore, neither GSTM1 nor GSTT1 appears as a major AN metabolizing isoenzyme in humans. The low and physiological background levels of MV were also not influenced by the genetic GSTM1 state, but the MV adduct levels tended to be higher in GSTT1- individuals compared to GSTT1 + persons. With respect to the background levels of HEV adducts observed, there was no major influence of the GSTM1 state, but GST- individuals displayed adduct levels that were about 1/3 higher than those of GSTT1+ individuals. The coincidence with known differences in rates of background sister chromatid exchange between GSTT1- and GSTT1 + persons suggests that the lower ethylene oxide (EO) detoxification rate in GSTT1- persons, indicated by elevated blood protein hydroxyethyl adduct levels, leads to an increased genotoxic effect of the physiological EO background.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The high priority of monitoring workers exposed to nitrobenzene is a consequence of clear findings of experimental carcinogenicity of nitrobenzene and the associated evaluations by the International Agency for Research on Cancer. Eighty male employees of a nitrobenzene reduction plant, with potential skin contact with nitrobenzene and aniline, participated in a current medical surveillance programme. Blood samples were routinely taken and analysed for aniline, 4-aminodiphenyl (4-ADP) and benzidine adducts of haemoglobin (Hb) and human serum albumin (HSA). Also, levels of methaemoglobin (Met-Hb) and of carbon monoxide haemoglobin (CO-Hb) were monitored. Effects of smoking were straightforward. Using the rank sum test of Wilcoxon, we found that very clear-cut and statistically significant smoking effects (about 3-fold increases) were apparent on CO-Hb (P = 0.00085) and on the Hb adduct of 4-ADP (P = 0.0006). The mean aniline-Hb adduct level in smokers was 1.5 times higher than in non-smokers; the significance (P = 0.05375) was close to the 5% level. The strongest correlation was evident between the Hb and HSA adducts of aniline (rs = 0.846). Less pronounced correlations (but with P values < 0.02) appeared between aniline-Hb and 4-ADP-Hb adducts (rs = 0.388), between 4-ADP and 4-ADP-HSA adducts (rs = 0.373), and between 4-ADP-Hb and aniline-HSA adducts (rs = 0.275). In view of the proposal for additional use of the aniline-HSA adduct for biological monitoring, particularly in cases of acute overexposures or poisonings, the strong correlation of the Hb and HSA conjugates is noteworthy; the ratio aniline-HSA:aniline-Hb was 1:42 for the entire cohort.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Over the past 10 years, the use of saliva as a diagnostic fluid has gained attention and has become a translational research success story. Some of the current nanotechnologies have been demonstrated to have the analytical sensitivity required for the use of saliva as a diagnostic medium to detect and predict disease progression. However, these technologies have not yet been integrated into current clinical practice and work flow. CONTENT: As a diagnostic fluid, saliva offers advantages over serum because it can be collected noninvasively by individuals with modest training, and it offers a cost-effective approach for the screening of large populations. Gland-specific saliva can also be used for diagnosis of pathology specific to one of the major salivary glands. There is minimal risk of contracting infections during saliva collection, and saliva can be used in clinically challenging situations, such as obtaining samples from children or handicapped or anxious patients, in whom blood sampling could be a difficult act to perform. In this review we highlight the production of and secretion of saliva, the salivary proteome, transportation of biomolecules from blood capillaries to salivary glands, and the diagnostic potential of saliva for use in detection of cardiovascular disease and oral and breast cancers. We also highlight the barriers to application of saliva testing and its advancement in clinical settings. SUMMARY: Saliva has the potential to become a first-line diagnostic sample of choice owing to the advancements in detection technologies coupled with combinations of biomolecules with clinical relevance. (C) 2011 American Association for Clinical Chemistry

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Over the past 10 years, the use of saliva as a diagnostic fluid has gained attention and has become a translational research success story. Some of the current nanotechnologies have been demonstrated to have the analytical sensitivity required for the use of saliva as a diagnostic medium to detect and predict disease progression. However, these technologies have not yet been integrated into current clinical practice and work flow. As a diagnostic fluid, saliva offers advantages over serum because it can be collected noninvasively by individuals with modest training, and it offers a cost-effective approach for the screening of large populations. Gland-specific saliva can also be used for diagnosis of pathology specific to one of the major salivary glands. There is minimal risk of contracting infections during saliva collection, and saliva can be used in clinically challenging situations, such as obtaining samples from children or handicapped or anxious patients, in whom blood sampling could be a difficult act to perform. In this review we highlight the production of and secretion of saliva, the salivary proteome, transportation of biomolecules from blood capillaries to salivary glands, and the diagnostic potential of saliva for use in detection of cardiovascular disease and oral and breast cancers. We also highlight the barriers to application of saliva testing and its advancement in clinical settings. Saliva has the potential to become a first-line diagnostic sample of choice owing to the advancements in detection technologies coupled with combinations of biomolecules with clinical relevance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Giant Cell Arteritis (GCA) is the most common vasculitis affecting the elderly. Archived formalin-fixed paraffin-embedded (FFPE) temporal artery biopsy (TAB) specimens potentially represent a valuable resource for large-scale genetic analysis of this disease. FFPE TAB samples were obtained from 12 patients with GCA. Extracted TAB DNA was assessed by real time PCR before restoration using the Illumina HD FFPE Restore Kit. Paired FFPE-blood samples were genotyped on the Illumina OmniExpress FFPE microarray. The FFPE samples that passed stringent quality control measures had a mean genotyping success of >97%. When compared with their matching peripheral blood DNA, the mean discordant heterozygote and homozygote single nucleotide polymorphisms calls were 0.0028 and 0.0003, respectively, which is within the accepted tolerance of reproducibility. This work demonstrates that it is possible to successfully obtain high-quality microarray-based genotypes FFPE TAB samples and that this data is similar to that obtained from peripheral blood.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Vitamin D is synthesised in the skin through the action of UVB radiation (sunlight), and 25-hydroxy vitamin D (25OHD) measured in serum as a marker of vitamin D status. Several studies, mostly conducted in high latitudes, have shown an association between type 1 diabetes mellitus (T1DM) and low serum 25OHD. We conducted a case-control study to determine whether, in a sub-tropical environment with abundant sunlight (latitude 27.5°S), children with T1DM have lower serum vitamin D than children without diabetes. Fifty-six children with T1DM (14 newly diagnosed) and 46 unrelated control children participated in the study. Serum 25OHD, 1,25-dihydroxy vitamin D (1,25(OH)2D) and selected biochemical indices were measured. Vitamin D receptor (VDR) polymorphisms Taq1, Fok1, and Apa1 were genotyped. Fitzpatrick skin classification, self-reported daily hours of outdoor exposure, and mean UV index over the 35d prior to blood collection were recorded. Serum 25OHD was lower in children with T1DM (n=56) than in controls (n=46) [mean (95%CI)=78.7 (71.8-85.6) nmol/L vs. 91.4 (83.5-98.7) nmol/L, p=0.02]. T1DM children had lower self-reported outdoor exposure and mean UV exposure, but no significant difference in distribution of VDR polymorphisms. 25OHD remained lower in children with T1DM after covariate adjustment. Children newly diagnosed with T1DM had lower 1,25(OH)2D [median (IQR)=89 (68-122) pmol/L] than controls [121 (108-159) pmol/L, p=0.03], or children with established diabetes [137 (113-153) pmol/L, p=0.01]. Children with T1DM have lower 25OHD than controls, even in an environment of abundant sunlight. Whether low vitamin D is a risk factor or consequence of T1DM is unknown. © 2012 John Wiley & Sons A/S.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background People admitted to intensive care units and those with chronic health care problems often require long-term vascular access. Central venous access devices (CVADs) are used for administering intravenous medications and blood sampling. CVADs are covered with a dressing and secured with an adhesive or adhesive tape to protect them from infection and reduce movement. Dressings are changed when they become soiled with blood or start to come away from the skin. Repeated removal and application of dressings can cause damage to the skin. The skin is an important barrier that protects the body against infection. Less frequent dressing changes may reduce skin damage, but it is unclear whether this practice affects the frequency of catheter-related infections. Objectives To assess the effect of the frequency of CVAD dressing changes on the incidence of catheter-related infections and other outcomes including pain and skin damage. Search methods In June 2015 we searched: The Cochrane Wounds Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE and EBSCO CINAHL. We also searched clinical trials registries for registered trials. There were no restrictions with respect to language, date of publication or study setting. Selection criteria All randomised controlled trials (RCTs) evaluating the effect of the frequency of CVAD dressing changes on the incidence of catheter-related infections on all patients in any healthcare setting. Data collection and analysis We used standard Cochrane review methodology. Two review authors independently assessed studies for inclusion, performed risk of bias assessment and data extraction. We undertook meta-analysis where appropriate or otherwise synthesised data descriptively when heterogeneous. Main results We included five RCTs (2277 participants) that compared different frequencies of CVAD dressing changes. The studies were all conducted in Europe and published between 1995 and 2009. Participants were recruited from the intensive care and cancer care departments of one children's and four adult hospitals. The studies used a variety of transparent dressings and compared a longer interval between dressing changes (5 to15 days; intervention) with a shorter interval between changes (2 to 5 days; control). In each study participants were followed up until the CVAD was removed or until discharge from ICU or hospital. - Confirmed catheter-related bloodstream infection (CRBSI) One trial randomised 995 people receiving central venous catheters to a longer or shorter interval between dressing changes and measured CRBSI. It is unclear whether there is a difference in the risk of CRBSI between people having long or short intervals between dressing changes (RR 1.42, 95% confidence interval (CI) 0.40 to 4.98) (low quality evidence). - Suspected catheter-related bloodstream infection Two trials randomised a total of 151 participants to longer or shorter dressing intervals and measured suspected CRBSI. It is unclear whether there is a difference in the risk of suspected CRBSI between people having long or short intervals between dressing changes (RR 0.70, 95% CI 0.23 to 2.10) (low quality evidence). - All cause mortality Three trials randomised a total of 896 participants to longer or shorter dressing intervals and measured all cause mortality. It is unclear whether there is a difference in the risk of death from any cause between people having long or short intervals between dressing changes (RR 1.06, 95% CI 0.90 to 1.25) (low quality evidence). - Catheter-site infection Two trials randomised a total of 371 participants to longer or shorter dressing intervals and measured catheter-site infection. It is unclear whether there is a difference in risk of catheter-site infection between people having long or short intervals between dressing changes (RR 1.07, 95% CI 0.71 to 1.63) (low quality evidence). - Skin damage One small trial (112 children) and three trials (1475 adults) measured skin damage. There was very low quality evidence for the effect of long intervals between dressing changes on skin damage compared with short intervals (children: RR of scoring ≥ 2 on the skin damage scale 0.33, 95% CI 0.16 to 0.68; data for adults not pooled). - Pain Two studies involving 193 participants measured pain. It is unclear if there is a difference between long and short interval dressing changes on pain during dressing removal (RR 0.80, 95% CI 0.46 to 1.38) (low quality evidence). Authors' conclusions The best available evidence is currently inconclusive regarding whether longer intervals between CVAD dressing changes are associated with more or less catheter-related infection, mortality or pain than shorter intervals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Ongoing shortages of blood products may be addressed through additional donations. However, donation frequency rates are typically lower than medically possible. This preliminary study aims to determine voluntary nonremunerated whole blood (WB) and plasmapheresis donors' willingness, and subsequent facilitators and barriers, to make additional donations of a different type. STUDY DESIGN AND METHODS Forty individual telephone interviews were conducted posing two additional donation pattern scenarios: first, making a single and, second, making multiple plasmapheresis donations between WB donations. Stratified purposive sampling was conducted for four samples varying in donation experience: no-plasma, new-to-both-WB-and-plasma, new-to-plasma, and plasma donors. Interviews were analyzed yielding excellent (κ values > 0.81) inter-rater reliability. RESULTS Facilitators were more endorsed than barriers for a single but not multiple plasmapheresis donation. More new-to-both donors (n = 5) were willing to make multiple plasma donations between WB donations than others (n = 1 each) and identified fewer barriers (n = 3) than those more experienced in donation (n = 8 no plasma, n = 10 new to both, n = 11 plasma). Donors in the plasma sample were concerned about the subsequent reduced time between plasma donations by adding WB donations (n = 3). The no-plasma and new-to-plasma donors were concerned about the time commitment required (n = 3). CONCLUSION Current donors are willing to add different product donations but donation history influences their willingness to change. Early introduction of multiple donation types, variation in inventory levels, and addressing barriers will provide blood collection agencies with a novel and cost-effective inventory management strategy.