185 resultados para Higher order aberrations
em Queensland University of Technology - ePrints Archive
Resumo:
Purpose: Poor image quality in the peripheral field may lead to myopia. Most studies measuring the higher order aberrations in the periphery have been restricted to the horizontal visual field. The purpose of this study was to measure higher order monochromatic aberrations across the central 42º horizontal x 32º vertical visual fields in myopes and emmetropes. ---------- Methods: We recruited 5 young emmetropes with spherical equivalent refractions +0.17 ± 0.45D and 5 young myopes with spherical equivalent refractions -3.9 ± 2.09D. Measurements were taken with a modified COAS-HD Hartmann-Shack aberrometer (Wavefront Sciences Inc). Measurements were taken while the subjects looked at 38 points arranged in a 7 x 6 matrix (excluding four corner points) through a beam splitter held between the instrument and the eye. A combination of the instrument’s software and our own software was used to estimate OSA Zernike coefficients for 5mm pupil diameter at 555nm for each point. The software took into account the elliptical shape of the off-axis pupil. Nasal and superior fields were taken to have positive x and y signs, respectively. ---------- Results: The total higher order RMS (HORMS) was similar on-axis for emmetropes (0.16 ± 0.02 μm) and myopes (0.17 ± 0.02 μm). There was no common pattern for HORMS for emmetropes across the visual field where as 4 out of 5 myopes showed a linear increase in HORMS in all directions away from the minimum. For all subjects, vertical and horizontal comas showed linear changes across the visual field. The mean rate of change of vertical coma across the vertical meridian was significantly lower (p = 0.008) for emmetropes (-0.005 ± 0.002 μm/deg) than for myopes (-0.013 ± 0.004 μm/deg). The mean rate of change of horizontal coma across the horizontal meridian was lower (p = 0.07) for emmetropes (-0.006 ± 0.003 μm/deg) than myopes (-0.011 ± 0.004 μm/deg). ---------- Conclusion: We have found differences in patterns of higher order aberrations across the visual fields of emmetropes and myopes, with myopes showing the greater rates of change of horizontal and vertical coma.
Resumo:
Purpose: We compared subjective blur limits for defocus and the higher-order aberrations of coma, trefoil, and spherical aberration. ---------- Methods: Spherical aberration was presented in both Zernike and Seidel forms. Black letter targets (0.1, 0.35, and 0.6 logMAR) on white backgrounds were blurred using an adaptive optics system for six subjects under cycloplegia with 5 mm artificial pupils. Three blur criteria of just noticeable, just troublesome, and just objectionable were used.---------- Results: When expressed as wave aberration coefficients, the just noticeable blur limits for coma and trefoil were similar to those for defocus, whereas the just noticeable limits for Zernike spherical aberration and Seidel spherical aberration (the latter given as an “rms equivalent”) were considerably smaller and larger, respectively, than defocus limits.---------- Conclusions: Blur limits increased more quickly for the higher order aberrations than for defocus as the criterion changed from just noticeable to just troublesome and then to just objectionable.
Resumo:
This study compared the corneal and total higher order aberrations between the fellow eyes in monocular amblyopia. Nineteen amblyopic subjects (8 refractive and 11 strabismic) (mean age 30 ± 11 years) were recruited. A range of biometric and optical measurements were collected from the amblyopic and non-amblyopic eye including; axial length, corneal topography and total higher order aberrations. For a sub-group of eleven non-presbyopic subjects (6 refractive and 5 strabismic amblyopes, mean age 29 ± 10 years) total higher order aberrations were also measured during accommodation (2.5 D stimuli). Amblyopic eyes were significantly shorter and more hyperopic compared to non-amblyopic eyes and the interocular difference in axial length correlated with both the magnitude of anisometropia and amblyopia (both p < 0.01). Significant differences in higher order aberrations were observed between fellow eyes, which varied with the type of amblyopia. Refractive amblyopes displayed higher levels of 4th order corneal aberrations C(4, 0)(spherical aberration), C(4, 2)(secondary astigmatism 90°) and C(4, −2)(secondary astigmatism along 45°) in the amblyopic eye compared to the non-amblyopic eye. Strabismic amblyopes exhibited significantly higher levels of C(3, 3)(trefoil) in the amblyopic eye for both corneal and total higher order aberrations. During accommodation, the amblyopic eye displayed a significantly greater lag of accommodation compared to the non-amblyopic eye, while the changes in higher order aberrations were similar in magnitude between fellow eyes. Asymmetric visual experience during development appears to be associated with asymmetries in higher order aberrations, in some cases proportional to the magnitude of anisometropia and dependent upon the amblyogenic factor.
Resumo:
Purpose: To use a large wavefront database of a clinical population to investigate relationships between refractions and higher order aberrations and between aberrations of right and left eyes. Methods: Third and fourth-order aberration coefficients and higher-order root-mean-squared aberrations (HO RMS), scaled to a pupil size of 4.5 mm diameter, were analysed in a population of about 24,000 patients from Carl Zeiss Vision's European wavefront database. Correlations were determined between the aberrations and the variables of refraction, near addition and cylinder. Results: Most aberration coefficients were significantly dependent upon these variables, but the proportions of aberrations that could be explained by these factors were less than 2% except for spherical aberration (12%), horizontal coma (9%) and HO RMS (7%). Near addition was the major contributor for horizontal coma (8.5% out of 9.5%) and spherical equivalent was the major contributor for spherical aberration (7.7% out of 11.6%). Interocular correlations were highly significant for all aberration coefficients, varying between 0.16 and 0.81. Anisometropia was a variable of significance for three aberrations (vertical coma, secondary astigmatism and tetrafoil), but little importance can be placed on this because of the small proportions of aberrations that can be explained by refraction (all less than 1.0 %). Conclusions: Most third- and fourth-order aberration coefficients were significantly dependent upon spherical equivalent, near addition and cylinder, but only horizontal coma (9%) and spherical aberration (12%) showed dependencies of greater than 2%. Interocular correlations were highly significant for all aberration coefficients, but anisometropia had little influence on aberration coefficients.
Resumo:
Purpose/aim Myopia incidence is increasing around the world. Myopisation is considered to be caused by a variety of factors. One consideration is whether higher-order aberrations (HOA) influence myopisation. More knowledge of optics in anisometropic eyes might give further insight into the development of refractive error. Materials and methods To analyse the possible influence of HOA on refractive error development, we compared HOA between anisometropes and isometropes. We analysed HOA up to the 4th order for both eyes of 20 anisometropes (mean age: 43 ± 17 years) and 20 isometropes (mean age: 33 ±17 years). HOA were measured with the Shack-Hartman i.Profiler (Carl Zeiss, Germany) and were recalculated for a 4 mm pupil. Mean spherical equivalent (MSE) was based on the subjective refraction. Anisometropia was defined as ≥1D interocular difference in MSE. The mean absolute differences between right and left eyes in spherical equivalent were 0.28 ± 0.21 D in the isometropic group and 2.81 ± 2.04 D in the anisometropic group. Interocular differences in HOA were compared with the interocular difference in MSE using correlations. Results For isometropes oblique trefoil, vertical coma, horizontal coma and spherical aberration showed significant correlations between the two eyes. In anisometropes all analysed higher-order aberrations correlated significantly between the two eyes except oblique secondary astigmatism and secondary astigmatism. When analysing anisometropes and isometropes separately, no significant correlations were found between interocular differences of higher-order aberrations and MSE. For isometropes and anisometropes combined, tetrafoil correlated significantly with MSE in left eyes. Conclusions The present study could not show that interocular differences of higher-order aberrations increase with increasing interocular difference in MSE.
Resumo:
Background Wavefront-guided Laser-assisted in situ keratomileusis (LASIK) is a widespread and effective surgical treatment for myopia and astigmatic correction but whether it induces higher-order aberrations remains controversial. The study was designed to evaluate the changes in higher-order aberrations after wavefront-guided ablation with IntraLase femtosecond laser in moderate to high astigmatism. Methods Twenty-three eyes of 15 patients with moderate to high astigmatism (mean cylinder, −3.22 ± 0.59 dioptres) aged between 19 and 35 years (mean age, 25.6 ± 4.9 years) were included in this prospective study. Subjects with cylinder ≥ 1.5 and ≤2.75 D were classified as moderate astigmatism while high astigmatism was ≥3.00 D. All patients underwent a femtosecond laser–enabled (150-kHz IntraLase iFS; Abbott Medical Optics Inc) wavefront-guided ablation. Uncorrected (UDVA), corrected (CDVA) distance visual acuity in logMAR, keratometry, central corneal thickness (CCT) and higher-order aberrations (HOAs) over a 6 mm pupil, were assessed before and 6 months, postoperatively. The relationship between postoperative change in HOA and preoperative mean spherical equivalent refraction, mean astigmatism, and postoperative CCT were tested. Results At the last follow-up, the mean UDVA was increased (P < 0.0001) but CDVA remained unchanged (P = 0.48) and no eyes lost ≥2 lines of CDVA. Mean spherical equivalent refraction was reduced (P < 0.0001) and was within ±0.50 D range in 61 % of eyes. The average corneal curvature was flatter by 4 D and CCT was reduced by 83 μm (P < 0.0001, for all), postoperatively. Coma aberrations remained unchanged (P = 0.07) while the change in trefoil (P = 0.047) postoperatively, was not clinically significant. The 4th order HOAs (spherical aberration and secondary astigmatism) and the HOA root mean square (RMS) increased from −0.18 ± 0.07 μm, 0.04 ± 0.03 μm and 0.47 ± 0.11 μm, preoperatively, to 0.33 ± 0.19 μm (P = 0.004), 0.21 ± 0.09 μm (P < 0.0001) and 0.77 ± 0.27 μm (P < 0.0001), six months postoperatively. The change in spherical aberration after the procedure increased with an increase in the degree of preoperative myopia. Conclusions Wavefront-guided IntraLASIK offers a safe and effective option for vision and visual function improvement in astigmatism. Although, reduction of HOA is possible in a few eyes, spherical-like aberrations are increased in majority of the treated eyes.
Resumo:
The effectiveness of higher-order spectral (HOS) phase features in speaker recognition is investigated by comparison with Mel Cepstral features on the same speech data. HOS phase features retain phase information from the Fourier spectrum unlikeMel–frequency Cepstral coefficients (MFCC). Gaussian mixture models are constructed from Mel– Cepstral features and HOS features, respectively, for the same data from various speakers in the Switchboard telephone Speech Corpus. Feature clusters, model parameters and classification performance are analyzed. HOS phase features on their own provide a correct identification rate of about 97% on the chosen subset of the corpus. This is the same level of accuracy as provided by MFCCs. Cluster plots and model parameters are compared to show that HOS phase features can provide complementary information to better discriminate between speakers.
Resumo:
We investigate the potential for the third-order aberrations coma and trefoil to provide a signed cue to accommodation. It is first demonstrated theoretically (with some assumptions) that the point spread function is insensitive to the sign of spherical defocus in the presence of odd-order aberrations. In an experimental investigation, the accommodation response to a sinusoidal change in vergence (1–3 D, 0.2 Hz) of a monochromatic stimulus was obtained with a dynamic infrared optometer. Measurements were obtained in 10 young visually normal individuals with and without custom contact lenses that induced low and high values of r.m.s. trefoil (0.25, 1.03 μm) and coma (0.34, 0.94 μm). Despite variation between subjects, we did not find any statistically significant increase or decrease in the accommodative gain for low levels of trefoil and coma, although effects approached or reached significance for the high levels of trefoil and coma. Theoretical and experimental results indicate that the presence of Zernike third-order aberrations on the eye does not seem to play a crucial role in the dynamics of the accommodation response.
Resumo:
The middle years of schooling has emerged as an important focus in Australian education. Student disengagement and alienation, the negative effects of non-completion of the senior years of schooling and underachievement have raised concerns about the quality of education during the middle years. For many schools, reshaping the middle years has involved incorporating Information and Communication Technologies (ICT) to motivate students. However, simultaneously there is a need to ensure that programs are academically rigorous. There is little doubt that there are potential benefits to integrating ICT into programs for middle years’ students. However, little is known about how middle years’ teachers perceive higher order thinking, which is a component of academic rigour. This paper investigates the question of What are teachers’ perceptions of higher order thinking in an ICT environment? The study is underpinned by socio-cultural theory which is based on the belief that learning occurs through social interaction and that individuals are shaped by the social and cultural tools and instruments they engage with. This investigation used a collective case study design. Two methods were used for data collection. These methods are semi-structured interviews with individual teachers and a class and a focus group discussion with teachers. Findings indicate that teachers hold various perceptions of higher order thinking that lead to productive approaches to integrating ICT in middle years’ classrooms. The paper highlights that there may be a continuum of perceptions of higher order thinking with ICT. This continuum may inform professional developers who are guiding and supporting teachers to integrate ICT into middle years’ classrooms.