Knowledge of the accuracy of dose calculations in intensity-modulated radiotherapy of the head and neck is essential for clinical confidence in these highly conformal treatments. High dose gradients are frequently placed very close to critical structures, such as the spinal cord, and good coverage of complex shaped nodal target volumes is important for long term-local control. A phantom study is presented comparing the performance of standard clinical pencil-beam and collapsed-cone dose algorithms to Monte Carlo calculation and three-dimensional gel dosimetry measurement. All calculations and measurements are normalized to the median dose in the primary planning target volume, making this a purely relative study. The phantom simulates tissue, air and bone for a typical neck section and is treated using an inverse-planned 5-field IMRT treatment, similar in character to clinically used class solutions. Results indicate that the pencil-beam algorithm fails to correctly model the relative dose distribution surrounding the air cavity, leading to an overestimate of the target coverage. The collapsed-cone and Monte Carlo results are very similar, indicating that the clinical collapsed-cone algorithm is perfectly sufficient for routine clinical use. The gel measurement shows generally good agreement with the collapsed-cone and Monte Carlo calculated dose, particularly in the spinal cord dose and nodal target coverage, thus giving greater confidence in the use of this class solution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study the interplay effects for Enhanced Dynamic Wedge (EDW) treatments are experimentally investigated. Single and multiple field EDW plans for different wedge angles were delivered to a phantom and detector on a moving platform, with various periods, amplitudes for parallel and perpendicular motions. A four field 4D CT planned lung EDW treatment was delivered to a dummy tumor over four fractions. For the single field parallel case the amplitude and the period of motion both affect the interplay resulting in the appearance of a step function and penumbral cut off with the discrepancy worst where collimator-tumor speed is similar. For perpendicular motion the amplitude of tumor motion is the only dominant factor. For large wedge angle the dose discrepancy is more pronounced compared to the small wedge angle for the same field size and amplitude-period values. For a small field size i.e. 5 × 5 cm2 the loss of wedged distribution was observed for both 60º and 15º wedge angles for of parallel and perpendicular motions. Film results from 4D CT planned delivery displayed a mix of over and under dosages over 4 fractions, with the gamma pass rate of 40% for the averaged film image at 3%/1 mm DTA (Distance to Agreement). Amplitude and period of the tumor motion both affect the interplay for single and multi-field EDW treatments and for a limited (4 or 5) fraction delivery there is a possibility of non-averaging of the EDW interplay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Forty-six bottled water samples representing 16 brands from Dhaka, Bangladesh were tested for the numbers of total coliforms, fecal indicator bacteria (i.e., thermotolerant Escherichia coli and Enterococcus spp.) and potential bacterial pathogens (i.e., Aeromonas hydrophil, Pseudomonas aeruginos, Salmonella spp., and Shigella spp.). Among the 16 brands tested, 14 (86%), ten (63%) and seven (44%) were positive for total coliforms, E. coil and Enterococcus spp., respectively. Additionally, a further nine (56%), eight (50%), six (37%), and four (25%) brands were PCR positive for A. hydrophila lip, P. aeruginosa ETA, Salmonella spp. invA, and Shigella spp. ipaH genes, respectively. The numbers of bacterial pathogens in bottled water samples ranged from 28 ± 12 to 600 ± 45 (A. hydrophila lip gene), 180 ± 40 to 900 ± 200 (Salmonella spp. invA gene), 180 ± 40 to 1,300 ± 400 (P. aeruginosa ETA gene) genomic units per L of water. Shigella spp. ipaH gene was not quantifiable. Discrepancies were observed in terms of the occurrence of fecal indicators and bacterial pathogens. No correlations were observed between fecal indicators numbers and presence/absence of A. hydrophila lip (p = 0.245), Salmonella spp. invA (p = 0.433), Shigella spp. ipaH gene (p = 0.078), and P. aeruginosa ETA (p = 0.059) genes. Our results suggest that microbiological quality of bottled waters sold in Dhaka, Bangladesh is highly variable. To protect public health, stringent quality control is recommended for the bottled water industry in Bangladesh. Key words: bottled water, fecal indicator bacteria, quantitative PCR, bacterial pathogens, public health risk.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large scale exome sequencing studies have revealed regions of the genome, which contribute to the castrate resistant prostate cancer (CRPC) phenotype. [1],[2],[3] Such studies have identified mutations in genes, which may have diagnostic/prognostic potential, or which may be targeted therapeutically. Two of these genes include the androgen receptor (AR) and speckle-type POZ protein (SPOP) genes. However, the findings from these exome sequencing studies can only be translated therapeutically once the functional consequences of these mutations have been determined. Here, we highlight the recent study by An et al. [4] which investigated the functional effects of mutations in the SPOP gene that were identified in the aforementioned exome sequencing studies, particularly in the context of SPOP-mediated degradation of the AR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Prescription medicine samples provided by pharmaceutical companies are predominantly newer and more expensive products. The range of samples provided to practices may not represent the drugs that the doctors desire to have available. Few studies have used a qualitative design to explore the reasons behind sample use. Objective The aim of this study was to explore the opinions of a variety of Australian key informants about prescription medicine samples, using a qualitative methodology. Methods Twenty-three organizations involved in quality use of medicines in Australia were identified, based on the authors' previous knowledge. Each organization was invited to nominate 1 or 2 representatives to participate in semistructured interviews utilizing seeding questions. Each interview was recorded and transcribed verbatim. Leximancer v2.25 text analysis software (Leximancer Pty Ltd., Jindalee, Queensland, Australia) was used for textual analysis. The top 10 concepts from each analysis group were interrogated back to the original transcript text to determine the main emergent opinions. Results A total of 18 key interviewees representing 16 organizations participated. Samples, patient, doctor, and medicines were the major concepts among general opinions about samples. The concept drug became more frequent and the concept companies appeared when marketing issues were discussed. The Australian Pharmaceutical Benefits Scheme and cost were more prevalent in discussions about alternative sample distribution models, indicating interviewees were cognizant of budgetary implications. Key interviewee opinions added richness to the single-word concepts extracted by Leximancer. Conclusions Participants recognized that prescription medicine samples have an influence on quality use of medicines and play a role in the marketing of medicines. They also believed that alternative distribution systems for samples could provide benefits. The cost of a noncommercial system for distributing samples or starter packs was a concern. These data will be used to design further research investigating alternative models for distribution of samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction We have previously shown that the concentrations of D-dimer are significantly elevated in saliva compared with plasma. Saliva offers several advantages compared with blood analysis. We hypothesised that human saliva contains plasminogen activator inhibitor-1 (PAI-1) and that the concentrations are not affected by the time of saliva collection. The aim was to adopt and validate an immunoassay to quantify PAI-1 concentrations in saliva and to determine whether saliva collection time has an influence in the measurement. Materials and methods Two saliva samples (morning and afternoon) from the same day were collected from healthy subjects (N = 40) who have had no underlying heart conditions. A customized AlphaLISA® immunoassay (PerkinElmer®, MA, USA) was adopted and used to quantify PAI-1 concentrations. We validated the analytical performance of the customized immunoassay by calculating recovery of known amount of analyte spiked in saliva. Results: The recovery (95.03%), intra- (8.59%) and inter-assay (7.52%) variations were within the acceptable ranges. The median salivary PAI-1 concentrations were 394 pg/mL (interquartile ranges (IQR) 243.4-833.1 pg/mL) in the morning and 376 (129.1-615.4) pg/mL in the afternoon and the plasma concentration was 59,000 (24,000-110,000) pg/mL. Salivary PAI-1 did not correlate with plasma (P = 0.812). Conclusions The adopted immunoassay produced acceptable assay sensitivity and specificity. The data demonstrated that saliva contains PAI-1 and that its concentration is not affected by the time of saliva collection. There is no correlation between salivary and plasma PAI-1 concentrations. Further studies are required to demonstrate the utility of salivary PAI-1 in CVD risk factor studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study investigates the effects of temporary tissue expanders (TTEs) on the dose distributions in breast cancer radiotherapy treatments under a variety of conditions. Methods: Using EBT2 radiochromic film, both electron and photon beam dose distribution measurements were made for different phantoms, and beam geometries. This was done to establish a more comprehensive understanding of the implant’s perturbation effects under a wider variety of conditions. Results: The magnetic disk present in a tissue expander causes a dose reduction of approximately 20% in a photon tangent treatment and 56% in electron boost fields immediately downstream of the implant. The effects of the silicon elastomer are also much more apparent in an electron beam than a photon beam. Conclusions: Evidently, each component of the TTE attenuates the radiation beam to different degrees. This study has demonstrated that the accuracy of photon and electron treatments of post-mastectomy patients is influenced by the presence of a tissue expander for various beam orientations. The impact of TTEs on dose distributions establishes the importance of an accurately modelled high-density implant in the treatment planning system for post-mastectomy patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: The purpose of this pilot study was to introduce knee alignment as a potential predictor of sedentary activity levels in boys and girls. METHODS: Dual energy x-ray absorptiometry (DXA) and anthropometric assessment were conducted on 47 children (21 boys and 26 girls; 5-14 y) and their gender-matched parent. Body Mass Index (BMI) and abdominal-to-height ratio were calculated. Lower extremity alignment was determined by anatomic tibiofemoral angle (TFA) measurements from DXA images. Time spent in moderate-to-vigorous physical activity and sedentary activities were obtained from a parent-reported questionnaire. Stepwise multiple regression analyses identified anthropometric, musculoskeletal, and activity factors of parents and children for predicting total time spent in sedentary behaviour. RESULTS: Weight, total sedentary time of parents and TFA are moderate predictors of sedentary behaviour in children (R2=0.469). When stratifying for gender, TFA and total sedentary time of the parent, as well as waist circumference, are the most useful predictors of sedentary behaviour in boys (R2=0.648). However, weight is the only predictor of sedentary behaviour in girls (R2=0.479). CONCLUSION: Negative associations between TFA and sedentary behaviour indicate that even slight variations in musculoskeletal alignment may influence a child's motivation to be physically active. Although growth and development is complicated by many potentialities, this pilot study suggests that orthopaedic factors should also be considered when evaluating physical activity in children

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite recent therapeutic advances, acute ischemic complications of atherosclerosis remain the primary cause of morbidity and mortality in Western countries, with carotid atherosclerotic disease one of the major preventable causes of stroke. As the impact of this disease challenges our healthcare systems, we are becoming aware that factors influencing this disease are more complex than previously realized. In current clinical practice, risk stratification relies primarily on evaluation of the degree of luminal stenosis and patient symptomatology. Adequate investigation and optimal imaging are important factors that affect the quality of a carotid endarterectomy (CEA) service and are fundamental to patient selection. Digital subtraction angiography is still perceived as the most accurate imaging modality for carotid stenosis and historically has been the cornerstone of most of the major CEA trials but concerns regarding potential neurological complications have generated substantial interest in non-invasive modalities, such as contrast-enhanced magnetic resonance angiography. The purpose of this review is to give an overview to the vascular specialist of the current imaging modalities in clinical practice to identify patients with carotid stenosis. Advantages and disadvantages of each technique are outlined. Finally, limitations of assessing luminal stenosis in general are discussed. This article will not cover imaging of carotid atheroma morphology, function and other emerging imaging modalities of assessing plaque risk, which look beyond simple luminal measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An open-label inpatient study is in progress to compare the efficacy and safety of two oral rehydration solutions in children and infants with acute diarrhea and mild to moderate dehydration. One solution (ORS-60) contains 60 mmol/L of sodium and 1.8% glucose, with a total osmolatity of 240 mosm/kg; the other (ORS-26) contains 26 mmol/L of sodium, 2.7% glucose, and 3.6% sucrose, with a total osmolality of 340 mosm/kg. An outcome analysis of 28 children with gastroenteritis indicated that ORS-60 (n = 13) reduced stool volume during the first eight hours after admission to a significantly greater (P < 0.05) extent than did ORS-26 (n = 15). Diarrhea had ceased by 24 hours in 64% of ORS-60 patients but in only 31% of ORS-26 patients, and the patients' clinical conidition was improved at eight hours in 84% of ORS-60 patients versus 60% of ORS-26 patients. Differences between treatments in degree of dehydration at each follow-up point, total duration of diarrhea, and duration of hospital stay were not detected. No adverse drug reactions occurred. Four patients received intravenous rehydration therapy, but none was considered a treatment failure. We conclude that the lower osmolar solution, ORS-60, conferred earlier recovey and reduced continuing fluid losses in the management of gastroenteritis.