244 resultados para Pooled testing
em Queensland University of Technology - ePrints Archive
Resumo:
Bisphenol A (BPA or 4,4’-(propane-2,2-diyl)diphenol) is a chemical intermediate in the production of polycarbonate and epoxy resins, and used in a wide range of applications. BPA has attracted significant attention in the past decade due to its frequency of detection in human populations worldwide, demonstrated animal toxicity and potential impact on human health, particularly during critical periods of development. The aim of this study was to perform a preliminary assessment of age-related trends in urinary concentration and to estimate daily excretion of BPA in Australian children (aged (>0 – <5 years) and adults (≥15 – <75 years). This was achieved using 79 samples pooled by age and gender, created from 868 individual samples of convenience collected as part of routine, community-based pathology testing. Total BPA was analyzed using online-SPE-LC-MS/MS and detected in all samples with a range of 0.65 – 265 ng/ml. No significant differences were observed between males and females. A urine flow model was constructed from published values and used to provide an estimate of daily excretion per unit bodyweight for each pooled sample. The daily excretion estimates ranged from 26.2 – 18200 ng/kg-d for children; and 20.1 – 165 ng/kg-d for adults. Urinary concentrations and estimated excretion rates were inversely associated with age, and estimated daily excretion rates in infants and young children were significantly higher than in adults (geometric mean: 107 and 47.0 ng/kg-d, respectively). Higher excretion of BPA in children may be explained by their higher food consumption relative to body weight compared to adults and adolescents, and may also reflect alternative exposure pathways and sources. Keywords: bisphenol A, biomonitoring, children, urine flow, Australia
Resumo:
Background: The irreversible epidermal growth factor receptor (EGFR) inhibitors have demonstrated efficacy in NSCLC patients with activating EGFR mutations, but it is unknown if they are superior to the reversible inhibitors. Dacomitinib is an oral, small-molecule irreversible inhibitor of all enzymatically active HER family tyrosine kinases. Methods: The ARCHER 1009 (NCT01360554) and A7471028 (NCT00769067) studies randomized patients with locally advanced/metastatic NSCLC following progression with one or two prior chemotherapy regimens to dacomitinib or erlotinib. EGFR mutation testing was performed centrally on archived tumor samples. We pooled patients with exon 19 deletion and L858R EGFR mutations from both studies to compare the efficacy of dacomitinib to erlotinib. Results: One hundred twenty-one patients with any EGFR mutation were enrolled; 101 had activating mutations in exon 19 or 21. For patients with exon19/21 mutations, the median progression-free survival was 14.6 months [95% confidence interval (CI) 9.0–18.2] with dacomitinib and 9.6 months (95% CI 7.4–12.7) with erlotinib [unstratified hazard ratio (HR) 0.717 (95% CI 0.458–1.124), two-sided log-rank, P = 0.146]. The median survival was 26.6 months (95% CI 21.6–41.5) with dacomitinib versus 23.2 months (95% CI 16.0–31.8) with erlotinib [unstratified HR 0.737 (95% CI 0.431–1.259), two-sided log-rank, P = 0.265]. Dacomitinib was associated with a higher incidence of diarrhea and mucositis in both studies compared with erlotinib. Conclusions: Dacomitinib is an active agent with comparable efficacy to erlotinib in the EGFR mutated patients. The subgroup with exon 19 deletion had favorable outcomes with dacomitinib. An ongoing phase III study will compare dacomitinib to gefitinib in first-line therapy of patients with NSCLC harboring common activating EGFR mutations (ARCHER 1050; NCT01774721). Clinical trials number: ARCHER 1009 (NCT01360554) and A7471028 (NCT00769067).
Resumo:
Process modeling can be regarded as the currently most popular form of conceptual modeling. Research evidence illustrates how process modeling is applied across the different information system life cycle phases for a range of different applications, such as configuration of Enterprise Systems, workflow management, or software development. However, a detailed discussion of critical factors of the quality of process models is still missing. This paper proposes a framework consisting of six quality factors, which is derived from a comprehensive literature review. It then presents in a case study, a utility provider, who had designed various business process models for the selection of an Enterprise System. The paper summarizes potential means of conducting a successful process modeling initiative and evaluates the described modeling approach within the Guidelines of Modeling (GoM) framework. An outlook shows the potential lessons learnt, and concludes with insights to the next phases of this study.
Resumo:
The behavioral theory of “entrepreneurial bricolage” attempts to understand what entrepreneurs do when faced with resource constraints. Most research about bricolage, defined as “making do by applying combinations of the resources at hand to new problems and opportunities” (Baker & Nelson 2005: 333), has been qualitative and inductive (Garud & Karnoe, 2003). Although this has created a small body of rich descriptions and interesting insights, little deductive theory has been developed and the relationship between bricolage and firm performance has not been systematically tested. In particular, prior research has suggested bricolage can have both beneficial and harmful effects. Ciborra’s (1996) study of Olivetti suggested that bricolage helped Olivetti to adapt, but simultaneously constrained firm effectiveness. Baker & Nelson (2005) suggested that bricolage may be harmful at very high levels, but more helpful if used judiciously. Other research suggests that firm innovativeness may play an important role in shaping the outcomes of bricolage (Anderson 2008). In this paper, we theorize and provide preliminary test of the bricolage-performance relationship and how it is affected by firm innovativeness.
Resumo:
“Hardware in the Loop” (HIL) testing is widely used in the automotive industry. The sophisticated electronic control units used for vehicle control are usually tested and evaluated using HIL-simulations. The HIL increases the degree of realistic testing of any system. Moreover, it helps in designing the structure and control of the system under test so that it works effectively in the situations that will be encountered in the system. Due to the size and the complexity of interaction within a power network, most research is based on pure simulation. To validate the performance of physical generator or protection system, most testing is constrained to very simple power network. This research, however, examines a method to test power system hardware within a complex virtual environment using the concept of the HIL. The HIL testing for electronic control units and power systems protection device can be easily performed at signal level. But performance of power systems equipments, such as distributed generation systems can not be evaluated at signal level using HIL testing. The HIL testing for power systems equipments is termed here as ‘Power Network in the Loop’ (PNIL). PNIL testing can only be performed at power level and requires a power amplifier that can amplify the simulation signal to the power level. A power network is divided in two parts. One part represents the Power Network Under Test (PNUT) and the other part represents the rest of the complex network. The complex network is simulated in real time simulator (RTS) while the PNUT is connected to the Voltage Source Converter (VSC) based power amplifier. Two way interaction between the simulator and amplifier is performed using analog to digital (A/D) and digital to analog (D/A) converters. The power amplifier amplifies the current or voltage signal of simulator to the power level and establishes the power level interaction between RTS and PNUT. In the first part of this thesis, design and control of a VSC based power amplifier that can amplify a broadband voltage signal is presented. A new Hybrid Discontinuous Control method is proposed for the amplifier. This amplifier can be used for several power systems applications. In the first part of the thesis, use of this amplifier in DSTATCOM and UPS applications are presented. In the later part of this thesis the solution of network in the loop testing with the help of this amplifier is reported. The experimental setup for PNIL testing is built in the laboratory of Queensland University of Technology and the feasibility of PNIL testing has been evaluated using the experimental studies. In the last section of this thesis a universal load with power regenerative capability is designed. This universal load is used to test the DG system using PNIL concepts. This thesis is composed of published/submitted papers that form the chapters in this dissertation. Each paper has been published or submitted during the period of candidature. Chapter 1 integrates all the papers to provide a coherent view of wide bandwidth switching amplifier and its used in different power systems applications specially for the solution of power systems testing using PNIL.
Resumo:
Aim: In the current climate of medical education, there is an ever-increasing demand for and emphasis on simulation as both a teaching and training tool. The objective of our study was to compare the realism and practicality of a number of artificial blood products that could be used for high-fidelity simulation. Method: A literature and internet search was performed and 15 artificial blood products were identified from a variety of sources. One product was excluded due to its potential toxicity risks. Five observers, blinded to the products, performed two assessments on each product using an evaluation tool with 14 predefined criteria including color, consistency, clotting, and staining potential to manikin skin and clothing. Each criterion was rated using a five-point Likert scale. The products were left for 24 hours, both refrigerated and at room temperature, and then reassessed. Statistical analysis was performed to identify the most suitable products, and both inter- and intra-rater variability were examined. Results: Three products scored consistently well with all five assessors, with one product in particular scoring well in almost every criterion. This highest-rated product had a mean rating of 3.6 of 5.0 (95% posterior Interval 3.4-3.7). Inter-rater variability was minor with average ratings varying from 3.0 to 3.4 between the highest and lowest scorer. Intrarater variability was negligible with good agreement between first and second rating as per weighted kappa scores (K = 0.67). Conclusion: The most realistic and practical form of artificial blood identified was a commercial product called KD151 Flowing Blood Syrup. It was found to be not only realistic in appearance but practical in terms of storage and stain removal.