23 resultados para Tintoretto, 1512-1594.
em Queensland University of Technology - ePrints Archive
Resumo:
In vitro cardiovascular device performance evaluation in a mock circulation loop (MCL) is a necessary step prior to in vivo testing.A MCL that accurately represents the physiology of the cardiovascular system accelerates the assessment of the device’s ability to treat pathological conditions. To serve this purpose, a compact MCL measuring 600 ¥ 600 ¥ 600 mm (L ¥ W¥ H) was constructed in conjunction with a computer mathematical simulation.This approach allowed the effective selection of physical loop characteristics, such as pneumatic drive parameters, to create pressure and flow, and pipe dimensions to replicate the resistance, compliance, and fluid inertia of the native cardiovascular system. The resulting five-element MCL reproduced the physiological hemodynamics of a healthy and failing heart by altering ventricle contractility, vascular resistance/compliance, heart rate, and vascular volume. The effects of interpatient anatomical variability, such as septal defects and valvular disease, were also assessed. Cardiovascular hemodynamic pressures (arterial, venous, atrial, ventricular), flows (systemic, bronchial, pulmonary), and volumes (ventricular, stroke) were analyzed in real time. The objective of this study is to describe the developmental stages of the compact MCL and demonstrate its value as a research tool for the accelerated development of cardiovascular devices.
Resumo:
Background: To report the incidence and risk factors for hypotony and estimate the risk of sympathetic ophthalmia following diode laser trans-scleral cyclophotocoagulation (TSCPC). Design: Retrospective study using data from a private tertiary glaucoma clinic and review of the literature. Participants: Seventy eyes of 70 patients with refractory glaucoma who received TSCPC treatment. Methods: Review of the records of consecutive patients who underwent TSCPC by a single ophthalmic surgeon and review of the literature. Main Outcome Measures: Hypotony (including phthisis bulbi), sympathetic ophthalmia. Results: Seven eyes (10%; CI 5-19%) developed hypotony and included 4 eyes that developed phthisis. Higher total energy delivered during TSCPC treatment was associated with an increased risk of hypotony: eyes that developed hypotony received a mean total energy of 192.5 ± 73.2 joules, compared to a mean of 152.9 ± 83.2 joules in hypotony-free cases. The difference in mean energy delivered between the hypotony and non-hypotony group was 38.53 (95% CI: -27.57 to 104.63). The risk of sympathetic ophthalmia estimated from a review of the published literature and current series was one in 1512, or 0.07% (CI 0.03% - 0.17%). Conclusions: Total laser energy is one of several risk factors that act in a sufficient component cause-model to produce hypotony in an individual patient. The small sample size precluded inference for other individual putative risk factors but titrating laser energy may help decrease the occurrence of hypotony. The risk of sympathetic ophthalmia calculated from the literature is likely an overestimate caused by publication bias.
Resumo:
Rotary ventricular assist device (VAD) support of the cardiovascular system is susceptible to suction events due to the limited preload sensitivity of these devices. This may be of particular concern with rotary biventricular support (BiVAD) where the native, flow-balancing Starling response is diminished in both ventricles. The reliability of sensor and sensor-less based control systems which aim to control VAD flow based on preload have limitations and thus an alternative solution is desired. This study introduces a compliant inflow cannula (CIC) which could improve the preload sensitivity of a rotary VAD by passively altering VAD flow depending on preload. To evaluate the design, both the CIC and a standard rigid inflow cannula were inserted into a mock circulation loop to enable biventricular heart failure support using configurations of atrial and ventricular inflow, and arterial outflow cannulation. A range of left (LVAD) and right VAD (RVAD) rotational speeds were tested as well as step changes in systemic/pulmonary vascular resistance to alter relative preloads, with resulting flow rates recorded. Simulated suction events were observed, particularly at higher VAD speeds, during support with the rigid inflow cannula, while the CIC prevented suction events under all circumstances. The compliant section passively restricted its internal diameter as preload was reduced, which increased the VAD circuit resistance and thus reduced VAD flow. Therefore, a compliant inflow cannula could potentially be used as a passive control system to prevent suction events in rotary left, right and biventricular support.
Resumo:
Plug-in electric vehicles will soon be connected to residential distribution networks in high quantities and will add to already overburdened residential feeders. However, as battery technology improves, plug-in electric vehicles will also be able to support networks as small distributed generation units by transferring the energy stored in their battery into the grid. Even though the increase in the plug-in electric vehicle connection is gradual, their connection points and charging/discharging levels are random. Therefore, such single-phase bidirectional power flows can have an adverse effect on the voltage unbalance of a three-phase distribution network. In this article, a voltage unbalance sensitivity analysis based on charging/discharging levels and the connection point of plug-in electric vehicles in a residential low-voltage distribution network is presented. Due to the many uncertainties in plug-in electric vehicle ratings and connection points and the network load, a Monte Carlo-based stochastic analysis is developed to predict voltage unbalance in the network in the presence of plug-in electric vehicles. A failure index is introduced to demonstrate the probability of non-standard voltage unbalance in the network due to plug-in electric vehicles.
Resumo:
Lanthanum oxide (La2O3) nanostructured films are synthesized on a p-type silicon wafer by ablation of La2O3 pellet due to interaction with hot dense argon plasmas in a modified dense plasma focus (DPF) device. The nanostructured films are investigated using scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray diffraction (XRD) spectra. SEM study shows the formation of nano-films having nano-size structures with the average nanostructures size ~25, ~53, and ~45 nm for one, two, and three DPF shots, respectively. The nanostructures sizes and morphology of nano-films are consistent between the AFM and SEM analyses. XRD spectra confirms nano-sized La2O3 with an average grain size ~34, ~51, and ~42 nm for one, two, and three DPF shots, respectively. The electrical properties such as current-voltage and capacitance-voltage (C-V) characteristics of the Al-La2O3-Si metal-oxide- semiconductor (MOS) capacitor structure are measured. The current conduction mechanism of the MOS capacitors is also demonstrated. The C-V characteristics are further used to obtain the electrical parameters such as the dielectric constant, oxide thickness, flat-band capacitance, and flat-band voltage of the MOS capacitors. These measurements demonstrate significantly lower leakage currents without any commonly used annealing or doping, thereby revealing a significant improvement of the MOS nanoelectronic device performance due to the incorporation of the DPF-produced La2O3 nano-films.
Resumo:
The socially responsible investment (SRI) funds performances remain inconclusive. Hence, more studies need to be conducted to determine if SRI funds systematically underperform or outperform conventional funds. This paper has employed dynamic mean-variance model using shortage function approach to evaluate the performance of SRI and Environmentally friendly funds (EF). Unlike the traditional methods, this approach estimates fund performance considering both the return and risk at the same time. The empirical results show that SRI funds outperformed conventional funds in EU and US. In addition, the results of EU are among the top-performing categories. EF do not perform as well as SRI, but perform in manners equal or superior to conventional funds. These results show statistically significant in some cases.
Resumo:
Aim A recent Monte Carlo based study has shown that it is possible to design a diode that measures small field output factors equivalent to that in water. This is accomplished by placing an appropriate sized air gap above the silicon chip (1) with experimental results subsequently confirming that a particular Monte Carlo design was accurate (2). The aim of this work was to test if a new correction-less diode could be designed using an entirely experimental methodology. Method: All measurements were performed on a Varian iX at a depth of 5 cm, SSD of 95 cm and field sizes of 5, 6, 8, 10, 20 and 30 mm. Firstly, the experimental transfer of kq,clin,kq,msr from a commonly used diode detector (IBA, stereotactic field diode (SFD)) to another diode detector (Sun Nuclear, unshielded diode, (EDGEe)) was tested. These results were compared to Monte Carlo calculated values of the EDGEe. Secondly, the air gap above the EDGEe silicon chip was optimised empirically. Nine different air gap “tops” were placed above the EDGEe (air depth = 0.3, 0.6, 0.9 mm; air width = 3.06, 4.59, 6.13 mm). The sensitivity of the EDGEe was plotted as a function of air gap thickness for the field sizes measured. Results: The transfer of kq,clin,kq,msr from the SFD to the EDGEe was correct to within the simulation and measurement uncertainties. The EDGEe detector can be made “correction-less” for field sizes of 5 and 6 mm, but was ∼2% from being “correction-less” at field sizes of 8 and 10 mm. Conclusion Different materials will perturb small fields in different ways. A detector is only “correction-less” if all these perturbations happen to cancel out. Designing a “correction-less” diode is a complicated process, thus it is reasonable to expect that Monte Carlo simulations should play an important role.
Resumo:
Aim A new method of penumbral analysis is implemented which allows an unambiguous determination of field size and penumbra size and quality for small fields and other non-standard fields. Both source occlusion and lateral electronic disequilibrium will affect the size and shape of cross-axis profile penumbrae; each is examined in detail. Method A new method of penumbral analysis is implemented where the square of the derivative of the cross-axis profile is plotted. The resultant graph displays two peaks in the place of the two penumbrae. This allows a strong visualisation of the quality of a field penumbra, as well as a mathematically consistent method of determining field size (distance between the two peak’s maxima), and penumbra (full-widthtenth-maximum of peak). Cross-axis profiles were simulated in a water phantom at a depth of 5 cm using Monte Carlo modelling, for field sizes between 5 and 30 mm. The field size and penumbra size of each field was calculated using the method above, as well as traditional definitions set out in IEC976. The effect of source occlusion and lateral electronic disequilibrium on the penumbrae was isolated by repeating the simulations removing electron transport and using an electron spot size of 0 mm, respectively. Results All field sizes calculated using the traditional and proposed methods agreed within 0.2 mm. The penumbra size measured using the proposed method was systematically 1.8 mm larger than the traditional method at all field sizes. The size of the source had a larger effect on the size of the penumbra than did lateral electronic disequilibrium, particularly at very small field sizes. Conclusion Traditional methods of calculating field size and penumbra are proved to be mathematically adequate for small fields. However, the field size definition proposed in this study would be more robust amongst other nonstandard fields, such as flattening filter free. Source occlusion plays a bigger role than lateral electronic disequilibrium in small field penumbra size.
Resumo:
Aim The assessment of treatment plans is an important component in the education of radiation therapists. The establishment of a grade for a plan is currently based on subjective assessment of a range of criteria. The automation of assessment could provide a number of advantages including faster feedback, reduced chance of human error, and simpler aggregation of past results. Method A collection of treatments planned by a cohort of 27 second year radiation therapy students were selected for quantitative evaluation. Treatment sites included the bladder, cervix, larynx, parotid and prostate, although only the larynx plans had been assessed in detail. The plans were designed with the Pinnacle system and exported using the DICOM framework. Assessment criteria included beam arrangement optimisation, volume contouring, target dose coverage and homogeneity, and organ-at-risk sparing. The in-house Treatment and Dose Assessor (TADA) software1 was evaluated for suitability in assisting with the quantitative assessment of these plans. Dose volume data were exported in per-student and per-structure data tables, along with beam complexity metrics, dose volume histograms, and reports on naming conventions. Results The treatment plans were exported and processed using TADA, with the processing of all 27 plans for each treatment site taking less than two minutes. Naming conventions were successfully checked against a reference protocol. Significant variations between student plans were found. Correlation with assessment feedback was established for the larynx plans. Conclusion The data generated could be used to inform the selection of future assessment criteria, monitor student development, and provide useful feedback to the students. The provision of objective, quantitative evaluations of plan quality would be a valuable addition to not only radiotherapy education programmes but also for staff development and potentially credentialing methods. New functionality within TADA developed for this work could be applied clinically to, for example, evaluate protocol compliance.