8 resultados para RADIOIMMUNOASSAY

em Queensland University of Technology - ePrints Archive


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studies have examined the associations between cancers and circulating 25-hydroxyvitamin D [25(OH)D], but little is known about the impact of different laboratory practices on 25(OH)D concentrations. We examined the potential impact of delayed blood centrifuging, choice of collection tube, and type of assay on 25(OH)D concentrations. Blood samples from 20 healthy volunteers underwent alternative laboratory procedures: four centrifuging times (2, 24, 72, and 96 h after blood draw); three types of collection tubes (red top serum tube, two different plasma anticoagulant tubes containing heparin or EDTA); and two types of assays (DiaSorin radioimmunoassay [RIA] and chemiluminescence immunoassay [CLIA/LIAISON®]). Log-transformed 25(OH)D concentrations were analyzed using the generalized estimating equations (GEE) linear regression models. We found no difference in 25(OH)D concentrations by centrifuging times or type of assay. There was some indication of a difference in 25(OH)D concentrations by tube type in CLIA/LIAISON®-assayed samples, with concentrations in heparinized plasma (geometric mean, 16.1 ng ml−1) higher than those in serum (geometric mean, 15.3 ng ml−1) (p = 0.01), but the difference was significant only after substantial centrifuging delays (96 h). Our study suggests no necessity for requiring immediate processing of blood samples after collection or for the choice of a tube type or assay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To determine whether there are clinical and public health dilemmas resulting from the reproducibility of routine vitamin D assays. Methods: Blinded agreement studies were conducted in eight clinical laboratories using two commonly used assays to measure serum 25-hydroxyvitamin D (25(OH)D) levels in Australasia and Canada (DiaSorin Radioimmunoassay (RIA) and DiaSorin LIAISON® one). Results: Only one laboratory measured 25(OH)D with excellent precision. Replicate 25(OH)D measurements varied by up to 97% and 15% of paired results differed by more than 50%. Thirteen percent of subjects received one result indicating insufficiency [25-50 nmol/l] and another suggesting adequacy [>50 nmol/l]). Agreement ranged from poor to excellent for laboratories using the manual RIA, while the precision of the semi-automated Liaison® system was consistently poor. Conclusions: Recent interest in the relevance of vitamin D to human health has increased demand for 25(OH)D testing and associated costs. Our results suggest clinicians and public health authorities are making decisions about treatment or changes to public health policy based on imprecise data. Clinicians, researchers and policy makers should be made aware of the imprecision of current 25(OH)D testing so that they exercise caution when using these assays for clinical practice, and when interpreting the findings of epidemiological studies based on vitamin D levels measured using these assays. Development of a rapid, reproducible, accurate and robust assay should be a priority due to interest in populationbased screening programs and research to inform public health policy about the amount of sun exposure required for human health. In the interim, 25(OH)D results should routinely include a statement of measurement uncertainty.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study of biologically active peptides is critical to the understanding of physiological pathways, especially those involved in the development of disease. Historically, the measurement of biologically active endogenous peptides has been undertaken by radioimmunoassay, a highly sensitive and robust technique that permits the detection of physiological concentrations in different biofluid and tissue extracts. Over recent years, a range of mass spectrometric approaches have been applied to peptide quantification with limited degrees of success. Neuropeptide Y (NPY), peptide YY (PYY), and pancreatic polypeptide (PP) belong to the NPY family exhibiting regulatory effects on appetite and feeding behavior. The physiological significance of these peptides depends on their molecular forms and in vivo concentrations systemically and at local sites within tissues. In this report, we describe an approach for quantification of individual peptides within mixtures using high-performance liquid chromatography electrospray ionization tandem mass spectrometry analysis of the NPY family peptides. Aspects of quantification including sample preparation, the use of matrix-matched calibration curves, and internal standards will be discussed. This method for the simultaneous determination of NPY, PYY, and PP was accurate and reproducible but lacks the sensitivity required for measurement of their endogenous concentration in plasma. The advantages of mass spectrometric quantification will be discussed alongside the current obstacles and challenges. © 2012 Wiley Periodicals, Inc. Biopolymers (Pept Sci) 98: 357–366, 2012.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Little is known about the relation between vitamin D status in early life and neurodevelopment outcomes. Objective This study was designed to examine the association of cord blood 25-hydroxyvitamin D [25(OH)D] at birth with neurocognitive development in toddlers. Methods As part of the China-Anhui Birth Cohort Study, 363 mother-infant pairs with completed data were selected. Concentrations of 25(OH)D in cord blood were measured by radioimmunoassay. Mental development index (MDI) and psychomotor development index (PDI) in toddlers were assessed at age 16–18 mo by using the Bayley Scales of Infant Development. The data on maternal sociodemographic characteristics and other confounding factors were also prospectively collected. Results Toddlers in the lowest quintile of cord blood 25(OH)D exhibited a deficit of 7.60 (95% CI: −12.4, −2.82; P = 0.002) and 8.04 (95% CI: −12.9, −3.11; P = 0.001) points in the MDI and PDI scores, respectively, compared with the reference category. Unexpectedly, toddlers in the highest quintile of cord blood 25(OH)D also had a significant deficit of 12.3 (95% CI: −17.9, −6.67; P < 0.001) points in PDI scores compared with the reference category. Conclusions This prospective study suggested that there was an inverted-U–shaped relation between neonatal vitamin D status and neurocognitive development in toddlers. Additional studies on the optimal 25(OH)D concentrations in early life are needed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Serum immunoreactive cationic trypsinogen levels were determined in 99 control subjects and 381 cystic fibrosis (CF) patients. To evaluate the status of the exocrine pancreas all CF patients had previously undergone fecal fat balance studies and/or pancreatic stimulation tests. Three hundred fourteen CF patients had fat malabsorption and/or had inadequate pancreatic enzyme secretion (pancreatic insufficiency) requiring oral pancreatic enzyme supplements with meals. Sixty-seven CF patients did not have fat malabsorption and/or had adequate enzyme secretion (pancreatic sufficiency) and were not receiving pancreatic enzyme supplements with meals. Mean serum trypsinogen in 99 control subjects was 31.4 ± 14.8 /µg/hter (± 2 SD) and levels did not vary with age or sex. In CF infants (< 2 yr) with pancreatic insufficiency, mean serum trypsinogen was significantly above the non-CF values (p < 0.001). Ninety-one percent of the CF infants had elevated levels. Serum trypsinogen values in the pancreatic insuffi ient group declined steeply up to 5 years, reaching subnormal values by age 6. An equation was developed which described these age-related changes very accurately. Only six CF patients with pancreatic insufficiency had serum trypsinogen levels above the 95% confidence limits of this equation. In contrast, there was no age related decline in serum trypsinogen among the CF group with pancreatic sufficiency. Under 7 yr, serum trypsinogen failed to distinguish the two groups. In those over 7 yr of age, however, serum trypsinogen was significantly higher than the CF group with pancreatic insufficiency (p < 0.001), and 93% had values within or above the control range. In conclusion, serum trypsinogen appears to be a useful screening test for CF in infancy. Between 2 and 7 yr of age this test is of little diagnostic value. After 7 yr of age, serum trypsinogen can reliably distinguish between CF patients with and without pancreatic insufficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Indirect and qualitative tests of pancreatic function are commonly used to screen patients with cystic fibrosis for pancreatic insufficiency. In an attempt to develop a more quantitative assessment, we compared the usefulness of measuring serum pancreatic lipase using a newly developed enzyme-linked immunosorbent immunoassay with that of cationic trypsinogen using a radioimmunoassay in the assessment of exocrine pancreatic function in patients with cystic fibrosis. Previously, we have shown neither lipase nor trypsinogen to be of use in assessing pancreatic function prior to 5 years of age because the majority of patients with cystic fibrosis in early infancy have elevated serum levels regardless of pancreatic function. Therefore, we studied 77 patients with cystic fibrosis older than 5 years of age, 41 with steatorrhea and 36 without steatorrhea. In addition, 28 of 77 patients consented to undergo a quantitative pancreatic stimulation test. There was a significant difference between the steatorrheic and nonsteatorrheic patients with the steatorrheic group having lower lipase and trypsinogen values than the nonsteatorrheic group (P < .001). Sensitivities and specificities in detecting steatorrhea were 95% and 86%, respectively, for lipase and 93% and 92%, respectively, for trypsinogen. No correlations were found between the serum levels of lipase and trypsinogen and their respective duodenal concentrations because of abnormally high serum levels of both enzymes found in some nonsteatorrheic patients. We conclude from this study that both serum lipase and trypsinogen levels accurately detect steatorrhea in patients with cystic fibrosis who are older than 5 years but are imprecise indicators of specific pancreatic exocrine function above the level needed for normal fat absorption.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Serum immunoreactive pancreatic lipase and cationic trypsinogen are elevated in young infants with cystic fibrosis (CF) and may be useful neonatal screening tests for CF. We compared lipase measured by a recently developed ELISA immunoassay with trypsinogen measured by radioimmunoassay in 70 children (ages 0.1 to 9.9 years) with CF who had various degrees of pancreatic dysfunction and in 79 similarly aged children without CF (controls). In the control children, lipase activity increased with advancing age, whereas trypsinogen showed no age-related trend. Lipase and trypsinogen were significantly elevated in the infants with CF who were younger than 1 year, irrespective of pancreatic function (trypsinogen, P<0.001; lipase, P<0.05). Sensitivities in detecting CF were 76% and 90% for lipase and trypsinogen, respectively. After the first year of life, lipase and trypsinogen values declined toward normal, the rate of decline of lipase being greater than that of trypsinogen; 67% of lipase values were within or below the normal range by 3 years, whereas 67% of trypsinogen values continued to be elevated. We conclude that trypsinogen is an excellent screening test for CF in young infants regardless of pancreatic function, and that the addition of a serum pancreatic lipase determination does not improve the accuracy of trypsinogen as a screening test for cystic fibrosis.