18 resultados para Kerstin Ekman
em Queensland University of Technology - ePrints Archive
Resumo:
This study directly measured the load acting on the abutment of the osseointegrated implant system of transfemoral amputees during level walking, and studied the variability of the load within and among amputees. Twelve active transfemoral amputees (age: 54±12 years, mass:84.3±16.3 kg, height: 17.8±0.10 m) fitted with an osseointegrated implant for over 1 year participated in the study. The load applied on the abutment was measured during unimpeded, level walking in a straight line using a commercial six-channel transducer mounted between the abutment and the prosthetic knee. The pattern and the magnitude of the three-dimensional forces and moments were revealed. Results showed a low step-to-step variability of each subject, but a high subject-to-subject variability in local extrema of body-weight normalized forces and moments and impulse data. The high subject-to-subject variability suggests that the mechanical design of the implant system should be customized for each individual, or that a fit-all design should take into consideration the highest values of load within a broad range of amputees. It also suggests specific loading regime in rehabilitation training are necessary for a given subject. Thus the loading magnitude and variability demonstrated should be useful in designing an osseointegrated implant system better able to resist mechanical failure and in refining the rehabilitation protocol.
Resumo:
The purpose of this study was to characterise the functional outcome of 12 transfemoral amputees fitted with osseointegrated fixation using temporal gait characteristics. The objectives were (A) to present the cadence, duration of gait cycle, support and swing phases with an emphasis on the stride-to-stride and participant-to-participant variability, and (B) to compare these temporal variables with normative data extracted from the literature focusing on transfemoral amputees fitted with a socket and able-bodied participants. The temporal variables were extracted from the load applied on the residuum during straight level walking, which was collected at 200 Hz by a transducer. A total of 613 strides were assessed. The cadence (46±4 strides/min), the duration of the gait cycle (1.29±0.11 s), support (0.73±0.07 s, 57±3% of CG) and swing (0.56±0.07 s, 43±3% of GC) phases of the participants were 2% quicker, 3%, 6% shorter and 1% longer than transfemoral amputees using a socket as well as 11% slower, 9%, 6% and 13% longer than able-bodied, respectively. All combined, the results indicated that the fitting of an osseointegrated fixation has enabled this group of amputees to restore their locomotion with a highly functional level. Further longitudinal and cross-sectional studies would be required to confirm these outcomes. Nonetheless, the data presented can be used as benchmark for future comparisons. It can also be used as input in generic algorithms using templates of patterns of loading to recognise activities of daily living and to detect falls.
Resumo:
The purpose of this proof-of-concept study was to determine the relevance of direct measurements to monitor the load applied on the osseointegrated fixation of transfemoral amputees during static load bearing exercises. The objectives were (A) to introduce an apparatus using a three-dimensional load transducer, (B) to present a range of derived information relevant to clinicians, (C) to report on the outcomes of a pilot study and (D) to compare the measurements from the transducer with those from the current method using a weighing scale. One transfemoral amputee fitted with an osseointegrated implant was asked to apply 10 kg, 20 kg, 40 kg and 80 kg on the fixation, using self-monitoring with the weighing scale. The loading was directly measured with a portable kinetic system including a six-channel transducer, external interface circuitry and a laptop. As the load prescribed increased from 10 kg to 80 kg, the forces and moments applied on and around the antero-posterior axis increased by 4 fold anteriorly and 14 fold medially, respectively. The forces and moments applied on and around the medio-lateral axis increased by 9 fold laterally and 16 fold from anterior to posterior, respectively. The long axis of the fixation was overloaded and underloaded in 17 % and 83 % of the trials, respectively, by up to ±10 %. This proof-of-concept study presents an apparatus that can be used by clinicians facing the challenge of improving basic knowledge on osseointegration, for the design of equipment for load bearing exercises and for rehabilitation programs.
Resumo:
Introduction Stretching of tissue stimulates angiogenesis but increased motion at a fracture site hinders revascularisation. In vitro studies have indicated that mechanical stimuli promote angiogenic responses in endothelial cells, but can either inhibit or enhance responses when applied directly to angiogenesis assays. We anticipated that cyclic tension applied during endothelial network assembly would increase vascular structure formation up to a certain threshold. Methods Fibroblast/HUVEC co-cultures were subjected to cyclic equibiaxial strain (1 Hz; 6 h/day; 7 days) using the FlexerCell FX-4000T system and limiting rings for simultaneous application of multiple strain magnitudes (0–13%). Cells were labelled using anti-PECAM-1, and image analysis provided measures of endothelial network length and numbers of junctions. Results Cyclic stretching had no significant effect on the total length of endothelial networks (P > 0.2) but resulted in a strain-dependent decrease in branching and localised alignments of endothelial structures, which were in turn aligned with the supporting fibroblastic construct. Conclusion The organisation of endothelial networks under cyclic strain is dominated by structural adaptation to the supporting construct. It may be that, in fracture healing, the formation and integrity of the granulation tissue and callus is ultimately critical in revascularisation and its failure under severe strain conditions.
Resumo:
The present study was conducted to investigate whether ob- servers are equally prone to overlook any kinds of visual events in change blindness. Capitalizing on the finding from visual search studies that abrupt appearance of an object effectively captures observers' attention, the onset of a new object and the offset of an existing object were contrasted regarding their detectability when they occurred in a naturalistic scene. In an experiment, participants viewed a series of photograph pairs in which layouts of seven or eight objects were depicted. One object either appeared in or disappeared from the layout, and participants tried to detect this change. Results showed that onsets were detected more quickly than offsets, while they were detected with equivalent ac- curacy. This suggests that the primacy of onset over offset is a robust phenomenon that likely makes onsets more resistant to change blindness under natural viewing conditions.
Resumo:
The aim of this paper is to aid researchers in undertaking action research within industry with a particular focus on the study of design-led innovation. This paper presents the research design of a case study shaped to solve real world problems concerning a major Australian Airport Corporation by bridging the chasm between academia and industry. The researcher’s role is one of design-innovation catalyst, facilitating the integration of design as a new strategic capability and innovation approach within an organisation’s fabric. A discussion of the researcher experience within industry will provide evidence on the challenges facing such a research role, with strategies for overcoming these barriers presented. Based on the authors’ experience as a researcher within industry and reflection within practice, a project progression model for action research is presented to enable the improved management of industry based research.
Resumo:
As global industries change and technology advances, traditional education systems may no longer be able to supply companies with graduates possessing an appropriate mix of skills and experience. The recent increased interest in Design Thinking as an approach to innovation has resulted in its adoption by non-design trained professionals. This necessitates a new method of teaching Design Thinking related skills and processes. This research investigates what (content) and how (assessment and learning modes) Design Thinking is being taught from fifty-one (51) selected courses across twenty-eight (28) international universities. Their approaches differ, with some universities specifically investing in design schools and programs, while others embed Design Thinking holistically throughout the university. Business, engineering and design schools are all expanding their efforts to teach students how to innovate, often through multi-disciplinary classes. This paper presents ‘The Educational Design Ladder’ a resource model, which suggests a process for the organisation and structuring of units for a multi-disciplinary Design Thinking program. The intention is to provide 21st century graduates with the right combination of skills and experience to solve workplace design problems regardless of their core discipline.
Resumo:
A need to respond to changing legislative requirements, rising expectations from customers and shortages of suitably experienced staff are forcing non-profit organisations in the aged care sector to change. As new customer segments emerge and the existing aged care offering becomes less relevant, organisations must rethink the value they present to market, and adopt innovative strategies and approaches to care delivery in order to have a sustainable future. This paper presents a framework for unpacking a customer journey and experience, developed during a longitudinal study of a non-profit organisation redefining their core purpose and attempting to design a customer-centric business model.
Resumo:
This paper presents findings of an embedded action research project within a small to medium sized enterprise (SME). Through the implementation of design-led innovation processes, this research aims to identify the changes experienced in the participating company during a shift in the perspective of design from a product focus towards a strategic focus. Staff interviews and a reflective journal were used as methods to collect data from a range of design interventions that were facilitated throughout the engagement. A shift in perspective of design was evident through three cultural changes within the firm. First, the perceived outcome focus of design became increasingly long-term. Second, the value of design outcomes became less directed towards current projects, and more directed towards future possibilities. Finally, the perceived tangibility of design outcomes shifted from tangible to intangible. For example, design activities which produced customer insights, rather than product features, became seen as beneficial to the firm. These three components are proposed as cultural stepping stones which describe how a company transitions from an exclusively product-focused perspective and utilisation of design towards design as a company based process. Implications of this research provide considerations for designers who are attempting to facilitate a similar transformation within a business in the future.
Resumo:
The objectives of this study were (A) to record the inner prosthesis loading during activities of daily living (ADL), (B) to present a set of variables comparing loading data, and (C) to provide an example of characterisation of two prostheses. The load was measured at 200 Hz using a multi-axial transducer mounted between the residuum and the knee of an individual with unilateral transfemoral amputation fitted with a bone-anchored prosthesis. The load was measured while using two different prostheses including a mechanically (PRO1) and a microprocessor controlled (PRO2) knee during six ADL. The characterisation of prosthesis was achieved using a set of variables split into four categories, including temporal characteristics, maximum loading, loading slopes and impulse. Approximately 360 gait cycles were analysed for each prosthesis. PRO1 showed a cadence improved by 19% and 7%, a maximum force on the long axis reduced by 11% and 19%, as well as an impulse reduced by 32% and 15% during descent of incline and stairs compared to PRO2, respectively. This work confirmed that the proposed apparatus and characterisation can reveal how changes of prosthetic components are translated into inner loading.
Resumo:
This study aimed at presenting the intra-tester reliability of the static load bearing exercises (LBEs) performed by individuals with transfemoral amputation (TFA) fitted with an osseointegrated implant to stimulate the bone remodelling process. There is a need for a better understanding of the implementation of these exercises particularly the reliability. The intra-tester reliability is discussed with a particular emphasis on inter-load prescribed, inter-axis and inter-component reliabilities as well as the effect of body weight normalisation. Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. Reliability of loading variables was assessed using intraclass correlation coefficients (ICCs) and percentage standard error of measurement values (%SEMs). The ICCs of all variables were above 0.9 and the %SEM values ranged between 0 and 87%. This study showed a high between-participants’ variance highlighting the lack of loading consistency typical of symptomatic population as well as a high reliability between the loading sessions indicating a plausible correct repetition of the LBE by the participants. However, these outcomes must be understood within the framework of the proposed experimental protocol.