4 resultados para Pädagogik, Volkshochschule Jena, Jugendbewegung, Carl Heinrich Becker, Pädagogische Akademie Halle, Kreisauer Kreis, Religiöser Sozialismus

em Queensland University of Technology - ePrints Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article introduces a model for group facilitation in the humanities based on Carl Rogers’s model for group psychotherapy. Certain aspects of Rogers’s reflective learning strategies are re-appraised and principles, specific only to psychotherapy, are introduced. Five of Rogers’s axioms are applied to the tutorial discussion model: a non-directive approach, climate-setting, facilitation, reflective listening and positive regard. The model, which has been trialed in tutorials at The University of Queensland, encourages self-direction, active learning and critical thinking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lung cancer is the most important cause of cancer-related mortality. Resectability and eligibility for treatment with adjuvant chemotherapy is determined by staging according to the TNM classification. Other determinants of tumour behaviour that predict disease outcome, such as molecular markers, may improve decision-making. Activation of the gene encoding human telomerase reverse transcriptase (hTERT) is implicated in the pathogenesis of lung cancer, and consequently detection of hTERT mRNA might have prognostic value for patients with early stage lung cancer. A cohort of patients who underwent a complete resection for early stage lung cancer was recruited as part of the European Early Lung Cancer (EUELC) project. In 166 patients expression of hTERT mRNA was determined in tumour tissue by quantitative real-time RT-PCR and related to that of a house-keeping gene (PBGD). Of a subgroup of 130 patients tumour-distant normal tissue was additionally available for hTERT mRNA analysis. The correlation between hTERT levels of surgical samples and disease-free survival was determined using a Fine and Gray hazard model. Although hTERT mRNA positivity in tumour tissue was significantly associated with clinical stage (Fisher's exact test p=0.016), neither hTERT mRNA detectability nor hTERT mRNA levels in tumour tissue were associated with clinical outcome. Conversely, hTERT positivity in adjacent normal samples was associated with progressive disease, 28% of patients with progressive disease versus 7.5% of disease-free patients had detectable hTERT mRNA in normal tissue [adjusted HR: 3.60 (1.64-7.94), p=0.0015]. hTERT mRNA level in tumour tissue has no prognostic value for patients with early stage lung cancer. However, detection of hTERT mRNA expression in tumour-distant normal lung tissue may indicate an increased risk of progressive disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess intrasessional and intersessional repeatability of two commercial partial coherence interferometry instruments for measuring peripheral eye lengths and to investigate the agreement between the two instruments. Methods: Central and peripheral eye lengths were determined with the IOLMaster (Carl-Zeiss Meditec AG, Jena, Germany) and the Lenstar (Haag Streit, Bern, Switzerland) in seven adults. Measurements were performed out to 35° and 30° from fixation for horizontal and vertical visual fields, respectively, in 5° intervals. An external fixation target at optical infinity was used. At least four measurements were taken at each location for each instrument, and measurements were taken at two sessions. Results: The mean intrasessional SDs for the IOLMaster along both the horizontal and vertical visual fields were 0.04 ± 0.04 mm; corresponding results for the Lenstar were 0.02 ± 0.02 mm along both fields. The intersessional SDs for the IOLMaster for the horizontal and vertical visual fields were ±0.11 and ±0.08 mm, respectively; corresponding limits for the Lenstar were ±0.05 and ±0.04 mm. The intrasessional and intersessional variability increased away from fixation. The mean differences between the two instruments were 0.01 ± 0.07 mm and 0.02 ± 0.07 mm in the horizontal and vertical visual fields, but the lengths with the Lenstar became greater than those with the IOLMaster as axial length increased (rate of approximately 0.016 mm/mm). Conclusions: Both the IOLMaster and the Lenstar demonstrated good intrasessional and intersessional repeatability for peripheral eye length measurements, with the Lenstar showing better repeatability. The Lenstar would be expected to give a slightly greater range of eye lengths than the IOLMaster across the visual field.