89 resultados para Sports facilities -- Heating and ventilation
em Queensland University of Technology - ePrints Archive
Resumo:
Spaces without northerly orientations have an impact on the ‘energy behaviour’ of a building. This paper outlines possible energy savings and better performance achieved by different zenithal solar passive strategies (skylights, roof monitors and clerestory roof windows) and element arrangements across the roof in zones of cold to temperate climates typical of the central and central-southern Argentina. Analyses were undertaken considering daylighting, thermal and ventilation performances of the different strategies. The results indicate that heating,ventilation and lighting loads in spaces without an equator-facing facade can be significantly reduced by implementing solar passive strategies. In the thermal aspect, the solar saving fraction reached for the different strategies were averaged 43.16% for clerestories, 41.4% for roof monitors and 38.86% for skylights for a glass area of 9% to the floor area. The results also indicate average illuminance levels above 500 lux for the different clerestory and monitor arrangements, uniformity ratios of 0.66–0.82 for the most distributed arrangements and day-lighting factors between 11.78 and 20.30% for clear sky conditions, depending on the strategy. In addition, minimum air changes rates of 4 were reached for the most extreme conditions.
Resumo:
Unsteady natural convection due to differentially heating of the sinusoidal corrugated side walls of a modified square enclosure has been numerically investigated. The fluid inside the enclosure is air, initially as quiescent. The flat top and bottom surfaces are considered as adiabatic. The numerical scheme is based on the finite element method adapted to triangular non-uniform mesh element by a non-linear parametric solution algorithm. The results are obtained for the Rayleigh number, Ra ranging from 1e+05 to 1e+08 for different corrugation amplitude and frequency with constant physical properties for the fluid medium considered. The streamlines, isotherms and average Nusselt numbers are presented to observe the effect of sudden heating and its consequent transient behavior on fluid flow and heat transfer characteristics for the range of governing parameters. The present results show that the transient phenomena are greatly influenced by the variation of the aforementioned parameters.
Resumo:
Plasma sheath, nanostructure growth, and thermal models are used to describe carbon nanofiber (CNF) growth and heating in a low-temperature plasma. It is found that when the H2 partial pressure is increased, H atom recombination and H ion neutralization are the main mechanisms responsible for energy release on the catalyst surface. Numerical results also show that process parameters such as the substrate potential, electron temperature and number density mainly affect the CNF growth rate and plasma heating at low catalyst temperatures. In contrast, gas pressure, ion temperature, and the C2H2:H2 supply ratio affect the CNF growth at all temperatures. It is shown that plasma-related processes substantially increase the catalyst particle temperature, in comparison to the substrate and the substrate-holding platform temperatures.
Resumo:
The possibility of independent control of the surface fluxes of energy and hydrogen-containing radicals, thus enabling selective control of the nanostructure heating and passivation, is demonstrated. In situ energy flux measurements reveal that even a small addition of H2 to low-pressure Ar plasmas leads to a dramatic increase in the energy deposition through H recombination on the surface. The heat release is quenched by a sequential addition of a hydrocarbon precursor while the surface passivation remains effective. Such selective control offers an effective mechanism for deterministic control of the growth shape, crystallinity, and density of nanostructures in plasma-aided nanofabrication. © 2010 American Institute of Physics.
Resumo:
This article presents the results on the diagnostics and numerical modeling of low-frequency (∼460 KHz) inductively coupled plasmas generated in a cylindrical metal chamber by an external flat spiral coil. Experimental data on the electron number densities and temperatures, electron energy distribution functions, and optical emission intensities of the abundant plasma species in low/intermediate pressure argon discharges are included. The spatial profiles of the plasma density, electron temperature, and excited argon species are computed, for different rf powers and working gas pressures, using the two-dimensional fluid approach. The model allows one to achieve a reasonable agreement between the computed and experimental data. The effect of the neutral gas temperature on the plasma parameters is also investigated. It is shown that neutral gas heating (at rf powers≥0.55kW) is one of the key factors that control the electron number density and temperature. The dependence of the average rf power loss, per electron-ion pair created, on the working gas pressure shows that the electron heat flux to the walls appears to be a critical factor in the total power loss in the discharge.
Resumo:
The low temperature operation of a heat pump makes it an excellent match for the use of solar energy. At the National University of Singapore, a solar assisted heat pump system has been designed, fabricated and installed to provide water heating and drying. The system also utilizes the air con waste heat, which would normally be released to atmosphere adding to global warming. Experimental results show that the twophase unglazed solar evaporator-collector, instead of losing energy to the ambient, gained a significant amount due to low operating temperature of the collector. As a result, the collector efficiency attains a value greater than 1, when conventional collector equations are used. With this evaporator-collector, the system can be operated even in the absence of solar irradiation. The waste heat was collected from an air-con system, which maintained a room at 20-22 oC. In the condenser side, water at 60 oC was produced at a rate of 3 liter/minute and the drying capacity was 2.2kg/hour. Maximum COP of the system was found to be about 5.5.
Resumo:
Background Medication incident reporting (MIR) is a key safety critical care process in residential aged care facilities (RACFs). Retrospective studies of medication incident reports in aged care have identified the inability of existing MIR processes to generate information that can be used to enhance residents’ safety. However, there is little existing research that investigates the limitations of the existing information exchange process that underpins MIR, despite the considerable resources that RACFs’ devote to the MIR process. The aim of this study was to undertake an in-depth exploration of the information exchange process involved in MIR and identify factors that inhibit the collection of meaningful information in RACFs. Methods The study was undertaken in three RACFs (part of a large non-profit organisation) in NSW, Australia. A total of 23 semi-structured interviews and 62 hours of observation sessions were conducted between May to July 2011. The qualitative data was iteratively analysed using a grounded theory approach. Results The findings highlight significant gaps in the design of the MIR artefacts as well as information exchange issues in MIR process execution. Study results emphasized the need to: a) design MIR artefacts that facilitate identification of the root causes of medication incidents, b) integrate the MIR process within existing information systems to overcome key gaps in information exchange execution, and c) support exchange of information that can facilitate a multi-disciplinary approach to medication incident management in RACFs. Conclusions This study highlights the advantages of viewing MIR process holistically rather than as segregated tasks, as a means to identify gaps in information exchange that need to be addressed in practice to improve safety critical processes.
Resumo:
Extreme sports and extreme sports participants have been most commonly explored from a negative perspective, for example the “need to take unnecessary risks.” This study explored what can be learned from extreme sports about courage and humility - two positive psychology constructs. A phenomenological method was used via unstructured interviews with 15 extreme sports participants and other first hand accounts. The extreme sports included B.A.S.E. jumping, big wave surfing, extreme skiing, waterfall kayaking, extreme mountaineering and solo rope-free climbing. Results indicate that humility and courage can be deliberately sought out by participating in activities that involve a real chance of death, fear and the realisation that nature in its extreme is far greater and more powerful than humanity.
Resumo:
Australian Universities are very successful in attracting large number of international students. A large proportion of University revenue comes from the full fee paying international students. However, there have been many reports that international students face numerous problems when they arrive in Australia. The common management practice is to provide support staff services to deal with the orientation and welfare of international students. Such service units act as intermediaries between the students and the teaching and learning community of the university. However, the actual experience of international students may be difficult for support staff, counsellors, advisers and academic staff to anticipate. There is little information on the actual experience of students relative to their expectations. This study aimed at securing a deeper understanding of the contextually relevant issues facing by international students in Australian universities in order to develop management strategies aimed at improved teaching and learning outcomes for international students. Using a highly reliable survey questionnaire, a questionnaire survey was conducted among the international students at Queensland University of Technology (QUT), Brisbane, Australia. About 180 engineering students responded in the survey resulting in a response rate of 81%. Results indicate that international students face many difficulties including understanding colloquial language, Australian accent, cost of tuition, feelin isolation, safety, security, health services, accommodation and part time jobs. They also face difficulty in coping with learning methods in Australia, particularly in research report writing. However, they are happy with their lecturers and find them very helpful. Many of the students lacked the information regarding various community groups, recreational and sports facilities in Australia before arriving. Findings of the study show that there is a significant gap between the expectation of the students before coming to Australia and actual experience they experience here. Importantly, there is a lack of coordination between international students, international student services (ISS) and university management and as a consequence there have been little improvement in conditions. There is no direct link between student experience and University management. Many important suggestions arisen from this study and most important suggestion is that the student information system should be integrated with the University enterprise resource planning (ERP) to reduce the huge gap between international student expectation and actual experiences.
Resumo:
The natural convection thermal boundary layer adjacent to an inclined flat plate subject to sudden heating and a temperature boundary condition which follows a ramp function up until a specified time and then remains constant is investigated. The development of the flow from start-up to a steady-state has been described based on scaling analyses and verified by numerical simulations. Different flow regimes based on the Rayleigh number are discussed with numerical results for both boundary conditions. For ramp heating, the boundary layer flow depends on the comparison of the time at which the ramp heating is completed and the time at which the boundary layer completes its growth. If the ramp time is long compared with the steady state time, the layer reaches a quasi steady mode in which the growth of the layer is governed solely by the thermal balance between convection and conduction. On the other hand, if the ramp is completed before the layer becomes steady; the subsequent growth is governed by the balance between buoyancy and inertia, as for the case of instantaneous heating.
Resumo:
Introduction Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship. Methods Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared. Results Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort. Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion. When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions. Conclusions The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.
Resumo:
Twitter and other social media have become increasingly important tools for maintaining the relationships between fans and their idols across a range of activities, from politics and the arts to celebrity and sports culture. Twitter, Inc. itself has initiated several strategic approaches, especially to entertainment and sporting organisations; late in 2012, for example, a Twitter, Inc. delegation toured Australia in order to develop formal relationships with a number of key sporting bodies covering popular sports such as Australian Rules Football, A-League football (soccer), and V8 touring car racing, as well as to strengthen its connections with key Australian broadcasters and news organisations (Jackson & Christensen, 2012). Similarly, there has been a concerted effort between Twitter Germany and the German Bundesliga clubs and football association to coordinate the presence of German football on Twitter ahead of the 2012–2013 season: the Twitter accounts of almost all first-division teams now bear the official Twitter verification mark, and a system of ‘official’ hashtags for tweeting about individual games (combining the abbreviations of the two teams, e.g. #H96FCB) has also been instituted (Twitter auf Deutsch, 2012).
Resumo:
The aim of this work was to investigate changes in particle number concentration (PNC) within naturally ventilated primary school classrooms arising from local sources either within or adjacent to the classrooms. We quantify the rate at which ultrafine particles were emitted either from printing, grilling, heating or cleaning activities and the rate at which the particles were removed by both deposition and air exchange processes. At each of 25 schools in Brisbane, Australia, two weeks of measurements of PNC and CO2 were taken both outdoors and in the two classrooms. Bayesian regression modelling was employed in order to estimate the relevant rates and analyse the relationship between air exchange rate (AER), particle infiltration and the deposition rates of particle generated from indoor activities in the classrooms. During schooling hours, grilling events at the school tuckshop as well as heating and printing in the classrooms led to indoor PNCs being elevated by a factor of more than four, with emission rates of (2.51 ± 0.25) x 1011 p min-1, (8.99 ± 6.70) x 1011 p min-1 and (5.17 ± 2.00) x 1011 p min-1, respectively. During non-school hours, cleaning events elevated indoor PNC by a factor of above five, with an average emission rate of (2.09 ± 6.30) x 1011 p min-1. Particles were removed by both air exchange and deposition; chiefly by ventilation when AER > 0.7 h-1 and by deposition when AER < 0.7 h-1.