27 resultados para TRANSTHORACIC ENDOSCOPIC SYMPATHECTOMY
em Queensland University of Technology - ePrints Archive
Resumo:
A prospective, consecutive series of 106 patients receiving endoscopic anterior scoliosis correction. The aim was to analyse changes in radiographic parameters and rib hump in the two years following surgery. Endoscopic anterior scoliosis correction is a level sparing approach, therefore it is important to assess the amount of decompensation which occurs after surgery. All patients received a single anterior rod and vertebral body screws using a standard compression technique. Cleared disc spaces were packed with either mulched femoral head allograft or rib head/iliac crest autograft. Radiographic parameters (major, instrumented, minor Cobb, T5-T12 kyphosis) and rib hump were measured at 2,6,12 and 24 months after surgery. Paired t-tests and Wilcoxon signed ranks tests were used to assess the statistical significant of changes between adjacent time intervals.----- Results: Mean loss of major curve correction from 2 to 24 months after surgery was 4 degrees. Mean loss of rib hump correction was 1.4 degrees. Mean sagittal kyphosis increased from 27 degrees at 2 months to 30.6 degrees at 24 months. Rod fractures and screw-related complications resulted in several degrees less correction than patients without complications, but overall there was no clinically significant decompensation following complications. The study concluded that there are small changes in deformity measures after endoscopic anterior scoliosis surgery, which are statistically significant but not clinically significant.
Resumo:
Bone graft is generally considered fundamental in achieving solid fusion in scoliosis correction and pseudarthrosis following instrumentation may predispose to implant failure. In endoscopic anterior-instrumented scoliosis surgery, autologous rib or iliac crest graft has been utilised traditionally but both techniques increase operative duration and cause donor site morbidity. Allograft bone and bone- morphogenetic-protein alternatives may improve fusion rates but this remains controversial. This study's objective was to compare two-year postoperative fusion rates in a series of patients who underwent endoscopic anterior instrumentation for thoracic scoliosis utilising various bone graft types. Significantly better rates of fusion occurred in endoscopic anterior instrumented scoliosis correction using femoral allograft compared to autologous rib-heads and iliac crest graft. This may be partly explained by the difficulty obtaining sufficient quantities of autologous graft. Lower fusion rates in the autologous graft group appeared to predispose to rod fracture although the clinical consequence of implant failure is uncertain.
Resumo:
Thoracoscopic instrumented anterior spinal fusion for adolescent idiopathic scoliosis (AIS) has clinical benefits that include reduced pulmonary morbidity, postoperative pain, and improved cosmesis. However, quantitative data on radiological improvement of vertebral rotation using this method is lacking. This study’s objectives were to measure preoperative and postoperative axial vertebral rotational deformity at the curve apex in endoscopically-treated anterior-instrumented scoliosis patients using CT, and assess the relevance of these findings to clinically measured chest wall rib hump deformity correction. This is the first quantitative CT study to confirm that endoscopic anterior instrumented fusion for AIS substantially improves axial vertebral body rotational deformity at the apex of the curve. The margin of correction of 43% compares favourably with historically published figures of 24% for patients with posterior all-hook-rod constructs. CT measurements correlated significantly to the clinical outcome of rib hump deformity correction.
Resumo:
Endoscopic approaches for anterior correction of idiopathic scoliosis are a relatively new surgical technique. This paper describes the development of patient-specific finite element modelling techniques to investigate the biomechanics of single rod anterior scoliosis correction. Spinal geometry is obtained from pre-operative CT scans and material properties for osteo-ligamentous spinal tissues are based on existing literature. The techniques being developed will allow pre-surgical prediction of stresses, forces and deformations in spinal tissues, rods and screws under post-operative physiological loads.
Resumo:
Endoscopic (thoracoscopic) scoliosis correction plays an important part in the surgical options available for treating adolescent idiopathic scoliosis. However, there is a paucity of literature examining optimum methods of analgesia following this type of surgery. Intra-pleural analgesia has been successfully used following cardiothoracic procedures [1-3]. The role of intra-pleural analgesia after keyhole anterior selective thoracic scoliosis correction is examined and described.
Resumo:
Echocardiography is the commonest form of non-invasive cardiac imaging and is fundamental to patient management. However, due to its methodology, it is also operator dependent. There are well defined pathways in training and ongoing accreditation to achieve and maintain competency. To satisfy these requirements, significant time has to be dedicated to scanning patients, often in the time pressured clinical environment. Alternative, computer based training methods are being considered to augment echocardiographic training. Numerous advances in technology have resulted in the development of interactive programmes and simulators to teach trainees the skills to perform particular procedures, including transthoracic and transoesophageal echocardiography. 82 sonographers and TOE proceduralists utilised an echocardiographic simulator and assessed its utility using defined criteria. 40 trainee sonographers assessed the simulator and were taught how to obtain an apical 2 chamber (A2C) view and image the superior vena cava (SVC). 100% and 88% found the simulator useful in obtaining the SVC or A2C view respectively. All users found it easy to use and the majority found it helped with image acquisition and interpretation. 42 attendees of a TOE training day utilising the simulator assessed the simulator with 100% finding it easy to use, as well as the augmented reality graphics benefiting image acquisition. 90% felt that it was realistic. This study revealed that both trainee sonographers and TOE proceduralists found the simulation process was realistic, helped in image acquisition and improved assessment of spatial relationships. Echocardiographic simulators may play an important role in the future training of echocardiographic skills.
Resumo:
Endoscopic scoliosis correction plays an important part in the surgical options available for treating adolescent idiopathic scoliosis. However, there is a paucity of literature examining optimum methods of analgesia following this type of surgery. The role of intrapleural analgesia is examined and described. In this study, local anaesthetic administration via an intrapleural catheter was found to be a safe and effective method of analgesia following endoscopic scoliosis correction. Post-operative pain following anterior scoliosis correction can be reduced to ‘mild’ levels by combined analgesia regimes. Surgeons may wish to expand its use into open or minimally invasive anterior scoliosis correction or anterior releases.
Resumo:
Introduction. Endoscopic anterior scoliosis correction has been employed recently as a less invasive and level-sparing approach compared with open surgical techniques. We have previously demonstrated that during the two-year post-operative period, there was a mean loss of rib hump correction by 1.4 degrees. The purpose of this study was to determine whether intra- or inter-vertebral rotational deformity during the post-operative period could account for the loss of rib hump correction. Materials and Methods. Ten consecutive patients diagnosed with adolescent idiopathic scoliosis were treated with an endoscopic anterior scoliosis correction. Low-dose computed tomography scans of the instrumented segment were obtained post-operatively at 6 and 24 months following institutional ethical approval and patient consent. Three-dimensional multi-planar reconstruction software (Osirix Imaging Software, Pixmeo, Switzerland) was used to create axial slices of each vertebral level, corrected in both coronal and sagittal planes. Vertebral rotation was measured using Ho’s method for every available superior and inferior endplate at 6 and 24 months. Positive changes in rotation indicate a reduction and improvement in vertebral rotation. Intra-observer variability analysis was performed on a subgroup of images. Results. Mean change in rotation for vertebral endplates between 6 and 24 months post-operatively was -0.26˚ (range -3.5 to 4.9˚) within the fused segment and +1.26˚ (range -7.2 to 15.1˚) for the un-instrumented vertebrae above and below the fusion. Mean change in clinically measured rib hump for the 10 patients was -1.6˚ (range -3 to 0˚). The small change in rotation within the fused segment accounts for only 16.5% of the change in rib hump measured clinically whereas the change in rotation between the un-instrumented vertebrae above and below the construct accounts for 78.8%. There was no clear association between rib hump recurrence and intra- or inter-vertebral rotation in individual patients. Intra-rater variability was ± 3˚. Conclusions. Intra- and inter-vertebral rotation continues post-operatively both within the instrumented and un-instrumented segments of the immature spine. Rotation between the un-instrumented vertebrae above and below the fusion was +1.26˚, suggesting that the un-instrumented vertebrae improved and de-rotated slightly after surgery. This may play a role in rib hump recurrence, however this remains clinically insignificant.
Resumo:
Background: Transthoracic echocardiography (TTE) during extra corporeal membrane oxygenation (ECMO) is important but can be technically challenging. Contrast-specific TTE can improve imaging in suboptimal studies. These contrast microspheres are hydrodynamically labile structures. This study assessed the feasibility of contrast echocardiography (CE) during venovenous (VV) ECMO in a validated ovine model. Method: Twenty-four sheep were commenced on VV ECMO. Parasternal long-axis (Plax) and short-axis (Psax) views were obtained pre- and postcontrast while on VV ECMO. Endocardial definition scores (EDS) per segment were graded: 1 = good, 2 = suboptimal 3 = not seen. Endocardial border definition score index (EBDSI) was calculated for each view. Endocardial length (EL) in the Plax view for the left ventricle (LV) and right ventricle (RV) was measured. Results: Summation EDS data for the LV and RV for unenhanced TTE (UE) versus CE TTE imaging: EDS 1 = 289 versus 346, EDS 2 = 38 versus 10, EDS 3 = 33 versus 4, respectively. Wilcoxon matched-pairs rank-sign tests showed a significant ranking difference (improvement) pre- and postcontrast for the LV (P < 0.0001), RV (P < 0.0001) and combined ventricular data (P < 0.0001). EBDSI for CE TTE was significantly lower than UE TTE for the LV (1.05 ± 0.17 vs. 1.22 ± 0.38, P = 0.0004) and RV (1.06 ± 0.22 vs. 1.42 ± 0.47, P = 0.0.0006) respectively. Visualized EL was significantly longer in CE versus UE for both the LV (58.6 ± 11.0 mm vs. 47.4 ± 11.7 mm, P < 0.0001) and the RV (52.3 ± 8.6 mm vs. 36.0 ± 13.1 mm, P < 0.0001), respectively. Conclusions: Despite exposure to destructive hydrodynamic forces, CE is a feasible technique in an ovine ECMO model. CE results in significantly improved EDS and increased EL.
Resumo:
Study Design: Biomechanical testing of vertebral body screw pullout resistance with relevance to top screw pullout in endoscopic anterior scoliosis constructs. Objectives: To analyse the effect of screw positioning and angulation on pullout resistance of vertebral body screws, where the pullout takes place along a curved path as occurs in anterior scoliosis constructs. Summary of Background Data: Top screw pullout is a significant clinical problem in endoscopic anterior scoliosis surgery, with rates of up to 18% reported in the literature. Methods: A custom designed biomechanical test rig was used to perform pullout tests of Medtronic anterior vertebral screws where the pullout occurred along an arc of known radius. Using synthetic bone blocks, a range of pullout radii and screw angulations were tested, in order to determine an ‘optimal’ configuration. The optimal configuration was then compared with standard screw positioning using a series of tests on ovine vertebrae (n=29). Results: Screw angulation has a small but significant effect on pullout resistance, with maximum strength being achieved at 10 degree cephalad angulation. Combining 10 degree cephalad angulation with maximal spacing between the top two screws (maximum pullout radius) increased the pullout resistance by 88% compared to ‘standard’ screw positioning (screws inserted perpendicular to rod at mid-body height). Conclusions: The positioning of the top screw in anterior scoliosis constructs can significantly alter its pullout resistance.
Resumo:
Adolescent Idiopathic Scoliosis (AIS) has been associated with reduced pulmonary function believed to be due to a restriction of lung volume by the deformed thoracic cavity. A recent study by our group examined the changes in lung volume pre and post anterior thoracoscopic scoliosis correction using pulmonary function testing (1), however the anatomical changes in ribcage shape and left/right lung volume after thoracoscopic surgery which govern overall respiratory capacity are unknown. The aim of this study was to use 3D rendering from CT scan data to compare lung and ribcage anatomical changes from pre to two years post thoracoscopic anterior scoliosis correction. The study concluded that 3D volumetric reconstruction from CT scans is a powerful means of evaluating changes in pulmonary and thoracic anatomy following surgical AIS correction. Most likely, lung volume changes following thoracoscopic scoliosis correction are multifactorial and affected by changes in height (due to residual growth), ribcage shape, diaphragm positioning, Cobb angle correction in the thoracic spine. Further analysis of the 3D reconstructions will be performed to assess how each of these factors affect lung volume in this patient cohort.
Resumo:
Throughout history, developments in medicine have aimed to improve patient quality of life, and reduce the trauma associated with surgical treatment. Surgical access to internal organs and bodily structures has been traditionally via large incisions. Endoscopic surgery presents a technique for surgical access via small (1 Omm) incisions by utilising a scope and camera for visualisation of the operative site. Endoscopy presents enormous benefits for patients in terms of lower post operative discomfort, and reduced recovery and hospitalisation time. Since the first gall bladder extraction operation was performed in France in 1987, endoscopic surgery has been embraced by the international medical community. With the adoption of the new technique, new problems never previously encountered in open surgery, were revealed. One such problem is that the removal of large tissue specimens and organs is restricted by the small incision size. Instruments have been developed to address this problem however none of the devices provide a totally satisfactory solution. They have a number of critical weaknesses: -The size of the access incision has to be enlarged, thereby compromising the entire endoscopic approach to surgery. - The physical quality of the specimen extracted is very poor and is not suitable to conduct the necessary post operative pathological examinations. -The safety of both the patient and the physician is jeopardised. The problem of tissue and organ extraction at endoscopy is investigated and addressed. In addition to background information covering endoscopic surgery, this thesis describes the entire approach to the design problem, and the steps taken before arriving at the final solution. This thesis contributes to the body of knowledge associated with the development of endoscopic surgical instruments. A new product capable of extracting large tissue specimens and organs in endoscopy is the final outcome of the research.
Resumo:
The relationship between radiologic union and clinical outcome in thoracoscopic scoliosis surgery is not clear, as apparent non-union of a spinal fusion does not always correspond to a poor clinical result. The aim of this study was to evaluate CT fusion rates 24 months after thoracoscopic anterior scoliosis surgery, and to explore the relationship between fusion scores and; (i) rod diameter, (ii) graft type, (iii) fusion level, (iv) occurrence of post-operative implant failure, and (v) lateral position of the fusion mass in the intervertebral disc space. We propose that moderate fusion scores on the Sucato scale secure successful clinical outcomes in thoracoscopic scoliosis surgery.