479 resultados para National Joint Registry
em Queensland University of Technology - ePrints Archive
Resumo:
Mortality following hip arthroplasty is affected by a large number of confounding variables each of which must be considered to enable valid interpretation. Relevant variables available from the 2011 NJR data set were included in the Cox model. Mortality rates in hip arthroplasty patients were lower than in the age-matched population across all hip types. Age at surgery, ASA grade, diagnosis, gender, provider type, hip type and lead surgeon grade all had a significant effect on mortality. Schemper's statistic showed that only 18.98% of the variation in mortality was explained by the variables available in the NJR data set. It is inappropriate to use NJR data to study an outcome affected by a multitude of confounding variables when these cannot be adequately accounted for in the available data set.
Resumo:
Background and purpose: The appropriate fixation method for hemiarthroplasty of the hip as it relates to implant survivorship and patient mortality is a matter of ongoing debate. We examined the influence of fixation method on revision rate and mortality.----- ----- Methods: We analyzed approximately 25,000 hemiarthroplasty cases from the AOA National Joint Replacement Registry. Deaths at 1 day, 1 week, 1 month, and 1 year were compared for all patients and among subgroups based on implant type.----- ----- Results: Patients treated with cemented monoblock hemiarthroplasty had a 1.7-times higher day-1 mortality compared to uncemented monoblock components (p < 0.001). This finding was reversed by 1 week, 1 month, and 1 year after surgery (p < 0.001). Modular hemiarthroplasties did not reveal a difference in mortality between fixation methods at any time point.----- ----- Interpretation: This study shows lower (or similar) overall mortality with cemented hemiarthroplasty of the hip.
Resumo:
The standard Exeter stem has a length of 150mm with offsets 37.5mm to 56mm. Shorter stems of lengths 95mm, 115mm and 125mm with offsets 35.5mm or less are available for patients with smaller femurs. Concern has been raised regarding the behaviour of the smaller implants. This paper analysed data from the Australian Orthopaedic Association National Joint Replacement Registry comparing survivorship of stems of offset 35.5mm or less with the standard stems of 37.5mm offset or greater. At seven years there was no significant difference in the Cumulative Percent Revision Rate in the short stems (3.4%, 95% CI 2.4-4.8%) compared with the standard length stems (3.5%, 95% CI 3.3-3.8%) despite its use in a greater proportion of potentially more difficult developmental dysplasia of the hip cases.
Resumo:
Since the inception of the first Joint Registry in Sweden in 1979, many countries including Finland, Norway, Denmark, Australia, New Zealand, Canada, Scotland, England and Wales now have more than 10 years experience and data, and are collecting data on more than 90% of the procedures performed nationally. There are also Joint Registries in Romania, Slovakia, Slovenia, Croatia, Hungary, France, Germany, Switzerland, Czech Republic, Italy, Austria and Portugal, and work is ongoing to develop a Joint Registry in the US...
Resumo:
Joint ventures can take many forms and can be formed for different reasons, from sharing resources to creating future business opportunities. At the same time, there is increasing interest and discussion of alternative procurement methods, moving away from traditional procurement systems to relational approaches. Business systems and strategies need to be redefined and move from a short-term project to project culture to a more strategic, long-term perspective. Joint ventures of construction organisations, global and local, have become increasingly popular to deliver large-scale infrastructure construction projects. However, successful strategic collaborations require project organisations to formulate a fit between contractual and operational arrangements for each situation. This study reviews the movement from traditional procurement methods towards relational contracting approaches in Queensland, Australia. The study examines the organisational factors that facilitates sustainable relationship between project organisations and hence, lead to long-term business success. This paper reports on initial findings captured from a survey undertaken with construction contracting organisations in Australia, focusing on the supply chain relationships. Contractors’ perceptions of the relationship management process and the engagement of the supply chain are also presented.
Resumo:
Background Patella resurfacing in total knee arthroplasty is a contentious issue. The literature suggests that resurfacing of the patella is based on surgeon preference, and little is known about the role and timing of resurfacing and how this affects outcomes. Methods We analyzed 134,799 total knee arthroplasties using data from the Australian Orthopaedic Association National Joint Replacement Registry. Hazards ratios (HRs) were used to compare rates of early revision between patella resurfacing at the primary procedure (the resurfacing group, R) and primary arthroplasty without resurfacing (no-resurfacing group, NR). We also analyzed the outcomes of NR that were revised for isolated patella addition. Results At 5 years, the R group showed a lower revision rate than the NR group: cumulative per cent revision (CPR) 3.1% and 4.0%, respectively (HR = 0.75, p < 0.001). Revisions for patellofemoral pain were more common in the NR group (17%) than in the R group (1%), and “patella only” revisions were more common in the NR group (29%) than in the R group (6%). Non-resurfaced knees revised for isolated patella addition had a higher revision rate than patella resurfacing at the primary procedure, with a 4-year CPR of 15% and 2.8%, respectively (HR = 4.1, p < 0.001). Interpretation Rates of early revision of primary total knees were higher when the patella was not resurfaced, and suggest that surgeons may be inclined to resurface later if there is patellofemoral pain. However, 15% of non-resurfaced knees revised for patella addition are re-revised by 4 years. Our results suggest an early beneficial outcome for patella resurfacing at primary arthroplasty based on revision rates up to 5 years.
Resumo:
This study determined the rate and indication for revision between cemented, uncemented, hybrid and resurfacing groups from NJR (6 th edition) data. Data validity was determined by interrogating for episodes of misclassification. We identified 6,034 (2.7%) misclassified episodes, containing 97 (4.3%) revisions. Kaplan-Meier revision rates at 3 years were 0.9% cemented, 1.9% for uncemented, 1.2% for hybrids and 3.0% for resurfacings (significant difference across all groups, p<0.001, with identical pattern in patients <55 years). Regression analysis indicated both prosthesis group and age significantly influenced failure (p<0.001). Revision for pain, aseptic loosening, and malalignment were highest in uncemented and resurfacing arthroplasty. Revision for dislocation was highest in uncemented hips (significant difference between groups, p<0.001). Feedback to the NJR on data misclassification has been made for future analysis. © 2012 Wichtig Editore.
Resumo:
Total hip arthroplasty (THA) has a proven clinical record for providing pain relief and return of function to patients with disabling arthritis. There are many successful options for femoral implant design and fixation. Cemented, polished, tapered femoral implants have been shown to have excellent results in national joint registries and long-term clinical series. These implants are usually 150mm long at their lateral aspect. Due to their length, these implants cannot always be offered to patients due to variations in femoral anatomy. Polished, tapered implants as short as 95mm exist, however their small proximal geometry (neck offset and body size) limit their use to smaller stature patients. There is a group of patients in which a shorter implant with a maintained proximal body size would be advantageous. There are also potential benefits to a shorter implant in standard patient populations such as reduced bone removal due to reduced reaming, favourable loading of the proximal femur, and the ability to revise into good proximal bone stock if required. These factors potentially make a shorter implant an option for all patient populations. The role of implant length in determining the stability of a cemented, polished, tapered femoral implant is not well defined by the literature. Before changes in implant design can be made, a better understanding of the role of each region in determining performance is required. The aim of the thesis was to describe how implant length affects the stability of a cemented, polished, tapered femoral implant. This has been determined through an extensive body of laboratory testing. The major findings are that for a given proximal body size, a reduction in implant length has no effect on the torsional stability of a polished, tapered design, while a small reduction in axial stability should be expected. These findings are important because the literature suggests that torsional stability is the major determinant of long-term clinical performance of a THA system. Furthermore, a polished, tapered design is known to be forgiving of cement-implant interface micromotion due to the favourable wear characteristics. Together these findings suggest that a shorter polished, tapered implant may be well tolerated. The effect of a change in implant length on the geometric characteristics of polished, tapered design were also determined and applied to the mechanical testing. Importantly, interface area does play a role in stability of the system; however it is the distribution of the interface and not the magnitude of the area that defines stability. Taper angle (at least in the range of angles seen in this work) was shown not to be a determinant of axial or torsional stability. A range of implants were tested, comparing variations in length, neck offset and indication (primary versus cement-in-cement revision). At their manufactured length, the 125mm implants were similar to their longer 150mm counterparts suggesting that they may be similarly well tolerated in the clinical environment. However, the slimmer cement-in-cement revision implant was shown to have a poorer mechanical performance, suggesting their use in higher demand patients may be hazardous. An implant length of 125mm has been shown to be quite stable and the results suggest that a further reduction to 100mm may be tolerated. However, further work is required. A shorter implant with maintained proximal body size would be useful for the group of patients who are unable to access the current standard length implants due to variations in femoral anatomy. Extending the findings further, the similar function with potential benefits of a shorter implant make their application to all patients appealing.
Resumo:
Head and neck cancers are some of the leading cancers in the coloured and black South African male population and the perception exists that the incidence rates are rising. Aims: To determine the standardised morbidity rates and some of the risk factors for oral cancer in South Africa. Methods: Using histologically verified data from the National Cancer Registry, the age standardised incidence rates (ASIR) and life-time risks (LR) of oral cancer in South Africa were calculated for 1988-1991.2. In an ongoing case control study (1995 +) among black patients in Johannesburg/Soweto, adjusted odds ratios for developing oral cancers in relation to tobacco and alcohol consumption were calculated. Results: Coloured males vs. females: ASIR 13.13 vs. 3.5 (/100,000/year), LR 1:65 vs. 1:244. Black males vs. females: ASIR 9.06 vs. 1.75, LR 1:86 and 1:455. White males vs. females: ASIR 8.06 vs. 3.18, LR 1:104 vs. 1:278. Asian males vs. females: ASIR 5.24 vs. 6.66, LR 1:161 vs. 1:125. The odds ratio for oral cancer in black males in relation to smoking was 7.0 (95% CI 3.0-14.6) and daily alcohol consumption 1.3 (95% CI 0.6-2.8). In black females the odds ratios in relation to smoking were 3.9 (95% CI 1.7 8.9) and daily alcohol consumption 1.7(95% CI 0.7-4.1). Conclusions: The risk factors for oral cancer in South Africa are multiple and gender discrepancies in ASIR and LR signal differences in exposure to carcinogens. It is unclear whether the incidence of oral cancers will rise in the future.
Resumo:
An increasing number of countries are faced with an aging population increasingly needing healthcare services. For any e-health information system, the need for increased trust by such clients with potentially little knowledge of any security scheme involved is paramount. In addition notable scalability of any system has become a critical aspect of system design, development and ongoing management. Meanwhile cryptographic systems provide the security provisions needed for confidentiality, authentication, integrity and non-repudiation. Cryptographic key management, however, must be secure, yet efficient and effective in developing an attitude of trust in system users. Digital certificate-based Public Key Infrastructure has long been the technology of choice or availability for information security/assurance; however, there appears to be a notable lack of successful implementations and deployments globally. Moreover, recent issues with associated Certificate Authority security have damaged trust in these schemes. This paper proposes the adoption of a centralised public key registry structure, a non-certificate based scheme, for large scale e-health information systems. The proposed structure removes complex certificate management, revocation and a complex certificate validation structure while maintaining overall system security. Moreover, the registry concept may be easier for both healthcare professionals and patients to understand and trust.
Resumo:
The refurbishment of The National Trust House (Basement3), undertaken in 2005, represents heritage consultation, architectural and interior design of a disused and deteriorating subbasement of a historically and culturally significant building situated in Brisbane. Research into rectification and restoration work of the existing structure and interior surfaces (inclusive of masonry work sourced from the Kangaroo Point quarry in the 1860's) formed a significant component of the project. The National Trust House sub basement 3 was refurbished to house the Architectural Practice Academy, a joint initiative of the Queensland Government and the Australian Institute of Architects.
Resumo:
Our cross-national field study of wine entrepreneurship in the “wrong” places provides some redress to the focus of the “regional advantage” literature on places that have already won and on the firms that benefit from “clusters” and other centers of industry advantage. Regional “disadvantage” is at best a shadowy afterthought to this literature. By poking around in these shadows, we help to synthesize and extend the incipient yet burgeoning literature on entrepreneurial “resourcefulness” and we contribute to the developing body of insights and theory pertinent to the numerous but often ignored firms and startups that mostly need to worry about how they will compete at all now if they are ever to have of chance of “winning” in the future. The core of our findings suggests that understandable – though contested – processes of ingenuity underlie entrepreneurial responses to regional disadvantage. Because we study entrepreneurship that from many angles simply does not make sense, we are also able to proffer a novel perspective on entrepreneurial sensemaking.
Resumo:
Objective: To (1) search the English-language literature for original research addressing the effect of cryotherapy on joint position sense (JPS) and (2) make recommendations regarding how soon healthy athletes can safely return to participation after cryotherapy. Data Sources: We performed an exhaustive search for original research using the AMED, CINAHL, MEDLINE, and SportDiscus databases from 1973 to 2009 to gather information on cryotherapy and JPS. Key words used were cryotherapy and proprioception, cryotherapy and joint position sense, cryotherapy, and proprioception. Study Selection: The inclusion criteria were (1) the literature was written in English, (2) participants were human, (3) an outcome measure included JPS, (4) participants were healthy, and (5) participants were tested immediately after a cryotherapy application to a joint. Data Extraction: The means and SDs of the JPS outcome measures were extracted and used to estimate the effect size (Cohen d) and associated 95% confidence intervals for comparisons of JPS before and after a cryotherapy treatment. The numbers, ages, and sexes of participants in all 7 selected studies were also extracted. Data Synthesis: The JPS was assessed in 3 joints: ankle (n 5 2), knee (n 5 3), and shoulder (n 5 2). The average effect size for the 7 included studies was modest, with effect sizes ranging from 20.08 to 1.17, with a positive number representing an increase in JPS error. The average methodologic score of the included studies was 5.4/10 (range, 5–6) on the Physiotherapy Evidence Database scale. Conclusions: Limited and equivocal evidence is available to address the effect of cryotherapy on proprioception in the form of JPS. Until further evidence is provided, clinicians should be cautious when returning individuals to tasks requiring components of proprioceptive input immediately after a cryotherapy treatment.
Resumo:
The Queensland University of Technology (QUT) in Brisbane, Australia, is involved in a number of projects funded by the Australian National Data Service (ANDS). Currently, QUT is working on a project (Metadata Stores Project) that uses open source VIVO software to aid in the storage and management of metadata relating to data sets created/managed by the QUT research community. The registry (called QUT Research Data Finder) will support the sharing and reuse of research datasets, within and external to QUT. QUT uses VIVO for both the display and the editing of research metadata.