349 resultados para Hot air drying

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microscopic changes occur in plant food materials during drying significantly influence the macroscopic properties and quality factors of the dried food materials. It is very critical to study microstructure to understand the underlying cellular mechanisms to improve performance of the food drying techniques. However, there is very limited research conducted on such microstructural changes of plant food material during drying. In this work, Gala apple parenchyma tissue samples were studied using a scanning electron microscope for gradual microstructural changes as affected by temperature, time and moisture content during hot air drying at two drying temperatures: 57 ℃ and 70 ℃. For fresh samples, the average cellular parameter values were; cell area: 20000 μm2, ferret diameter: 160 μm, perimeter: 600 μm, roundness: 0.76, elongation: 1.45 and compactness: 0.84. During drying, a higher degree of cell shrinkage was observed with cell wall warping and increase in intercellular space. However, no significant cell wall breakage was observed. The overall reduction of cell area, ferret diameter and perimeter were about 60%, 40% and 30%. The cell roundness and elongation showed overall increments of about 5% and the compactness remained unchanged. Throughout the drying cycle, cellular deformations were mainly influenced by the moisture content. During the initial and intermediate stages of drying, cellular deformations were also positively influenced by the drying temperature and the effect was reversed at the final stages of drying which provides clues for case hardening of the material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The drying of grapes is a more complex process compared to the dehydration of other agricultural materials due to the necessity of a pretreatment operation prior to drying. Grape drying to produce raisins is a very slow process, due to the peculiar structure of grape peel, that is covered by a waxy layer.Its removal has benn so far carried out by using several chemical pre-treatments. However, they cause heterogeneity in the waxes removal and create microscopic cracks. In this paper an abrasive pretreatment for enhancing the drying rate and preserving the grape samples is proposed. Two cultivars of grape were investigated: Regina white grape and Red Globe red grape. The drying kinetics of untreated and treated samples were studied using a convective oven at 50 C. Fruit quality parameters such as sugar and organic acid contents, shrinkage, texture, peel damage (i.e. by SEM analysis) and rehydration capacity were studied to evaluate the effectiveness of abrasive pretreatment on raisins. Abrasive pretreatment contributed to reduce drying time and rehydration time. The treated and untreated dried grapes were significantly different (p<0.05) in sugar and in tartaric acid content. On the contrary, no significant differences (p<0.05) in malic and citric acids in texture peoperties between untreated and treated samples were observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is widely recognised that exposure to air pollutants affect pulmonary and lung dysfunction as well as a range of neurological and vascular disorders. The rapid increase of worldwide carbon emissions continues to compromise environmental sustainability whilst contributing to premature death. Moreover, the harms caused by air pollution have a more pernicious reach, such as being the major source of climate change and ‘natural disasters’, which reportedly kills millions of people each year (World Health Organization, 2012). The opening quotations tell a story of the UK government's complacency towards the devastation of toxic and contaminating air emissions. The above headlines greeted the British public earlier this year after its government was taken to the Court of Appeal for an appalling air pollution record that continues to cause the premature deaths of 30,000 British people each year at a health cost estimated at £20 billion per annum. This combined with pending legal proceedings against the UK government for air pollution violations by the European Commission, point to a Cameron government that prioritises hot air and profit margins over human lives. The UK's legal air pollution regimes are an industry dominated process that relies on negotiation and partnership between regulators and polluters. The entire model seeks to assist business compliance rather than punish corporate offenders. There is no language of ‘crime’ in relation to UK air pollution violations but rather a discourse of ‘exceedence’ (Walters, 2010). It is a regulatory system not premised on the ‘polluter pay’ principle but instead the ‘polluter profit’ principle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Across time, companies have increasingly made public commitments to sustainable development and to reducing their impacts on climate change. Management remuneration plans (MRPs) are a key mechanism to motivate managers to achieve corporate goals. We review the MRPs negotiated with key management personnel in a sample of large Australian carbon-intensive companies. Our results show that, as in past decades, the companies in our sample have MRPs in place that continue to fixate on financial performance. We argue that this provides evidence of a disconnection, or ‘decoupling’, between the sustainability-related rhetoric of the sample companies, and their ‘real’ organisational practices and priorities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Hot air ballooning incidents are relatively rare, however, when they do occur they are likely to result in a fatality or serious injury. Human error is commonly attributed as the cause of hot air ballooning incidents; however, error in itself is not an explanation for safety failures. This research aims to identify, and establish the relative importance of factors contributing towards hot air ballooning incidents. Methods: Twenty-two Australian Ballooning Federation (ABF) incident reports were thematically coded using a bottom up approach to identify causal factors. Subsequently, 69 balloonists (mean 19.51 years’ experience) participated in a survey to identify additional causal factors and rate (out of seven) the perceived frequency and potential impact to ballooning operations of each of the previously identified causal factors. Perceived associated risk was calculated by multiplying mean perceived frequency and impact ratings. Results: Incident report coding identified 54 causal factors within nine higher level areas: Attributes, Crew resource management, Equipment, Errors, Instructors, Organisational, Physical Environment, Regulatory body and Violations. Overall, ‘weather’, ‘inexperience’ and ‘poor/inappropriate decisions’ were rated as having greatest perceived associated risk. Discussion: Although errors were nominated as a prominent cause of hot air ballooning incidents, physical environment and personal attributes are also particularly important for safe hot air ballooning operations. In identifying a range of causal factors the areas of weakness surrounding ballooning operations have been defined; it is hoped that targeted safety and training strategies can now be put into place removing these contributing factors and reducing the chance of pilot error.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hot air ballooning incidents are relatively rare; however, they have a high potential to be fatal. In order to inform appropriate safety interventions it is first necessary to understand the causal factors which lead to incidents and near-misses, which requires a formal incident report database. The Australian Balloon Federation (ABF) advocates the reporting of recreational hot air ballooning incidents, by reporting directly to the ABF safety officer or by completing an online incident report form. The objective of this paper is to understand how widely used the reporting system is and whether there are any perceived barriers to reporting. Sixty-nine balloonists participated in an online survey about their experience of incident reporting. Survey respondents were mostly male (11 female), experienced balloonists (mean years’ experience ballooning 19.51y with a SD 11.19). Sixty respondents (87%) held a pilot license. The majority (82.6%) of respondents were aware of the ABF incident reporting system. Over half (62.3%) had been involved in a ballooning incident or near-miss in Australia. However, 40% of those who had an incident or near-miss did not report it to the ABF and only 15.9% of all those surveyed had used the online incident report form. There was some disagreement regarding when it was appropriate to report an incident or near miss. Some respondents felt an incident or near miss should only be reported if it resulted in injury or damage, while others said near-misses should also be reported. The most frequent barriers identified were: a lack of understanding of when to report to the ABF; trivializing of incidents; and concerns about the system itself Steps should be taken to increase understanding of the system purpose and long term benefits. Specifically, reporting near-misses should be encouraged. This study is significant because it is the first to examine reporting practices in non-motorised recreational aviation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three particular geometrical shapes of parallelepiped, cylindrical and spheres were selected from potatoes (aspect ratio = 1:1, 2:1, 3:1), cut beans (length:diameter = 1:1, 2:1, 3:1) and peas respectively. The density variation of food particulates was studied in a batch fluidised bed dryer connected to a heat pump dehumidifier system. Apparent density and bulk density were evaluated with non-dimensional moisture at three different drying temperatures of 30, 40 and 50 o C. Relative humidity of hot air was kept at 15% in all drying temperatures. Several empirical relationships were developed for the determination of changes in densities with the moisture content. Simple mathematical models were obtained to relate apparent density and bulk density with moisture content.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A coupled SPH-DEM based two-dimensional (2-D) micro-scale single cell model is developed to predict basic cell-level shrinkage effects of apple parenchyma cells during air drying. In this newly developed drying model, Smoothed Particle Hydrodynamics (SPH) is used to model the low Reynolds Number fluid motions of the cell protoplasm, and a Discrete Element Method (DEM) is employed to simulate the polymer-like cell wall. Simulations results reasonably agree with published experimental drying results on cellular shrinkage properties such as cellular area, diameter and perimeter. These preliminary results indicate that the model is effective for the modelling and simulation of apple parenchyma cells during air drying.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To examine the relationship between contact lens (CL) case contamination and various potential predictive factors. METHODS: 74 subjects were fitted with lotrafilcon B (CIBA Vision) CLs on a daily wear basis for 1 month. Subjects were randomly assigned one of two polyhexamethylene biguanide (PHMB) preserved disinfecting solutions with the corresponding regular lens case. Clinical evaluations were conducted at lens delivery and after 1 month, when cases were collected for microbial culture. A CL care non-compliance score was determined through administration of a questionnaire and the volume of solution used was calculated for each subject. Data was examined using backward stepwise binary logistic regression. RESULTS: 68% of cases were contaminated. 35% were moderately or heavily contaminated and 36% contained gram-negative bacteria. Case contamination was significantly associated with subjective dryness symptoms (OR 4.22, CI 1.37–13.01) (P<0.05). There was no association between contamination and subject age, ethnicity, gender, average wearing time, amount of solution used, non-compliance score, CL power and subjective redness (P>0.05). The effect of lens care system on case contamination approached significance (P=0.07). Failure to rinse the case with disinfecting solution following CL insertion (OR 2.51, CI 0.52–12.09) and not air drying the case (OR 2.31, CI 0.39–13.35) were positively correlated with contamination; however, did not reach statistical significance. CONCLUSIONS: Our results suggest that case contamination may influence subjective comfort. It is difficult to predict the development of case contamination from a variety of clinical factors. The efficacy of CL solutions, bacterial resistance to disinfection and biofilm formation are likely to play a role. Further evaluation of these factors will improve our understanding of the development of case contamination and its clinical impact.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article follows on from our previous article in Aeronotes Volume 37 No.2 "Prepare and prevent, don't repair and repent: Causal factors of hot air ballooning incidents". While nearly every balloon flight ends safely, with every flight comes the opportunity for an accident. The ABF maintains an incident reporting database containing information on all the accidents and near misses that are reported to them. The goal of the database is to provide a formal way for ABF members to share accident or near miss experiences and prevent future occurrences. We recently analysed the causal factors involved in the incident reports collected by the ABF. Twenty-two incident reports were analysed and 54 causal factors were identified that were reported to play a role in hot air ballooning accidents. While many factors were identified, the findings of this study were limited by the small number of incident reports available from the ABF reporting system...

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Air pollution levels were monitored continuously over a period of 4 weeks at four sampling sites along a busy urban corridor in Brisbane. The selected sites were representative of industrial and residential types of urban environment affected by vehicular traffic emissions. The concentration levels of submicrometer particle number, PM2.5, PM10, CO, and NOx were measured 5-10 meters from the road. Meteorological parameters and traffic flow rates were also monitored. The data were analysed in terms of the relationship between monitored pollutants and existing ambient air quality standards. The results indicate that the concentration levels of all pollutants exceeded the ambient air background levels, in certain cases by up to an order of magnitude. While the 24-hr average concentration levels did not exceed the standard, estimates for the annual averages were close to, or even higher than the annual standard levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In paper has been to investigate the morphological patterns and kinetics of PDMS spreading on silicon wafer using combination of techniques like ellipsometry, atomic force microscope (AFM), scanning electron microscope (SEM) and optical microscopy. A macroscopic silicone oil drops as well as PDMS water based emulsions were studied after deposition on a flat surface of silicon wafer in air, water and vacuum. our own measurements using an imaging ellipsometer, which also clearly shows the presence of a precursor film. The diffusion constant of this film, measured with a 60 000 cS PDMS sample spreading on a hydrophilic silicon wafer, is Df = 1.4  10-11 m2/s. Regardless of their size, density and method of deposition, droplets on both types of wafer (hydrophilic and hydrophobic) flatten out over a period of many hours, up to 3 days. During this process neighbouring droplets may coalesce, but there is strong evidence that some of the PDMS from the droplets migrates into a thin, continuous film that covers the surface in between droplets. The thin film appears to be ubiquitous if there has been any deposition of PDMS. However, this statement needs further verification. One question is whether the film forms immediately after forced drying, or whether in some or all cases it only forms by spreading from isolated droplets as they slowly flatten out.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study demonstrates the possibility of using an absorption chiller to produce chilled water for air conditioning, and at the same time recover the rejected heat producing domestic hot water. The absorption chiller considered for this application has been sized to suit a standard household and uses a solution of ammonia and water running on hot water at a temperature ranging from 80 - 120°C produced by thermal solar panels. The system consists of five main components: generator, rectifier, condenser, evaporator and absorber, and is divided in two sections at two different pressures. The section at higher pressure includes the generator, rectifier and condenser whereas the section at lower pressure includes the evaporator and the absorber. Heat in this type of system is usually rejected to the environment from the condenser, rectifier and absorber through a cooling tower or air cooler exchanger. In this paper we describe how to recover this heat to create domestic hot water by providing a quantitative evaluation of the amount of energy recovered by the proposed system, if used in the Australian region.