212 resultados para Skin dose

em Queensland University of Technology - ePrints Archive


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Stereotactic radiosurgery treatments involve the delivery of very high doses for a small number of fractions. To date, there is limited data in terms of the skin dose for the very small field sizes used in these treatments. In this work, we determine relative surface doses for small size circular collimators as used in stereotactic radiosurgery treatments. Monte Carlo calculations were performed using the BEAMnrc code with a model of the Novalis 15 Trilogy linear accelerator and the BrainLab circular collimators. The surface doses were calculated at the ICRU skin dose depth of 70 m all using the 6 MV SRS x-ray beam. The calculated surface doses varied between 15 – 12% with decreasing values as the field size increased from 4 to 30 mm. In comparison, surface doses were measured using Gafchromic EBT3 film positioned at the surface of a Virtual Water phantom. The absolute agreement between calculated and measured surface doses was better than 2.5% which is well within the 20 uncertainties of the Monte Carlo calculations and the film measurements. Based on these results, we have shown that the Gafchromic EBT3 film is suitable for surface dose estimates in very small size fields as used in SRS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction The dose to skin surface is an important factor for many radiotherapy treatment techniques. It is known that TPS predicted surface doses can be significantly different from actual ICRP skin doses as defined at 70 lm. A number of methods have been implemented for the accurate determination of surface dose including use of specific dosimeters such as TLDs and radiochromic film as well as Monte Carlo calculations. Stereotactic radiosurgery involves delivering very high doses per treatment fraction using small X-ray fields. To date, there has been limited data on surface doses for these very small field sizes. The purpose of this work is to evaluate surface doses by both measurements and Monte Carlo calculations for very small field sizes. Methods All measurements were performed on a Novalis Tx linear accelerator which has a 6 MV SRS X-ray beam mode which uses a specially thin flattening filter. Beam collimation was achieved by circular cones with apertures that gave field sizes ranging from 4 to 30 mm at the isocentre. The relative surface doses were measured using Gafchromic EBT3 film which has the active layer at a depth similar to the ICRP skin dose depth. Monte Carlo calculations were performed using the BEAMnrc/EGSnrc Monte Carlo codes (V4 r225). The specifications of the linear accelerator, including the collimator, were provided by the manufacturer. Optimisation of the incident X-ray beam was achieved by an iterative adjustment of the energy, spatial distribution and radial spread of the incident electron beam striking the target. The energy cutoff parameters were PCUT = 0.01 MeV and ECUT = 0.700 - MeV. Directional bremsstrahlung splitting was switched on for all BEAMnrc calculations. Relative surface doses were determined in a layer defined in a water phantom of the same thickness and depth as compared to the active later in the film. Results Measured surface doses using the EBT3 film varied between 13 and 16 % for the different cones with an uncertainty of 3 %. Monte Carlo calculated surface doses were in agreement to better than 2 % to the measured doses for all the treatment cones. Discussion and conclusions This work has shown the consistency of surface dose measurements using EBT3 film with Monte Carlo predicted values within the uncertainty of the measurements. As such, EBT3 film is recommended for in vivo surface dose measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Excessive exposure to ultraviolet (UV) radiation from sunlight is a causative factor in the development of skin damage and skin cancer. Little research has been undertaken into assessing the sun exposure linking to skin damage inside buildings or behind window glass. This project directly addressed this issue by aiming to assess the role that UV exposure has on skin damage for indoor workers and drivers. Methods: Measurements of personal UV exposure using UV sensitive polymer dosimeters were undertaken of 41 indoor workers and 3 professional drivers. Physical measurements of skin characteristics including skin pigmentation and UV induced skin photoaging were also determined. In addition, demographic information along with phenotypic characteristics, sun exposure and sun protection practice history, and history of skin damage were assessed through a questionnaire. Results: Indoor workers typically received low doses of UV radiation. However, one driver received a high dose (13J/cm2 UVA and 4.99 MED UVB on the arm). Age and years residing in Australia had a positive correlation with UV induced skin pigmentation. The number of major sunburns before 18 years was a risk factor for skin damage in adults. Those participants with fair skin, non-black hair and blue/green /blue-grey eye were more likely to have skin damage related to sun exposure. Conclusions: A person’s age, years residing in Australia, numbers of major sunburn, skin colour, hair colour and eye colour are important factors associated with the development of sun-related skin damage in workers. ‘Real World’ implications: 1. The number of major sunburns before 18 years was a risk factor for skin damage in adults. This clearly confirms the importance of early prevention. To protect the skin from extensive sun exposure for your generation should have significance for further prevention of skin damage. 2. It is unsurprising that age and years residing in Australia were associated with skin damage related UV radiation. Therefore, the general public should reinforce their sun protective measures and check skin regularly. 3. Drivers should take sun protective measures during their working hours between sunrise and sunset.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Air pollution is a widespread health problem associated with respiratory symptoms. Continuous exposure monitoring was performed to estimate alveolar and tracheobronchial dose, measured as deposited surface area, for 103 children and to evaluate the long-term effects of exposure to airborne particles through spirometry, skin prick tests and measurement of exhaled nitric oxide (eNO). The mean daily alveolar deposited surface area dose received by children was 1.35×103 mm2. The lowest and highest particle number concentrations were found during sleeping and eating time. A significant negative association was found between changes in pulmonary function tests and individual dose estimates. Significant differences were found for asthmatics, children with allergic rhinitis and sensitive to allergens compared to healthy subjects for eNO. Variation is a child’s activity over time appeared to have a strong impact on respiratory outcomes, which indicates that personal monitoring is vital for assessing the expected health effects of exposure to particles.