76 resultados para Three-phase Four-wire Circuits

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work is a MATLAB/Simulink model of a controller for a three-phase, four-wire, grid-interactive inverter. The model provides capacity for simulating the performance of power electroinic hardware, as well as code generation for an embedded controller. The implemented hardware topology is a three-leg bridge with a neutral connection to the centre-tap of the DC bus. An LQR-based current controller and MAF-based phase detector are implemented. The model is configured for code generation for a Texas Instruments TMS320F28335 Digital Signal Processor (DSP).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

stract This paper proposes a hybrid discontinuous control methodology for a voltage source converter (VSC), which is used in an uninterrupted power supply (UPS) application. The UPS controls the voltage at the point of common coupling (PCC). An LC filter is connected at the output of the VSC to bypass switching harmonics. With the help of both filter inductor current and filter capacitor voltage control, the voltage across the filter capacitor is controlled. Based on the voltage error, the control is switched between current and voltage control modes. In this scheme, an extra diode state is used that makes the VSC output current discontinuous. This diode state reduces the switching losses. The UPS controls the active power it supplies to a three-phase, four-wire distribution system. This gives a full flexibility to the grid to buy power from the UPS system depending on its cost and load requirement at any given time. The scheme is validated through simulation using PSCAD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a longitudinal study, an overall behavioural model with three related phases (cognitive, motivational and volitional phase) across three studies was examined to identify the factors that most prominently drive consumer environmental behaviour. This thesis provides empirical evidence to support the behavioural model in an environmental consumption context and shows a new avenue for promoting consumer environmental behaviour.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper introduces the design of robust current and voltage control algorithms for a grid-connected three-phase inverter which is interfaced to the grid through a high-bandwidth three-phase LCL filter. The algorithms are based on the state feedback control which have been designed in a systematic approach and improved by using oversampling to deal with the issues arising due to the high-bandwidth filter. An adaptive loop delay compensation method has also been adopted to minimize the adverse effects of loop delay in digital controller and to increase the robustness of the control algorithm in the presence of parameter variations. Simulation results are presented to validate the effectiveness of the proposed algorithm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a modulation and controller design method for paralleled Z-source inverter systems applicable for alternative energy sources like solar cells, fuel cells, or variablespeed wind turbines with front-end diode rectifiers. A modulation scheme is designed based on simple shoot-through principle with interleaved carriers to give enhanced ripple reduction in the system. Subsequently, a control method is proposed to equalize the amount of power injected by the inverters in the grid-connected mode and also to provide reliable supply to sensitive loads onsite in the islanding mode. The modulation and controlling methods are proposed to have modular independence so that redundancy, maintainability, and improved reliability of supply can be achieved. The performance of the proposed paralleled Z-source inverter configuration is validated with simulations carried out using Matlab/Simulink/Powersim. Moreover, a prototype is built in the laboratory to obtain the experimental verifications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a novel three-phase to single-phase matrix converter (TSMC) based bi-directional inductive power transfer (IPT) system for vehicle-to-grid (V2G) applications. In contrast to existing techniques, the proposed technique which employs a TSMC to drive an 8th order high frequency resonant network, requires only a single-stage power conversion process to facilitate bi-directional power transfer between electric vehicles (EVs) and a three-phase utility power supply. A mathematical model is presented to demonstrate that both magnitude and direction of power flow can be controlled by regulating either relative phase angles or magnitudes of voltages generated by converters. The viability of the proposed mathematical model is verified using simulated results of a 10 kW bi-directional IPT system and the results suggest that the proposed system is efficient, reliable and is suitable for high power applications which require contactless power transfer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low voltage distribution networks feature a high degree of load unbalance and the addition of rooftop photovoltaic is driving further unbalances in the network. Single phase consumers are distributed across the phases but even if the consumer distribution was well balanced when the network was constructed changes will occur over time. Distribution transformer losses are increased by unbalanced loadings. The estimation of transformer losses is a necessary part of the routine upgrading and replacement of transformers and the identification of the phase connections of households allows a precise estimation of the phase loadings and total transformer loss. This paper presents a new technique and preliminary test results for a method of automatically identifying the phase of each customer by correlating voltage information from the utility's transformer system with voltage information from customer smart meters. The techniques are novel as they are purely based upon a time series of electrical voltage measurements taken at the household and at the distribution transformer. Experimental results using a combination of electrical power and current of the real smart meter datasets demonstrate the performance of our techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new technique is presented for automatically identifying the phase connection of domestic customers. Voltage information from a reference three phase house is correlated with voltage information from other customer electricity meters on the same network to determine the highest probability phase connection. The techniques are purely based upon a time series of electrical voltage measurements taken by the household smart meters and no additional equipment is required. The method is demonstrated using real smart meter datasets to correctly identify the phase connections of 75 consumers on a low voltage distribution feeder.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the design of a dual Z-source inverter that can be used with either a single dc source or two isolated dc sources. Unlike traditional inverters, the integration of a properly designed Z-source network and semiconductor switches to the proposed dual inverter allows buck-boost power conversion to be performed over a wide modulation range with three-level output waveforms generated. The connection of an additional transformer to the inverter ac output also allows all generic wye- or delta-connected loads with three-wire or four-wire configuration to be supplied by the inverter. Modulation-wise, the dual inverter can be controlled using a carefully designed carrier-based pulse-width modulation (PWM) scheme that always will ensure balanced voltage boosting of the Z-source network, while simultaneously achieving reduced common-mode switching. Because of the omission of dead-time delays in the dual inverter PWM scheme, its switched common-mode voltage can be completely eliminated, unlike in traditional inverters where narrow common-mode spikes are still generated. Under semiconductor failure conditions, the presented PWM schemes can easily be modified to allow the inverter to operate without interruption and for cases where two isolated sources are used, zero common-mode voltage can still be ensured. These theoretical findings together with the inverter practicality have been confirmed both in simulations using PSIM with Matlab/Simulink coupler and experimentally using a laboratory implemented inverter prototype.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the design of a dual Z-source inverter that can be used with either a single dc source or two isolated dc sources. Unlike traditional inverters, the integration of a properly designed Z-source network and semiconductor switches to the proposed dual inverter allows buck-boost power conversion to be performed over a wide modulation range, with three-level output waveforms generated. The connection of an additional transformer to the inverter ac output also allows all generic wye-or delta-connected loads with three-wire or four-wire configuration to be supplied by the inverter. Modulationwise, the dual inverter can be controlled using a carefully designed carrier-based pulsewidth-modulation (PWM) scheme that will always ensure balanced voltage boosting of the Z-source network while simultaneously achieving reduced common-mode switching. Because of the omission of dead-time delays in the dual-inverter PWM scheme, its switched common-mode voltage can be completely eliminated, unlike in traditional inverters, where narrow common-mode spikes are still generated. Under semiconductor failure conditions, the presented PWM schemes can easily be modified to allow the inverter to operate without interruption, and for cases where two isolated sources are used, zero common-mode voltage can still be ensured. These theoretical findings, together with the inverter practicality, have been confirmed in simulations both using PSIM with Matlab/Simulink coupler and experimentally using a laboratory-implemented inverter prototype.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The misuse of alcohol is well documented in Australia and has been associated with disorders and harms that often require police attention. The extent of alcohol-related incidents requiring police attention has been recorded as substantial in some Australian cities (Arro, Crook, & Fenton, 1992; Davey & French, 1995; Ireland & Thommeny, 1993). A significant proportion of harmful drinking occurs in and around licensed premises (Jochelson, 1997; Stockwell, Masters, Phillips, Daly, Gahegan, Midford, & Philp, 1998; Borges, Cherpitel, & Rosovsky, 1998) and most of these incidents are not reported to police (Bryant & Williams, 2000; Lister, Hobbs, Hall, & Winlow, 2000). Alcohol-related incidents have also been found to be concentrated in certain places at certain times (Jochelson, 1997) and therefore manipulating the context in which these incidents occur may provide a means to prevent and reduce the harm associated with alcohol misuse. One of the major objectives of the present program of research was to investigate the occurrence and resource impact of alcohol-related incidents on operational (general duties) policing across a large geographical area. A second objective of the thesis was to examine the characteristics and temporal/spatial dynamics of police attended alcohol incidents in the context of Place Based theories of crime. It was envisaged that this approach would reveal the patterns of the most prevalent offences and demonstrate the relevance of Place Based theories of crime to understanding these patterns. In addition, the role of alcohol, time and place were also explored in order to examine the association between non criminal traffic offences and other types of criminal offences. A final objective of the thesis was to examine the impact of a situational crime prevention strategy that had been initiated to reduce the violence and disorder associated with late-night liquor trading premises. The program of research in this doctorate thesis has been undertaken through the presentation of published papers. The research was conducted in three stages which produced six manuscripts, five of which were submitted to peer reviewed journals and one that was published in a peer reviewed conference proceedings. Stage One included two studies (Studies 1 & 2) both of which involved a cross sectional approach to examine the prevalence and characteristics of alcohol-related incidents requiring police attendance across three large geographical areas that included metropolitan cities, provincial regions and rural areas. Stage Two of the program of research also comprised two cross sectional quantitative studies (Studies 3 & 4) that investigated the temporal and spatial dynamics of the major offence categories attended by operational police in a specific Police District (Gold Coast). Stage Three of the program of research involved two studies (Studies 5 & 6) that assessed the effectiveness of a situational crime prevention strategy. The studies employed a pre-post design to assess the impact on crime, disorder and violence by preventing patrons from entering late-night liquor trading premises between 3 a.m. and 5 a.m. (lockout policy). Although Study Five was solely quantitative in nature, Study Six included both quantitative and qualitative aspects. The approach adopted in Study Six, therefore facilitated not only a quantative comparison of the impact of the lockout policy on different policing areas, but also enabled the processes related to the implementation of the lockout policy to be examined. The thesis reports a program of research involving a common data collection method which then involved a series of studies being conducted to explore different aspects of the data. The data was collected from three sources. Firstly a pilot phase was undertaken to provide participants with training. Secondly a main study period was undertaken immediately following the pilot phase. The first and second sources of data were collected between 29th March 2004 and 2nd May 2004. Thirdly, additional data was collected between the 1st April 2005 and 31st May 2005. Participants in the current program of research were first response operational police officers who completed a modified activity log over a 9 week period (4 week pilot phase & 5 week survey study phase), identifying the type, prevalence and characteristics of alcohol-related incidents that were attended. During the study period police officers attended 31,090 alcohol-related incidents. Studies One and Two revealed that a substantial proportion of current police work involves attendance at alcohol-related incidents (i.e., 25% largely involving young males aged between 17 and 24 years). The most common incidents police attended were vehicle and/or traffic matters, disturbances and offences against property. The major category of offences most likely to involve alcohol included vehicle/traffic matters, disturbances and offences against the person (e.g., common & serious assaults). These events were most likely to occur in the late evenings and early hours of the morning on the weekends, and importantly, usually took longer for police to complete than non alcohol-related incidents. The findings in Studies Three and Four suggest that serious traffic offences, disturbances and offences against the person share similar characteristics and occur in concentrated places at similar times. In addition, it was found that time, place and incident type all have an influence on whether an incident attended by a police officer is alcohol-related. Alcohol-related incidents are more likely to occur in particular locations in the late evenings and early mornings on the weekends. In particular, there was a strong association between the occurrence of alcohol-related disturbances and alcohol-related serious traffic offences in regards to place and time. In general, stealing and property offences were not alcohol-related and occurred in daylight hours during weekdays. The results of Studies Five and Six were mixed. A number of alcohol-related offences requiring police attention were significantly reduced for some policing areas and for some types of offences following the implementation of the lockout policy. However, in some locations the lockout policy appeared to have a negative or minimal impact. Interviews with licensees revealed that although all were initially opposed to the lockout policy as they believed it would have a negative impact on business, most perceived some benefits from its introduction. Some of the benefits included, improved patron safety and the development of better business strategies to increase patron numbers. In conclusion, the overall findings of the six studies highlight the pervasive nature of alcohol across a range of criminal incidents, demonstrating the tremendous impact alcohol-related incidents have on police. The findings also demonstrate the importance of time and place in predicting the occurrence of alcohol-related offences. Although this program of research did not set out to test Place Based theories of crime, these theories were used to inform the interpretation of findings. The findings in the current research program provide evidence for the relevance of Place Based theories of crime to understanding the factors contributing to violence and disorder, and designing relevant crime prevention strategies. For instance, the results in Studies Five and Six provide supportive evidence that this novel lockout initiative can be beneficial for public safety by reducing some types of offences in particular areas in and around late-night liquor trading premises. Finally, intelligent-led policing initiatives based on problem oriented policing, such as the lockout policy examined in this thesis, have potential as a major crime prevention technique to reduce specific types of alcohol-related offences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multilevel inverters provide an attractive solution for power electronics when both reduced harmonic contents and high voltages are required. In this paper, a novel predictive current control technique is proposed for a three-phase multilevel inverter, which controls the capacitors voltages and load currents with low switching losses. The advantage of this contribution is that the technique can be applied to more voltage levels without significantly changing the control circuit. The three-phase three-level inverter with a pure inductive load has been implemented to track reference currents using analogue circuits and programmable logic device.