238 resultados para SOFT CONTACT LAMINATION
em Queensland University of Technology - ePrints Archive
Resumo:
Objectives. To evaluate the performance of the dynamic-area high-speed videokeratoscopy technique in the assessment of tear film surface quality with and without the presence of soft contact lenses on eye. Methods. Retrospective data from a tear film study using basic high-speed videokeratoscopy, captured at 25 frames per second, (Kopf et al., 2008, J Optom) were used. Eleven subjects had tear film analysis conducted in the morning, midday and evening on the first and seventh day of one week of no lens wear. Five of the eleven subjects then completed an extra week of hydrogel lens wear followed by a week of silicone hydrogel lens wear. Analysis was performed on a 6 second period of the inter-blink recording. The dynamic-area high-speed videokeratoscopy technique uses the maximum available area of Placido ring pattern reflected from the tear interface and eliminates regions of disturbance due to shadows from the eyelashes. A value of tear film surface quality was derived using image rocessing techniques, based on the quality of the reflected ring pattern orientation. Results. The group mean tear film surface quality and the standard deviations for each of the conditions (bare eye, hydrogel lens, and silicone hydrogel lens) showed a much lower coefficient of variation than previous methods (average reduction of about 92%). Bare eye measurements from the right and left eyes of eleven individuals showed high correlation values (Pearson’s correlation r = 0.73, p < 0.05). Repeated measures ANOVA across the 6 second period of measurement in the normal inter-blink period for the bare eye condition showed no statistically significant changes. However, across the 6 second inter-blink period with both contact lenses, statistically significant changes were observed (p < 0.001) for both types of contact lens material. Overall, wearing hydrogel and silicone hydrogel lenses caused the tear film surface quality to worsen compared with the bare eye condition (repeated measures ANOVA, p < 0.0001 for both hydrogel and silicone hydrogel). Conclusions. The results suggest that the dynamic-area method of high-speed videokeratoscopy was able to distinguish and quantify the subtle, but systematic worsening of tear film surface quality in the inter-blink interval in contact lens wear. It was also able to clearly show a difference between bare eye and contact lens wearing conditions.
Resumo:
This study was designed to derive central and peripheral oxygen transmissibility (Dk/t) thresholds for soft contact lenses to avoid hypoxia-induced corneal swelling (increased corneal thickness) during open eye wear. Central and peripheral corneal thicknesses were measured in a masked and randomized fashion for the left eye of each of seven subjects before and after 3 h of afternoon wear of five conventional hydrogel and silicone hydrogel contact lens types offering a range of Dk/t from 2.4 units to 115.3 units. Curve fitting for plots of change in corneal thickness versus central and peripheral Dk/t found threshold values of 19.8 and 32.6 units to avoid corneal swelling during open eye contact lens wear for a typical wearer. Although some conventional hydrogel soft lenses are able to achieve this criterion for either central or peripheral lens areas (depending on lens power), in general, no conventional hydrogel soft lenses meet both the central and peripheral thresholds. Silicone hydrogel contact lenses typically meet both the central and peripheral thresholds and use of these lenses therefore avoids swelling in all regions of the cornea. ' 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 92B: 361–365, 2010
Resumo:
Purpose: To investigate the influence of soft contact lenses on regional variations in corneal thickness and shape while taking account of natural diurnal variations in these corneal parameters. Methods: Twelve young, healthy subjects wore 4 different types of soft contact lenses on 4 different days. The lenses were of two different materials (silicone hydrogel, hydrogel), designs (spherical, toric) and powers (–3.00, –7.00 D). Corneal thickness and topography measurements were taken before and after 8 hours of lens wear and on two days without lens wear, using the Pentacam HR system. Results: The hydrogel toric contact lens caused the greatest level of corneal thickening in the central (20.3 ± 10.0 microns) as well as peripheral cornea (24.1 ± 9.1 microns) (p < 0.001) with an obvious regional swelling of the cornea beneath the stabilizing zones. The anterior corneal surface generally showed slight flattening. All contact lenses resulted in central posterior corneal steepening and this was weakly correlated with central corneal swelling (p = 0.03) and peripheral corneal swelling (p = 0.01). Conclusions: There was an obvious regional corneal swelling apparent after wear of the hydrogel soft toric lenses, due to the location of the thicker stabilization zones of the toric lenses. However with the exception of the hydrogel toric lens, the magnitude of corneal swelling induced by the contact lenses over the 8 hours of wear was less than the natural diurnal thinning of the cornea over this same period.
Resumo:
To evaluate the effect of soft contact lens type on the in vivo tear film surface quality (TFSQ) on daily disposable lenses and to establish whether two recently developed techniques for noninvasive measurement of TFSQ can distinguish between different contact lens types.
Resumo:
Objectives: To measure tear film surface quality (TFSQ) using dynamic high-speed videokeratoscopy during short-term (8 hours) use of rigid and soft contact lenses. Methods: A group of fourteen subjects wore 3 different types of contact lenses on 3 different non-consecutive days (order randomized) in one eye only. Subjects were screened to exclude those with dry eye. The lenses included a PMMA hard, an RGP (Boston XO) and a soft silicone hydrogel lens. Three 30 second long high speed videokeratoscopy recordings were taken with contact lenses in-situ, in the morning and again after 8 hours of contact lens wear, both in normal and suppressed blinking conditions. Recordings were also made on a baseline day with no contact lens wear. Results: The presence of a contact lens in the eye had a significant effect on the mean TFSQ in both natural and suppressed blinking conditions (p=0.001 and p=0.01 respectively, repeated measures ANOVA). TFSQ was worse with all the lenses compared to no lens in the eye (in the afternoon during both normal and suppressed blinking conditions (all p<0.05). In natural blinking conditions, the mean TFSQ for the PMMA and RGP lenses was significantly worse than the baseline day (no lens) for both morning and afternoon measures (p<0.05). Conclusions: This study shows that both rigid and soft contact lenses adversely affect the TFSQ in both natural and suppressed blinking conditions. No significant differences were found between the lens types and materials. Keywords: Tear film surface quality, rigid contact lens, soft contact lens, dynamic high-speed videokeratoscopy
Resumo:
Purpose. To evaluate the use of optical coherence tomography (OCT) to assess the effect of different soft contact lenses on corneoscleral morphology. Methods. Ten subjects had anterior segment OCT B-scans taken in the morning and again after six hours of soft contact lens wear. For each subject, three different contact lenses were used in the right eye on non-consecutive days, including a hydrogel sphere, a silicone hydrogel sphere and a silicone hydrogel toric. After image registration and layer segmentation, analyses were performed of the first hyper-reflective layer (HRL), the epithelial basement membrane (EBL) and the epithelial thickness (HRL to EBL). A root mean square difference (RMSD) of the layer profiles and the thickness change between the morning and afternoon measurements, was used to assess the effect of the contact lens on the corneoscleral morphology. Results. The soft contact lenses had a statistically significant effect on the morphology of the anterior segment layers (p <0.001). The average amounts of change for the three lenses (average RMSD values) for the corneal region were lower (3.93±1.95 µm for the HRL and 4.02±2.14 µm for the EBL) than those measured in the limbal/scleral region (11.24±6.21 µm for the HRL and 12.61±6.42 µm for the EBL). Similarly, averaged across the three lenses, the RMSD in epithelial thickness was lower in the cornea (2.84±0.84 µm) than the limbal/scleral (5.47±1.71 µm) region. Post-hoc analysis showed that ocular surface changes were significantly smaller with the silicone hydrogel sphere lens than both the silicone hydrogel toric (p<0.005) and hydrogel sphere (p<0.02) for the combined HRL and EBL data. Conclusions. In this preliminary study, we have shown that soft contact lenses can produce small but significant changes in the morphology of the limbal/scleral region and that OCT technology is useful in assessing these changes. The clinical significance of these changes is yet to be determined.
Resumo:
Whether the first daily disposable soft contact lens to enter the market in 1994 was the Premier lens (Award Technology, Scotland, UK; subsequently purchased by Bausch & Lomb, Rochester New York, USA) or the 1-Day Acuvue lens (Johnson and Johnson Vision Care, Jacksonville, Florida, USA) has long been a matter of bitter dispute1 but whatever the answer, this year marks the 20th anniversary of the launch of this modality of lens wear...
Resumo:
Purpose To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Conclusions Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result didn’t change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.
Resumo:
There have been significant improvements in toric soft contact lens design over the past decade. Data from our international contact lens prescribing survey were mined to assess recent trends in toric soft contact lens fitting. This survey was conducted by sending up to 1000 survey forms to contact lens fitters in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA each year between 2000 and 2009. Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the forms and to return them to us for analysis. The data revealed a gradual increase in the extent of toric soft lens fitting this century. Excluding Japan – which had a consistently low rate of soft toric lens fitting over the survey period – soft toric lenses now represent over 35% of all soft lenses prescribed; it can be assumed that, on average (and again excluding Japan), all cases of astigmatism 0.75 D or less remains uncorrected among contact lens wearers. Toric lenses are fitted more to those who are older, full-time wearers and reusable lens wearers, and less to those wearing silicone hydrogel and extended wear lenses.
Resumo:
Cosmetically tinted soft contact lenses are an attractive option for contact lens wearers. Data that we have gathered from annual contact lens fitting surveys demonstrate that those wearing tinted lenses are more likely to be female (4.6% of all soft lenses fitted vs. 1.6% for males; p < 0.0001) and younger (27 11 years vs. 33 13 years for those wearing non-tinted lenses; p < 0.0001). Tinted lenses tend to be worn more on a part-time basis and are replaced less frequently than non-tinted lenses. The decline in fitting tinted lenses over the past 12 years may be due to (a) the current limited availability of tinted lenses in silicone hydrogel materials and daily disposable replacement frequencies, which together represent a significant majority (78%) of new soft lenses fits today, (b) growing concerns among lens wearers and practitioners relating to the risks of complications associated with the wearing of tinted lenses, and (c) reduced promotion of such lenses by the contact lens industry.
Resumo:
The ageing population highlights the need to provide effective optical solutions for presbyopic contact lens wearers. However, data gathered from annual contact lens fitting surveys demonstrate that fewer than 40% of contact lens wearers over 45 years of age (virtually all of whom can be presumed to suffer a partial or complete loss of accommodation) are prescribed a presbyopic correction. Furthermore, monovision is prescribed as frequently as multifocal lenses. These observations suggest that an optimal solution to the contact lens correction of presbyopia remains elusive.
Resumo:
Hydrogel polymers are used for the manufacture of soft (or disposable) contact lenses worldwide today, but have a tendency to dehydrate on the eye. In vitro methods that can probe the potential for a given hydrogel polymer to dehydrate in vivo are much sought after. Nuclear magnetic resonance (NMR) has been shown to be effective in characterising water mobility and binding in similar systems (Barbieri, Quaglia et al., 1998, Larsen, Huff et al., 1990, Peschier, Bouwstra et al., 1993), predominantly through measurement of the spin-lattice relaxation time (T1), the spinspin relaxation time (T2) and the water diffusion coefficient (D). The aim of this work was to use NMR to quantify the molecular behaviour of water in a series of commercially available contact lens hydrogels, and relate these measurements to the binding and mobility of the water, and ultimately the potential for the hydrogel to dehydrate. As a preliminary study, in vitro evaporation rates were measured for a set of commercial contact lens hydrogels. Following this, comprehensive measurement of the temperature and water content dependencies of T1, T2 and D was performed for a series of commercial hydrogels that spanned the spectrum of equilibrium water content (EWC) and common compositions of contact lenses that are manufactured today. To quantify material differences, the data were then modelled based on theory that had been used for similar systems in the literature (Walker, Balmer et al., 1989, Hills, Takacs et al., 1989). The differences were related to differences in water binding and mobility. The evaporative results suggested that the EWC of the material was important in determining a material's potential to dehydrate in this way. Similarly, the NMR water self-diffusion coefficient was also found to be largely (if not wholly) determined by the WC. A specific binding model confirmed that the we was the dominant factor in determining the diffusive behaviour, but also suggested that subtle differences existed between the materials used, based on their equilibrium we (EWC). However, an alternative modified free volume model suggested that only the current water content of the material was important in determining the diffusive behaviour, and not the equilibrium water content. It was shown that T2 relaxation was dominated by chemical exchange between water and exchangeable polymer protons for materials that contained exchangeable polymer protons. The data was analysed using a proton exchange model, and the results were again reasonably correlated with EWC. Specifically, it was found that the average water mobility increased with increasing EWe approaching that of free water. The T1 relaxation was also shown to be reasonably well described by the same model. The main conclusion that can be drawn from this work is that the hydrogel EWe is an important parameter, which largely determines the behaviour of water in the gel. Higher EWe results in a hydrogel with water that behaves more like bulk water on average, or is less strongly 'bound' on average, compared with a lower EWe material. Based on the set of materials used, significant differences due to composition (for materials of the same or similar water content) could not be found. Similar studies could be used in the future to highlight hydrogels that deviate significantly from this 'average' behaviour, and may therefore have the least/greatest potential to dehydrate on the eye.
Resumo:
Purpose: The aim was to construct and advise on the use of a cost-per-wear model based on contact lens replacement frequency, to form an equitable basis for cost comparison. ---------- Methods: The annual cost of professional fees, contact lenses and solutions when wearing daily, two-weekly and monthly replacement contact lenses is determined in the context of the Australian market for spherical, toric and multifocal prescription types. This annual cost is divided by the number of times lenses are worn per year, resulting in a ‘cost-per-wear’. The model is presented graphically as the cost-per-wear versus the number of times lenses are worn each week for daily replacement and reusable (two-weekly and monthly replacement) lenses.---------- Results: The cost-per-wear for two-weekly and monthly replacement spherical lenses is almost identical but decreases with increasing frequency of wear. The cost-per-wear of daily replacement spherical lenses is lower than for reusable spherical lenses, when worn from one to four days per week but higher when worn six or seven days per week. The point at which the cost-per-wear is virtually the same for all three spherical lens replacement frequencies (approximately AUD$3.00) is five days of lens wear per week. A similar but upwardly displaced (higher cost) pattern is observed for toric lenses, with the cross-over point occurring between three and four days of wear per week (AUD$4.80). Multifocal lenses have the highest price, with cross-over points for daily versus two-weekly replacement lenses at between four and five days of wear per week (AUD$5.00) and for daily versus monthly replacement lenses at three days per week (AUD$5.50).---------- Conclusions: This cost-per-wear model can be used to assist practitioners and patients in making an informed decision in relation to the cost of contact lens wear as one of many considerations that must be taken into account when deciding on the most suitable lens replacement modality.
Twenty first century trends in silicone hydrogel contact lens fitting : an international perspective
Resumo:
Silicone hydrogel contact lenses were introduced into the market in 1999. To assess prescribing trends of this lens type since then, up to 1000 survey forms were sent to contact lens fitters in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA each year between 2000 and 2008. Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Analysis of returned forms revealed a rapid increase in the prescribing of silicone hydrogel lenses over the survey period. In 2008, silicone hydrogel lenses represented 36% of all soft lenses prescribed. The categorization of the majority of lenses prescribed as ‘refits’ is primarily attributed to the mass conversion of lens wearers from hydrogel to silicone hydrogel lenses. Silicone hydrogels may soon represent the majority of soft contact lenses prescribed.