315 resultados para Laboratory test

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The branded pause advertisement is a recently developed online television-advertising format that displays a full-screen still-image banner ad whenever a viewer pauses a streaming-video program. This study used a controlled lab experiment to compare the effectiveness of branded pause advertisements with normal online television advertisements. The results demonstrate that branded pause advertisements are effective but only when combined with a long-exposure advertisement for the same brand. Despite their short exposure time, pause advertisements function as effective reminders, building awareness through repeat exposure. The findings of the current study were similar regardless of whether pause advertisements were activated as a result of viewers’ pausing at a time of their own choosing or whether viewers were interrupted.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Detection of faults in roller element bearing is a topic widely discussed in the scientific field. Bearings diagnostics is usually performed by analyzing experimental signals, almost always vibration signals, measured during operation. A number of signal processing techniques have been proposed and applied to measured vibrations. The diagnostic effectiveness of the techniques depends on their capacities and on the environmental conditions (i.e. environmental noise). The current trend, especially from an industrial point of view, is to couple the prognostics to the diagnostics. The realization of a prognostic procedure require the definition of parameters able to describe the bearing condition during its operation. Monitoring the values of these parameters during time allows to define their trends depending on the progress of the wear. In this way, a relation between the variation of the selected parameters and the wear progress, useful for diagnostics and prognostics of bearings in real industrial applications, can be established. In this paper, a laboratory test-rig designed to perform endurance tests on roller element bearing is presented. Since the test-rig has operated for a short time, only some preliminary available results are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The process of structural health monitoring (SHM) involves monitoring a structure over a period of time using appropriate sensors, extracting damage sensitive features from the measurements made by the sensors and analysing these features to determine the current state of the structure. Various techniques are available for structural health monitoring of structures and acoustic emission (AE) is one technique that is finding an increasing use. Acoustic emission waves are the stress waves generated by the mechanical deformation of materials. AE waves produced inside a structure can be recorded by means of sensors attached on the surface. Analysis of these recorded signals can locate and assess the extent of damage. This paper describes preliminary studies on the application of AE technique for health monitoring of bridge structures. Crack initiation or structural damage will result in wave propagation in solid and this can take place in various forms. Propagation of these waves is likely to be affected by the dimensions, surface properties and shape of the specimen. This, in turn, will affect source localization. Various laboratory test results will be presented on source localization, using pencil lead break tests. The results from the tests can be expected to aid in enhancement of knowledge of acoustic emission process and development of effective bridge structure diagnostics system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis describes outcomes of a research study conducted to investigate the nutrient build-up and wash-off processes on urban impervious surfaces. The data needed for the study was generated through a series of field investigations and laboratory test procedures. The study sites were selected in urbanised catchments to represent typical characteristics of residential, industrial and commercial land uses. The build-up and wash-off samples were collected from road surfaces in the selected study sites. A specially designed vacuum collection system and a rainfall simulator were used for sample collection. According to the data analysis, the solids build-up on road surfaces was significantly finer with more than 80% of the particles below 150 ìm for all the land uses. Nutrients were mostly associated with the particle size range below 150 ìm in both build-up and wash-off samples irrespective of type of land use. Therefore, the finer fraction of solids was the most important for the nutrient build-up and particulate nutrient wash-off processes. Consequently, the design of stormwater quality mitigation measures should target particles less than 150 ìm for the removal of nutrients irrespective of type of land use. Total kjeldahl nitrogen (TKN) was the most dominant form of nitrogen species in build-up on road surfaces. Phosphorus build-up on road surfaces was mainly in inorganic form and phosphate (PO4 3-) was the most dominant form. The nutrient wash-off process was found to be dependent on rainfall intensity and duration. Concentration of both total nitrogen and phosphorus was higher at the beginning of the rain event and decreased with the increase in rainfall duration. Consequently, in the design of stormwater quality mitigation strategies for nutrients removal, it is important to target the initial period of rain events. The variability of wash-off of nitrogen with rainfall intensity was significantly different to phosphorus wash-off. The concentration of nitrogen was higher in the wash-off for low intensity rain events compared to the wash-off for high intensity rain events. On the other hand, the concentration of phosphorus in the wash-off was high for high intensity rain events compared to low intensity rain events. Consequently, the nitrogen washoff can be defined as a source limiting process and phosphorus wash-off as a transport limiting process. This highlights the importance of taking into consideration the wash-off of low intensity rain events in the design of stormwater quality mitigation strategies targeting the nitrogen removal. All the nitrogen species in wash-off are primarily in dissolved form whereas phosphorus is in particulate form. The differences in the nitrogen and phosphorus wash-off processes is principally due to the degree of solubility, attachment to particulates, composition of total nitrogen and total phosphorus and the degree of adherence of the solids particles to the surface to which nutrients are attached. The particulate nitrogen available for wash-off is removed readily as these are mobilised as free solids particles on the surface. Phosphorus is washed-off mostly with the solids particles which are strongly adhered to the surface or as the fixed solids load. Investigation of the nitrogen wash-off process using bulk wash-off samples was in close agreement with the investigation of dissolved fraction of wash-off solids. This was primarily due to the predominant nature of dissolved nitrogen. However, the investigation of the processes which underpin phosphorus wash-off using bulk washoff samples could lead to loss of information. This is due to the composition of total phosphorus in wash-off solids and the inherent variability of the wash-off process for the different particle size ranges. This variability should preferably be taken into consideration as phosphorus wash-off is predominantly in particulate form. Therefore, care needs to be taken in the investigation of the phosphorus wash-off process using bulk wash-off samples to ensure that there is no loss of information and hence result in misleading outcomes. The investigation of different particle size ranges of wash-off solids is preferable in the interest of designing effective stormwater quality management strategies targeting phosphorus removal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An algorithm based on the concept of combining Kalman filter and Least Error Square (LES) techniques is proposed in this paper. The algorithm is intended to estimate signal attributes like amplitude, frequency and phase angle in the online mode. This technique can be used in protection relays, digital AVRs, DGs, DSTATCOMs, FACTS and other power electronics applications. The Kalman filter is modified to operate on a fictitious input signal and provides precise estimation results insensitive to noise and other disturbances. At the same time, the LES system has been arranged to operate in critical transient cases to compensate the delay and inaccuracy identified because of the response of the standard Kalman filter. Practical considerations such as the effect of noise, higher order harmonics, and computational issues of the algorithm are considered and tested in the paper. Several computer simulations and a laboratory test are presented to highlight the usefulness of the proposed method. Simulation results show that the proposed technique can simultaneously estimate the signal attributes, even if it is highly distorted due to the presence of non-linear loads and noise.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With the rapid increase in electrical energy demand, power generation in the form of distributed generation is becoming more important. However, the connections of distributed generators (DGs) to a distribution network or a microgrid can create several protection issues. The protection of these networks using protective devices based only on current is a challenging task due to the change in fault current levels and fault current direction. The isolation of a faulted segment from such networks will be difficult if converter interfaced DGs are connected as these DGs limit their output currents during the fault. Furthermore, if DG sources are intermittent, the current sensing protective relays are difficult to set since fault current changes with time depending on the availability of DG sources. The system restoration after a fault occurs is also a challenging protection issue in a converter interfaced DG connected distribution network or a microgrid. Usually, all the DGs will be disconnected immediately after a fault in the network. The safety of personnel and equipment of the distribution network, reclosing with DGs and arc extinction are the major reasons for these DG disconnections. In this thesis, an inverse time admittance (ITA) relay is proposed to protect a distribution network or a microgrid which has several converter interfaced DG connections. The ITA relay is capable of detecting faults and isolating a faulted segment from the network, allowing unfaulted segments to operate either in grid connected or islanded mode operations. The relay does not make the tripping decision based on only the fault current. It also uses the voltage at the relay location. Therefore, the ITA relay can be used effectively in a DG connected network in which fault current level is low or fault current level changes with time. Different case studies are considered to evaluate the performance of the ITA relays in comparison to some of the existing protection schemes. The relay performance is evaluated in different types of distribution networks: radial, the IEEE 34 node test feeder and a mesh network. The results are validated through PSCAD simulations and MATLAB calculations. Several experimental tests are carried out to validate the numerical results in a laboratory test feeder by implementing the ITA relay in LabVIEW. Furthermore, a novel control strategy based on fold back current control is proposed for a converter interfaced DG to overcome the problems associated with the system restoration. The control strategy enables the self extinction of arc if the fault is a temporary arc fault. This also helps in self system restoration if DG capacity is sufficient to supply the load. The coordination with reclosers without disconnecting the DGs from the network is discussed. This results in increased reliability in the network by reduction of customer outages.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Carbon fibre reinforced polymer (CFRP) sheets have many outstanding properties such as high strength, high elastic modulus, light weight and good durability which are made them a suitable alternative for steel in strengthening work. This paper describe the ultimate load carrying capacity of steel hollow sections at effective bond length in terms of its cross sectional area and the stress distribution within bond region for different layers CFRP. It was found that depending on their size and orientation of uni- directional CFRP layers, the ultimate tensile load was different. Along with these tests, non linear finite element analysis was also performed to validate the ultimate load carrying capacity depending on their cross sections. The predicted ultimate loads from FE analysis are found very close to the laboratory test results. The validated model has been used to determine the stress distribution at bond joint for different orientation of CFRP. This research shows the effect of stress distribution and suitable wrapping layer to be used for the strengthening of steel hollow sections in tension.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diagnostics of rolling element bearings have been traditionally developed for constant operating conditions, and sophisticated techniques, like Spectral Kurtosis or Envelope Analysis, have proven their effectiveness by means of experimental tests, mainly conducted in small-scale laboratory test-rigs. Algorithms have been developed for the digital signal processing of data collected at constant speed and bearing load, with a few exceptions, allowing only small fluctuations of these quantities. Owing to the spreading of condition based maintenance in many industrial fields, in the last years a need for more flexible algorithms emerged, asking for compatibility with highly variable operating conditions, such as acceleration/deceleration transients. This paper analyzes the problems related with significant speed and load variability, discussing in detail the effect that they have on bearing damage symptoms, and propose solutions to adapt existing algorithms to cope with this new challenge. In particular, the paper will i) discuss the implication of variable speed on the applicability of diagnostic techniques, ii) address quantitatively the effects of load on the characteristic frequencies of damaged bearings and iii) finally present a new approach for bearing diagnostics in variable conditions, based on envelope analysis. The research is based on experimental data obtained by using artificially damaged bearings installed on a full scale test-rig, equipped with actual train traction system and reproducing the operation on a real track, including all the environmental noise, owing to track irregularity and electrical disturbances of such a harsh application.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Unbalanced or non-linear loads result in distorted stator currents and electromagnetic torque pulsations in stand-alone doubly fed induction generators (DFIGs). This study proposes the use of a proportional-integral repetitive control (PIRC) scheme so as to mitigate the levels of harmonic and unbalance at the stator terminals of the DFIG. The PIRC is structurally simpler and requires much less computation than existing methods. Analysis of the PIRC operation and the methodology to determine the control parameters is included. Simulation study as well as laboratory test measurements demonstrate clearly the effectiveness of the proposed PIRC control scheme.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There are limited community-based data on the burden of influenza and influenza-like illnesses during pregnancy to inform disease surveillance and control. We aimed to determine the incidence of medically-attended respiratory illnesses (MARI) in pregnant women and the proportion of women who are tested for respiratory pathogens at these visits. We conducted a nested retrospective cohort study of a non-random sample of women aged ≥18 years who had a live birth in maternity units in Brisbane, Queensland, from March 2012 to October 2014. The primary outcomes were self-reported doctor visits for MARI and laboratory investigations for respiratory pathogens. Descriptive analyses were performed. Among 1202 participants, 222 (18.5%, 95%CI 16.3%-20.7%) self-reported MARI during their pregnancy. Of those with an MARI, 20.3% (45/222) self-reported a laboratory test was performed. We were able to confirm with health service providers that 46.7% (21/45) of tests were undertaken, responses from providers were not received for the remainder. Whilst one in five women in this population reported a MARI in pregnancy, only 3.7% (45/1202) reported a clinical specimen had been arranged at the consultation and the ability to validate that self-report was problematic. As the focus on maternal immunisation increases, ascertainment of the aetiological agent causing MARI in this population will be required and efficient and reliable methods for obtaining those data at the community level need to be established.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background In the emergency department, portable point-of-care testing (POCT) coagulation devices may facilitate stroke patient care by providing rapid International Normalized Ratio (INR) measurement. The objective of this study was to evaluate the reliability, validity, and impact on clinical decision-making of a POCT device for INR testing in the setting of acute ischemic stroke (AIS). Methods A total of 150 patients (50 healthy volunteers, 51 anticoagulated patients, 49 AIS patients) were assessed in a tertiary care facility. The INR's were measured using the Roche Coaguchek S and the standard laboratory technique. Results The interclass correlation coefficient and 95% confidence interval between overall POCT device and standard laboratory value INRs was high (0.932 (0.69 - 0.78). In the AIS group alone, the correlation coefficient and 95% CI was also high 0.937 (0.59 - 0.74) and diagnostic accuracy of the POCT device was 94%. Conclusions When used by a trained health professional in the emergency department to assess INR in acute ischemic stroke patients, the CoaguChek S is reliable and provides rapid results. However, as concordance with laboratory INR values decreases with higher INR values, it is recommended that with CoaguChek S INRs in the > 1.5 range, a standard laboratory measurement be used to confirm the results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To evaluate malnutrition in chronic liver disease, and its relationship to nutrient deficiencies and hepatic dysfunction. 27 children with end-stage liver disease were studied. Mean protein-energy intakes were 70% of recommended daily intakes. The patients were underweight and stunted with reduced mean triceps and subscapular skinfold thicknesses and midupper arm circumference. Mean total body potassium was only 63 ± 18% of that expected for age and sex. Deficiency of essential fatty acids (32%), and low concentrations of fat-soluble vitamins (A, 92%; E, 32%), iron (32%), zinc (42%), and selenium (13%) were common. Serum ammonia concentrations were raised in all patients, and increased methionine, tyrosine, and glutamic acid, and reduced glutamine concentrations were noted. There was no correlation between the degree of malnutrition and the degree of liver synthetic function, the degree of cholestasis, or the degree of liver injury. We suggest that potentially correctable factors in addition to liver failure (eg, inadequate absorbed intake) were important determinants of malnutrition in these patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cyclic plastic deformation of subgrade and other engineered layers is generally not taken into account in the design of railway bridge transition zones, although the plastic deformation is the governing factor of frequent track deterioration. Actual stress behavior of fine grained subgrade/embankment layers under train traffic is, however, difficult to replicate using the conventional laboratory test apparatus and techniques. A new type of torsional simple shear apparatus, known as multi-ring shear apparatus, was therefore developed to evaluate the actual stress state and the corresponding cyclic plastic deformation characteristics of subgrade materials under moving wheel load conditions. Multi-ring shear test results has been validated using a theoretical model test results; the capability of the multi-ring shear apparatus for replicating the cyclic plastic deformation characteristics of subgrade under moving train wheel load conditions is thus established. This paper describes the effects of principal stress rotation (PSR) of the subgrade materials to the cyclic plastic deformation in a railroad and impacts of testing methods in evaluating the influence of principal stress rotation to the track deterioration of rail track.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Emerging contaminants (ECs) are chemical compounds commonly present in water. It is only recently that this family of compounds is being recognized as significant water pollutants (. ECs include a wide variety of chemicals such as pharmaceutical and personal care products (PPCPs), pesticides, hydrocarbons and hormones, among others, that once released into the environment exert adverse impacts on the human and wildlife endocrine system. Natural attenuation and conventional treatment processes are not capable of removing these micro-pollutants detected in wastewater influent and effluent and surface and drinking water. The main challenges related with presence of ECs in stormwater in the context of reuse are: a) Development of suitable laboratory test methodologies and protocols for ECs identification and quantification b) Identification of the sources of ECs in the urban environment; c) Understanding their impacts on human and/or ecosystem health; and d). Development of cost-effective removal technologies which are appropriate for large as well as small-scale application.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Many researchers in the field of civil structural health monitoring (SHM) have developed and tested their methods on simple to moderately complex laboratory structures such as beams, plates, frames, and trusses. Fieldwork has also been conducted by many researchers and practitioners on more complex operating bridges. Most laboratory structures do not adequately replicate the complexity of truss bridges. Informed by a brief review of the literature, this paper documents the design and proposed test plan of a structurally complex laboratory bridge model that has been specifically designed for the purpose of SHM research. Preliminary results have been presented in the companion paper.