184 resultados para Short implant

em Queensland University of Technology - ePrints Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is likely that effective application of cell-laden implants for cartilage defects depends on retention of implanted cells and interaction between implanted and host cells. The objectives of this study were to characterize stratified cartilaginous constructs seeded sequentially with superficial (S) and middle (M) chondrocyte subpopulations labelled with fluorescent cell tracking dye PKH26 (*) and determine the degree to which these stratified cartilaginous constructs maintain their architecture in vivo after implantation in mini-pigs for 1 week. Alginate-recovered cells were seeded sequentially to form stratified S*/M (only S cells labelled) and S*/M* (both S and M cells labelled) constructs. Full-thickness defects (4 mm diameter) were created in the patellofemoral groove of adult Yucatan mini-pigs and filled with portions of constructs or left empty. Constructs were characterized biochemically, histologically, and biomechanically, and stratification visualized and quantified, before and after implant. After 1 week, animals were sacrificed and implants retrieved. After 1 week in vivo, glycosaminoglycan and collagen content of constructs remained similar to that at implant, whereas DNA content increased. Histological analyses revealed features of an early repair response, with defects filled with tissues containing little matrix and abundant cells. Some implanted (PKH26-labeled) cells persisted in the defects, although constructs did not maintain a stratified organization. Of the labelled cells, 126 +/- 38% and 32 +/- 8% in S*/M and S*/M* constructs, respectively, were recovered. Distribution of labelled cells indicated interactions between implanted and host cells. Longer-term in vivo studies will be useful in determining whether implanted cells are sufficient to have a positive effect in repair.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Total hip arthroplasty (THA) has a proven clinical record for providing pain relief and return of function to patients with disabling arthritis. There are many successful options for femoral implant design and fixation. Cemented, polished, tapered femoral implants have been shown to have excellent results in national joint registries and long-term clinical series. These implants are usually 150mm long at their lateral aspect. Due to their length, these implants cannot always be offered to patients due to variations in femoral anatomy. Polished, tapered implants as short as 95mm exist, however their small proximal geometry (neck offset and body size) limit their use to smaller stature patients. There is a group of patients in which a shorter implant with a maintained proximal body size would be advantageous. There are also potential benefits to a shorter implant in standard patient populations such as reduced bone removal due to reduced reaming, favourable loading of the proximal femur, and the ability to revise into good proximal bone stock if required. These factors potentially make a shorter implant an option for all patient populations. The role of implant length in determining the stability of a cemented, polished, tapered femoral implant is not well defined by the literature. Before changes in implant design can be made, a better understanding of the role of each region in determining performance is required. The aim of the thesis was to describe how implant length affects the stability of a cemented, polished, tapered femoral implant. This has been determined through an extensive body of laboratory testing. The major findings are that for a given proximal body size, a reduction in implant length has no effect on the torsional stability of a polished, tapered design, while a small reduction in axial stability should be expected. These findings are important because the literature suggests that torsional stability is the major determinant of long-term clinical performance of a THA system. Furthermore, a polished, tapered design is known to be forgiving of cement-implant interface micromotion due to the favourable wear characteristics. Together these findings suggest that a shorter polished, tapered implant may be well tolerated. The effect of a change in implant length on the geometric characteristics of polished, tapered design were also determined and applied to the mechanical testing. Importantly, interface area does play a role in stability of the system; however it is the distribution of the interface and not the magnitude of the area that defines stability. Taper angle (at least in the range of angles seen in this work) was shown not to be a determinant of axial or torsional stability. A range of implants were tested, comparing variations in length, neck offset and indication (primary versus cement-in-cement revision). At their manufactured length, the 125mm implants were similar to their longer 150mm counterparts suggesting that they may be similarly well tolerated in the clinical environment. However, the slimmer cement-in-cement revision implant was shown to have a poorer mechanical performance, suggesting their use in higher demand patients may be hazardous. An implant length of 125mm has been shown to be quite stable and the results suggest that a further reduction to 100mm may be tolerated. However, further work is required. A shorter implant with maintained proximal body size would be useful for the group of patients who are unable to access the current standard length implants due to variations in femoral anatomy. Extending the findings further, the similar function with potential benefits of a shorter implant make their application to all patients appealing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The desire to solve problems caused by socket prostheses in transfemoral amputees and the acquired success of osseointegration in the dental application has led to the introduction of osseointegration in the orthopedic surgery. Since its first introduction in 1990 in Gothenburg Sweden the osseointegrated (OI) orthopedic fixation has proven several benefits[1]. The surgery consists of two surgical procedures followed by a lengthy rehabilitation program. The rehabilitation program after an OI implant includes a specific training period with a short training prosthesis. Since mechanical loading is considered to be one of the key factors that influence bone mass and the osseointegration of bone-anchored implants, the rehabilitation program will also need to include some form of load bearing exercises (LBE). To date there are two frequently used commercially available human implants. We can find proof in the literature that load bearing exercises are performed by patients with both types of OI implants. We refer to two articles, a first one written by Dr. Aschoff and all and published in 2010 in the Journal of Bone and Joint Surgery.[2] The second one presented by Hagberg et al in 2009 gives a very thorough description of the rehabilitation program of TFA fitted with an OPRA implant. The progression of the load however is determined individually according to the residual skeleton’s quality, pain level and body weight of the participant.[1] Patients are using a classical bathroom weighing scale to control the load on the implant during the course of their rehabilitation. The bathroom scale is an affordable and easy-to-use device but it has some important shortcomings. The scale provides instantaneous feedback to the patient only on the magnitude of the vertical component of the applied force. The forces and moments applied along and around the three axes of the implant are unknown. Although there are different ways to assess the load on the implant for instance through inverse dynamics in a motion analysis laboratory [3-6] this assessment is challenging. A recent proof- of-concept study by Frossard et al (2009) showed that the shortcomings of the weighing scale can be overcome by a portable kinetic system based on a commercial transducer[7].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the first volume to capture the essence of the burgeoning field of cultural studies in a concise and accessible manner. Other books have explored the British and North American traditions, but this is the first guide to the ideas, purposes and controversies that have shaped the subject. The author sheds new light on neglected pioneers and a clear route map through the terrain. He provides lively critical narratives on a dazzling array of key figures including, Arnold, Barrell, Bennett, Carey, Fiske, Foucault, Grossberg, Hall, Hawkes, hooks, Hoggart, Leadbeater, Lissistzky, Malevich, Marx, McLuhan, McRobbie, D Miller, T Miller, Morris, Quiller-Couch, Ross, Shaw, Urry, Williams, Wilson, Wolfe and Woolf. Hartley also examines a host of central themes in the subject including literary and political writing, publishing, civic humanism, political economy and Marxism, sociology, feminism, anthropology and the pedagogy of cultural studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Growth rods are commonly used for the treatment of scoliosis in the immature spine. Many variations have been proposed but breakage of implants is a common problem. Growth rod insertion commonly involves large exposures at initial insertion followed by multiple smaller procedures for lengthening. We present our early experiences using a percutaneous technique of insertion of a new titanium mobile bearing implant (Medtronic Inc). The implant allows some rotatory motion in the middle of the construct thus reducing construct stresses and thus possibly reducing rod breakage risk. Based on this small initial series with 12 months follow-up, percutaneous insertion of growth rods using the new implant is a safe and reliable technique although the infection rate in our sample was of note. This may be related to the titanium wear and inflammation seen in the soft tissues at time of operation and visualised on histology. No implants have required removal due to infection, and all infections were treated with debridement at next lengthening and suppressive antibiotics. Propionibacterium is one of the commonest infections seen with spinal implants and sometimes does not respond to simple antibiotic suppression. The technique allows preservation of the soft tissues until definitive fusion is needed and may lead to a decrease in hospital stay. The implant is low profile and seems to offer advantages over other systems on the market. Further follow up is needed to look at longer term outcomes with this new implant type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents the findings of a study of the psychological variables that discriminate between high and low omitters on a high-stakes achievement test using a short-response format. Data were obtained from a questionnaire administered to a random sample (N = 1,908) of students prior to sitting the 1997 Queensland Core Skills (QCS) Test (N = 29,273). Fourteen psychological variables were measured including test anxiety (four subscales), emotional stability, achievement motivation, self-esteem, academic self-concept, self-estimate of ability, locus of control (three subscales), and approaches to learning (two subscales). The results were analyzed using descriptive discriminant analysis and suggested that the psychological predictors of the propensity to omit short-response items include test-irrelevant thinking and academic self-concept, with sex of candidate being a mediating variable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The overall rate of omission of items for 28,331 17 year old Australian students on a high stakes test of achievement in the common elements or cognitive skills of the senior school curriculum is reported for a subtest in multiple choice format and a subtest in short response format. For the former, the omit rates were minuscule and there was no significant difference by gender or by type of school attended. For the latter, where an item can be 'worth' up to five times that of a single multiple choice item, the omit rates were between 10 and 20 times that for multiple choice and the difference between male and female omit rate was significant as was the difference between students from government and non-government schools. For both formats, females from single sex schools omitted significantly fewer items than did females from co-educational schools. Some possible explanations of omit behaviour are alluded to.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate staff perceptions about working environment, efficiency and the clinical safety of a cardiovascular intervention short stay unit (SSU) during the first year of operation. Design Postal questionnaire. Setting Cardiac catheterisation laboratory (CCL), coronary care unit (CCU), general cardiology ward (GCW) and the short stay unit (SSU) of a tertiary referral hospital situated in the mid coastal region of NSW. Subjects Cardiologists (including visiting medical officers [VMO]), cardiology fellows, cardiology advanced trainees and nurses. Results Responses on the working environment of the SSU and the discharge process were statistically significant. A substantial proportion of both nurses and doctors had concerns about patient safety, even though no adverse events were formally recorded in the database. Conclusions Though the participants of the survey agree on the efficiency of the SSU in providing beds to the hospital, they disagree on aspects that are important in the functioning of the SSU, including the working environment, patient selection and clinical safety. The results highlight potential issues that could be improved or addressed and are relevant to the rollout of SSUs across NSW.