75 resultados para after Bray and Evans (1961)

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intense exercise stimulates the systemic release of a variety of factors that alter neutrophil surface receptor expression and functional activity. These alterations may influence resistance to infection after intense exercise. The aim of this study was to examine the influence of exercise intensity on neutrophil receptor expression, degranulation (measured by plasma and intracellular myeloperoxidase concentrations), and respiratory burst activity. Ten well-trained male runners ran on a treadmill for 60 min at 60% [moderate-intensity exercise (MI)] and 85% maximal oxygen consumption [high-intensity exercise (HI)]. Blood was drawn immediately before and after exercise and at 1 h postexercise. Immediately after HI, the expression of the neutrophil receptor CD16 was significantly below preexercise values (P < 0.01), whereas MI significantly reduced CD35 expression below preexercise values (P < 0.05). One hour after exercise at both intensities, there was a significant decline in CD11b expression (P < 0.05) and a further decrease in CD16 expression compared with preexercise values (P < 0.01). CD16 expression was lower 1 h after HI than 1 h after MI (P < 0.01). Immediately after HI, intracellular myeloperoxidase concentration was less than preexercise values (P < 0.01), whereas plasma myeloperoxidase concentration was greater (P < 0.01), indicating that HI stimulated neutrophil degranulation. Plasma myeloperoxidase concentration was higher immediately after HI than after MI (P < 0.01). Neutrophil respiratory burst activity increased after HI (P < 0.01). In summary, both MI and HI reduced neutrophil surface receptor expression. Although CD16 expression was reduced to a greater extent after HI, this reduction did not impair neutrophil degranulation and respiratory burst activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose The aim of this study was to determine the early time course of exercise-induced signaling after divergent contractile activity associated with resistance and endurance exercise. Methods Sixteen male subjects were randomly assigned to either a cycling (CYC; n = 8, 60 min, 70% V?O2peak) or resistance (REX; n = 8, 8×5 leg extension, 80% one-repetition maximum, 3-min recovery) exercise group. Serial muscle biopsies were obtained from vastus lateralis at rest before, immediately after, and after 15, 30, and 60 min of passive recovery to determine early signaling responses after exercise. Results There were comparable increases from rest in AktThr308/Ser473 and mTORSer2448 phosphorylation during the postexercise time course that peaked 30-60 min after both CYC and REX (P<0.05). There were also similar patterns in p70S6K Thr389 and 4E-BP1Thr37/46 phosphorylation, but a greater magnitude of effect was observed for REX and CYC, respectively (P<0.05). However, AMPKThr172 phosphorylation was only significantly elevated after CYC (P<0.05), and we observed divergent responses for glycogen synthaseSer641 and AS160 phosphorylation that were enhanced after CYC but not REX (P<0.05). Conclusions We show a similar time course for Akt-mTOR-S6K phosphorylation during the initial 60-min recovery period after divergent contractile stimuli. Conversely, enhanced phosphorylation status of proteins that promote glucose transport and glycogen synthesis only occurred after endurance exercise. Our results indicate that endurance and resistance exercise initiate translational signaling, but high-load, low-repetition contractile activity failed to promote phosphorylation of pathways regulating glucose metabolism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current study sought to explore whether the subcutaneous administration of lymph-targeted dendrimers, conjugated with a model chemotherapeutic (methotrexate, MTX), was able to enhance anticancer activity against lymph node metastases. The lymphatic pharmacokinetics and antitumour activity of PEGylated polylysine dendrimers conjugated to MTX [D-MTX(OH)] via a tumour-labile hexapeptide linker was examined in rats and compared to a similar system where MTX was α-carboxyl O-tert-butylated [D-MTX(OtBu)]. The latter has previously been shown to exhibit longer plasma circulation times. D-MTX(OtBu) was well absorbed from the subcutaneous injection site via the lymph, and 3 to 4%/g of the dose was retained by sentinel lymph nodes. In contrast, D-MTX(OH) showed limited absorption from the subcutaneous injection site, but absorption was almost exclusively via the lymph. The retention of D-MTX(OH) by sentinel lymph nodes was also significantly elevated (approximately 30% dose/g). MTX alone was not absorbed into the lymph. All dendrimers displayed lower lymph node targeting after intravenous administration. Despite significant differences in the lymph node retention of D-MTX(OH) and D-MTX(OtBu) after subcutaneous and intravenous administration, the growth of lymph node metastases was similarly inhibited. In contrast, the administration of MTX alone did not significantly reduce lymph node tumour growth. Subcutaneous administration of drug-conjugated dendrimers therefore provides an opportunity to improve drug deposition in downstream tumour-burdened lymph nodes. In this case, however, increased lymph node biodistribution did not correlate well with antitumour activity, possibly suggesting constrained drug release at the site of action.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alasdair MacIntyre’s After Virtue presented a reinterpretation of Aristotelian virtue ethics that is contrasted with the emotivism of modern moral discourse, and provides a moral scheme that can enable a rediscovery and reimagination of a more coherent morality. Since After Virtue’s publication, this scheme has been applied to a variety of activities and occupations, and has been influential in the development of research in accounting ethics. Through a ‘close’ reading of chapters 14 and 15 of After Virtue this paper considers and applies the key concepts of practices, institutions, internal and external goods, the narrative unity of a human life and tradition, and the virtues associated with these concepts. It contributes, firstly, by providing a more accurate and comprehensive application of MacIntyre’s scheme to accounting than available in the existing literature. Secondly, it identifies areas in which MacIntyre’s scheme supports the existing approach to professional accounting ethics as articulated by the various International Federation of Accountants pronouncements as well as areas in which it provides a critique and challenge to this approach. The application ultimately provides an alternative philosophical perspective through which accounting can be examined and further research into accounting ethics pursued.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

'Untitled (after Steven and John)' takes inspiration from Spielbergian tracking shots and Baldessarian collages to create ghostly apparitions that explore the affective power of the cinematic close up. By appropriating and obfuscating this common filmic convention, the work investigates the intersubjective potential of the moving image.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Diagnosis of epithelial ovarian cancer (EOC) in young women has major implications including those to their reproductive potential. We evaluated depression, anxiety and body image in patients with stage I EOC treated with fertility sparing surgery (FSS) or radical surgery (RS). We also investigated fertility outcomes after FSS.----- Methods: A retrospective study was undertaken in which 62 patients completed questionnaires related to anxiety, depression, body image and fertility outcomes. Additional information on adjuvant therapy after FSS and RS and demographic details were abstracted from medical records. Both bi and multivariate regression models were used to assess the relationship between demographic, clinical and pathological results and scores for anxiety, depression and body image.----- Results: Thirty-nine patients underwent RS and the rest, FSS. The percentage of patients reporting elevated anxiety and depression (subscores ≥ 11) were 27 % and 5% respectively. The median (inter quartile range) score for body image scale (BIS) was 6 (3-15). None of the demographic or clinical factors examined showed significant association with anxiety and BIS with the exception of ‘time since diagnosis’. For depression, post-menopausal status was the only independent predictor. Among those 23 patients treated by FSS, 14 patients tried to conceive (7 successful), resulting in 7 live births, one termination of pregnancy and one miscarriage.----- Conclusion: This study shows that psychological issues are common in women treated for stage I EOC. Reproduction after FSS is feasible and lead to the birth of healthy babies in about half of patients who wished to have another child. Further prospective studies with standardised instruments are required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Little is known about cancer survivors’ experiences with and preferences for exercise programmes offered during rehabilitation (immediately after cancer treatment). This study documented colorectal cancer survivors’ experiences in an exercise rehabilitation programme and their preferences for programme content and delivery. At the completion of 12-weeks of supervised exercise, 10 participants took part in one-on-one semi-structured interviews. Data from these interviews were coded, and themes were identified using qualitative software. Key findings were that most participants experienced improvements in treatment symptoms, including reduced fatigue and increased energy and confidence to do activities of daily living. They also reported that interactions with the exercise trainer and a flexible programme delivery were important aspects of the intervention. Most participants reported that they preferred having a choice of exercise, starting to exercise within a month after completing treatment, having supervision and maintaining a one-on-one format. Frustrations included scheduling conflicts and a lack of a transition out of the programme. The findings indicate that colorectal cancers experience benefits from exercise offered immediately after treatment and prefer individual attention from exercise staff. They further indicate directions for the implementation of future exercise programmes with this population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background: The importance of quality-of-life (QoL) research has been recognised over the past two decades in patients with head and neck (H&N) cancer. The aims of this systematic review are to evaluate the QoL status of H&N cancer survivors one year after treatment and to identify the determinants affecting their QoL. Methods: Pubmed, Medline, Scopus, Sciencedirect and CINAHL (2000–2011) were searched for relevant studies, and two of the present authors assessed their methodological quality. The characteristics and main findings of the studies were extracted and reported. Results: Thirty-seven studies met the inclusion criteria, and the methodological quality of the majority was moderate to high. While patients of the group in question recover their global QoL by 12 months after treatment, a number of outstanding issues persist – deterioration in physical functioning, fatigue, xerostomia and sticky saliva. Age, cancer site, stage of disease, social support, smoking, feeding tube placement and alcohol consumption are the significant determinants of QoL at 12 months, while gender has little or no influence. Conclusions: Regular assessments should be carried out to monitor physical functioning,degree of fatigue, xerostomia and sticky saliva. Further research is required to develop appropriate and effective interventions to deal with these issues, and thus to promote the patients’ QoL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to examine whether older people are prepared to engage in appropriate falls prevention strategies after discharge from hospital. Design and Methods We used a semi-structured interview to survey older patients about to be discharged from hospital and examined their knowledge regarding falls prevention strategies to utilize in the post-discharge period. The study was part of a prospective cohort study, nested within a larger, randomized controlled trial. Participants (n = 333) were asked to suggest strategies to reduce their falls risk at home after discharge, and their responses were compared with current reported research evidence for falls prevention interventions.  Results Participants’ strategies (n = 629) were classified into 7 categories: behavioral, support while mobilizing, approach to movement, physical environment, visual, medical, and activities or exercise. Although exercise has been identified as an effective falls risk reduction strategy, only 2.9% of participants suggested engaging in exercises. Falls prevention was most often conceptualized by participants as requiring 1 (35.4%) or 2 (40.8%) strategies for avoiding an accidental event, rather than engaging in sustained multiple risk reduction behaviors.  Implications Results demonstrate that older patients have low levels of knowledge about appropriate falls prevention strategies that could be used after discharge in spite of their increased falls risk during this period. Findings suggest that health care workers should design and deliver falls prevention education programs specifically targeted to older people who are to be discharged from hospital.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study examined the effect of carbohydrate supplementation on changes in neutrophil counts, and the plasma concentrations of cortisol and myoglobin after intense exercise. Eight well-trained male runners ran on a treadmill for 1 h at 85% maximal oxygen uptake on two separate occasions. In a double-blind cross-over design, subjects consumed either 750 ml of a 10% carbohydrate (CHO) drink or a placebo drink on each occasion. The order of the trials was counter-balanced. Blood was drawn immediately before and after exercise, and 1 h after exercise. Immediately after exercise, neutrophil counts (CHO, 49%; placebo, 65%; P<0.05), plasma concentrations of glucose (CHO, 43%; P<0.05), lactate (CHO, 130%; placebo, 130%; P<0.01), cortisol (CHO, 100%; placebo, 161%; P<0.01), myoglobin (CHO, 194%; placebo, 342%; P<0.01) all increased significantly. One hour post-exercise, plasma myoglobin concentration (CHO, 331%; placebo, 482%; P<0.01) and neutrophil count (CHO, 151%; placebo, 230% P<0.01) both increased further above baseline. CHO significantly attenuated plasma myoglobin concentration and the neutrophil count after exercise (P<0.01), but did not affect plasma cortisol concentration. The effects of CHO on plasma myoglobin concentration may be due to alterations in cytokine synthesis, insulin responses or myoglobin clearance rates from the bloodstream during exercise. Plasma cortisol responses to CHO during exercise may depend on the intensity of exercise, or the amount of CHO consumed. Lastly, cortisol appears to play a minor role in the mobilisation of neutrophils after intense exercise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The texture of agricultural crops changes during harvesting, post harvesting and processing stages due to different loading processes. There are different source of loading that deform agricultural crop tissues and these include impact, compression, and tension. Scanning Electron Microscope (SEM) method is a common way of analysing cellular changes of materials before and after these loading operations. This paper examines the structural changes of pumpkin peel and flesh tissues under mechanical loading. Compression and indentation tests were performed on peel and flesh samples. Samples structure were then fixed and dehydrated in order to capture the cellular changes under SEM. The results were compared with the images of normal peel and flesh tissues. The findings suggest that normal flesh tissue had bigger size cells, while the cellular arrangement of peel was smaller. Structural damage was clearly observed in tissue structure after compression and indentation. However, the damages that resulted from the flat end indenter was much more severe than that from the spherical end indenter and compression test. An integrated deformed tissue layer was observed in compressed tissue, while the indentation tests shaped a deformed area under the indenter and left the rest of the tissue unharmed. There was an obvious broken layer of cells on the walls of the hole after the flat end indentations, whereas the spherical indenter created a squashed layer all around the hole. Furthermore, the influence of loading was lower on peel samples in comparison with the flesh samples. The experiments have shown that the rate of damage on tissue under constant rate of loading is highly dependent on the shape of equipment. This fact and observed structural changes after loading underline the significance of deigning post harvesting equipments to reduce the rate of damage on agricultural crop tissues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Although advances in treatment modalities have improved the survival of head and neck (H&N) cancer patients over recent years, survivors’ quality of life (QoL) could be impaired for a number of reasons. The investigation of QoL determinants can inform the design of supportive interventions for this population. Objectives: To examine the QoL of H&N cancer survivors at 1 year after treatment and to identify potential determinants affecting their QoL. Methods: A systematic search of literature was done in December 2011 in five databases: Pubmed, Medline, Scopus, Sciencedirect and CINAHL, using combined search terms ‘head and neck cancer’, ‘quality of life’, ‘health-related quality of life’ and ‘systematic review’. The methodological qualities of selected studies were assessed by two reviewers using predefined criteria. The study characteristics and results were abstracted and summarized. Results: Thirty-seven studies met all inclusion criteria with methodological quality from moderate to high. The global QoL of H&N cancer survivors returned to baseline at 1 year after treatment. Significant improvement showed in emotional functioning while physical functioning, xerostomia, sticky/insufficient saliva, and fatigue were consistently worse at 12 months compared with baseline. Age, cancer sites and stages, social support, smoking, presence of feeding tube are significant QoL determinants at 12 months. Conclusions: Although the global QoL of H&N cancer survivors recover by 12 months after treatment, problems with physical functioning, fatigue, xerostomia and sticky saliva persist. Regular assessment should be carried out to monitor these problems. Further research is required to develop appropriate and effective interventions for this population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The use of amorphous-silicon electronic portal imaging devices (a-Si EPIDs) for dosimetry is complicated by the effects of scattered radiation. In photon radiotherapy, primary signal at the detector can be accompanied by photons scattered from linear accelerator components, detector materials, intervening air, treatment room surfaces (floor, walls, etc) and from the patient/phantom being irradiated. Consequently, EPID measurements which presume to take scatter into account are highly sensitive to the identification of these contributions. One example of this susceptibility is the process of calibrating an EPID for use as a gauge of (radiological) thickness, where specific allowance must be made for the effect of phantom-scatter on the intensity of radiation measured through different thicknesses of phantom. This is usually done via a theoretical calculation which assumes that phantom scatter is linearly related to thickness and field-size. We have, however, undertaken a more detailed study of the scattering effects of fields of different dimensions when applied to phantoms of various thicknesses in order to derive scattered-primary ratios (SPRs) directly from simulation results. This allows us to make a more-accurate calibration of the EPID, and to qualify the appositeness of the theoretical SPR calculations. Methods: This study uses a full MC model of the entire linac-phantom-detector system simulated using EGSnrc/BEAMnrc codes. The Elekta linac and EPID are modelled according to specifications from the manufacturer and the intervening phantoms are modelled as rectilinear blocks of water or plastic, with their densities set to a range of physically realistic and unrealistic values. Transmissions through these various phantoms are calculated using the dose detected in the model EPID and used in an evaluation of the field-size-dependence of SPR, in different media, applying a method suggested for experimental systems by Swindell and Evans [1]. These results are compared firstly with SPRs calculated using the theoretical, linear relationship between SPR and irradiated volume, and secondly with SPRs evaluated from our own experimental data. An alternate evaluation of the SPR in each simulated system is also made by modifying the BEAMnrc user code READPHSP, to identify and count those particles in a given plane of the system that have undergone a scattering event. In addition to these simulations, which are designed to closely replicate the experimental setup, we also used MC models to examine the effects of varying the setup in experimentally challenging ways (changing the size of the air gap between the phantom and the EPID, changing the longitudinal position of the EPID itself). Experimental measurements used in this study were made using an Elekta Precise linear accelerator, operating at 6MV, with an Elekta iView GT a-Si EPID. Results and Discussion: 1. Comparison with theory: With the Elekta iView EPID fixed at 160 cm from the photon source, the phantoms, when positioned isocentrically, are located 41 to 55 cm from the surface of the panel. At this geometry, a close but imperfect agreement (differing by up to 5%) can be identified between the results of the simulations and the theoretical calculations. However, this agreement can be totally disrupted by shifting the phantom out of the isocentric position. Evidently, the allowance made for source-phantom-detector geometry by the theoretical expression for SPR is inadequate to describe the effect that phantom proximity can have on measurements made using an (infamously low-energy sensitive) a-Si EPID. 2. Comparison with experiment: For various square field sizes and across the range of phantom thicknesses, there is good agreement between simulation data and experimental measurements of the transmissions and the derived values of the primary intensities. However, the values of SPR obtained through these simulations and measurements seem to be much more sensitive to slight differences between the simulated and real systems, leading to difficulties in producing a simulated system which adequately replicates the experimental data. (For instance, small changes to simulated phantom density make large differences to resulting SPR.) 3. Comparison with direct calculation: By developing a method for directly counting the number scattered particles reaching the detector after passing through the various isocentric phantom thicknesses, we show that the experimental method discussed above is providing a good measure of the actual degree of scattering produced by the phantom. This calculation also permits the analysis of the scattering sources/sinks within the linac and EPID, as well as the phantom and intervening air. Conclusions: This work challenges the assumption that scatter to and within an EPID can be accounted for using a simple, linear model. Simulations discussed here are intended to contribute to a fuller understanding of the contribution of scattered radiation to the EPID images that are used in dosimetry calculations. Acknowledgements: This work is funded by the NHMRC, through a project grant, and supported by the Queensland University of Technology (QUT) and the Royal Brisbane and Women's Hospital, Brisbane, Australia. The authors are also grateful to Elekta for the provision of manufacturing specifications which permitted the detailed simulation of their linear accelerators and amorphous-silicon electronic portal imaging devices. Computational resources and services used in this work were provided by the HPC and Research Support Group, QUT, Brisbane, Australia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of nutrient availability on the acute molecular responses following repeated sprint exercise is unknown. The aim of this study was to determine skeletal muscle cellular and protein synthetic responses following repeated sprint exercise with nutrient provision. Eight healthy young male subjects undertook two sprint cycling sessions (10 × 6 s, 0.75 N m torque kg -1, 54 s recovery) with either pre-exercise nutrient (24 g whey, 4.8 g leucine, 50 g maltodextrin) or non-caloric placebo ingestion. Muscle biopsies were taken from vastus lateralis at rest, and after 15 and 240 min post-exercise recovery to determine muscle cell signalling responses and protein synthesis by primed constant infusion of L-[ring- 13C 6] phenylalanine. Peak and mean power outputs were similar between nutrient and placebo trials. Post-exercise myofibrillar protein synthetic rate was greater with nutrient ingestion compared with placebo ( ? 48%, P<0.05) but the rate of mitochondrial protein synthesis was similar between treatments. The increased myofibrillar protein synthesis following sprints with nutrient ingestion was associated with coordinated increases in Akt-mTOR-S6KrpS6 phosphorylation 15 min post-exercise (?200-600%, P<0.05), while there was no effect on these signalling molecules when exercise was undertaken in the fasted state. For the first time we report a beneficial effect of nutrient provision on anabolic signalling and muscle myofibrillar protein synthesis following repeated sprint exercise. Ingestion of protein/carbohydrate in close proximity to high-intensity sprint exercise provides an environment that increases cell signalling and protein synthesis.