This paper presents the ultrasonic velocity measurement method which investigates the possible effects of high voltage high frequency pulsed power on cortical bone material elasticity. Before applying a pulsed power signal on a live bone, it is essential to determine the safe parameters of pulsed power applied on bone non-destructively. Therefore, the possible changes in cortical bone material elasticity due to a specified pulsed power excitation have been investigated. A controllable positive buck-boost converter with adjustable output voltage and frequency has been used to generate high voltage pulses (500V magnitude at 10 KHz frequency). To determine bone elasticity, an ultrasonic velocity measurement has been conducted on two groups of control (unexposed to pulse power but in the same environmental condition) and cortical bone samples exposed to pulsed power. Young’s modulus of cortical bone samples have been determined and compared before and after applying the pulsed power signal. After applying the high voltage pulses, no significant variation in elastic property of cortical bone specimens was found compared to the control. The result shows that pulsed power with nominated parameters can be applied on cortical bone tissue without any considerable negative effect on elasticity of bone material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We aimed to investigate the naturally occurring horizontal plane movements of a head stabilized in a standard ophthalmic headrest and to analyze their magnitude, velocity, spectral characteristics, and correlation to the cardio pulmonary system. Two custom-made air-coupled highly accurate (±2 μm)ultrasound transducers were used to measure the displacements of the head in different horizontal directions with a sampling frequency of 100 Hz. Synchronously to the head movements, an electrocardiogram (ECG) signal was recorded. Three healthy subjects participated in the study. Frequency analysis of the recorded head movements and their velocities was carried out, and functions of coherence between the two displacements and the ECG signal were calculated. Frequency of respiration and the heartbeat were clearly visible in all recorded head movements. The amplitude of head displacements was typically in the range of ±100 μm. The first harmonic of the heartbeat (in the range of 2–3 Hz), rather than its principal frequency, was found to be the dominant frequency of both head movements and their velocities. Coherence analysis showed high interdependence between the considered signals for frequencies of up to 20 Hz. These findings may contribute to the design of better ophthalmic headrests and should help other studies in the decision making of whether to use a heavy headrest or a bite bar.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: In 1970, Enright observed a distortion of perceived driving speed, induced by monocular application of a neutral density (ND) filter. If a driver looks out of the right side of a vehicle with a filter over the right eye, the driver perceives a reduction of the vehicle’s apparent velocity, while applying a ND filter over the left eye increases the vehicle’s apparent velocity. The purpose of the current study was to provide the first empirical measurements of the Enright phenomenon. Methods: Ten experienced drivers were tested and drove an automatic sedan on a closed road circuit. Filters (0.9 ND) were placed over the left, right or both eyes during a driving run, in addition to a control condition with no filters in place. Subjects were asked to look out of the right side of the car and adjust their driving speed to either 40 km/h or 60 km/h. Results: Without a filter or with both eyes filtered subjects showed good estimation of speed when asked to travel at 60 km/h but travelled a mean of 12 to 14 km/h faster than the requested 40 km/h. Subjects travelled faster than these baselines by a mean of 7 to 9 km/h (p < 0.001) with the filter over their right eye, and 3 to 5 km/h slower with the filter over their left eye (p < 0.05). Conclusions: The Enright phenomenon causes significant and measurable distortions of perceived driving speed under realworld driving conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this letter, the velocity distributions of charge carriers in high-mobility polymer thin-film transistors (TFTs) with a diketopyrrolopyrrole- naphthalene copolymer (PDPP-TNT) semiconductor active layer are reported. The velocity distributions are found to be strongly dependent on measurement temperatures as well as annealing conditions. Considerable inhomogeneity is evident at low measurement temperatures and for low annealing temperatures. Such transient transport measurements can provide additional information about charge carrier transport in TFTs which are unavailable using steady-state transport measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report charge-carrier velocity distributions in high-mobility polymer thin-film transistors (PTFTs) employing a dual-gate configuration. Our time-domain measurements of dual-gate PTFTs indicate higher effective mobility as well as fewer low-velocity carriers than in single-gate operation. Such nonquasi-static (NQS) measurements support and clarify the previously reported results of improved device performance in dual-gate devices by various groups. We believe that this letter demonstrates the utility of NQS measurements in studying charge-carrier transport in dual-gate thin-film transistors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The understanding of the loads generated within the prosthetic leg can aid engineers in the design of components and clinicians in the process of rehabilitation. Traditional methods to assess these loads have relied on inverse dynamics. This indirect method estimates the applied load using video recordings and force-plates located at a distance from the region of interest, such as the base of the residuum. The well-known limitations of this method are related to the accuracy of this recursive model and the experimental conditions required (Frossard et al., 2003). Recent developments in sensors (Frossard et al., 2003) and prosthetic fixation (Brånemark et al., 2000) permit the direct measurement of the loads applied on the residuum of transfemoral amputees. In principle, direct measurement should be an appropriate tool for assessing the accuracy of inverse dynamics. The purpose of this paper is to determine the validity of this assumption. The comparative variable used in this study is the velocity of the relative body center of mass (VCOM(t)). The relativity is used to align the static (w.r.t. position) force plate measurement with the dynamic load cell measurement.