324 resultados para Heat loss coefficient
em Queensland University of Technology - ePrints Archive
Resumo:
To reduce the natural convection heat loss from enclosures many researchers used convection suppression devices in the past. In this study a single baffle is used under the top tip to investigate numerically the natural convection heat loss in an attic shaped enclosure which is a cost effective approach. The case considered here is one inclined wall of the enclosure is uniformly heated while the other inclined wall is uniformly cooled with adiabatic bottom wall. The finite volume method has been used to discretize the governing equations, with the QUICK scheme approximating the advection term. The diffusion terms are discretized using central-differencing with second order accuracy. A wide range of governing parameters are studied (Rayleigh number, aspect ratio, baffle length etc.). It is observed that the heat transfer due to natural convection in the enclosure reduces when the baffle length is increased. Effects of other parameters on heat transfer and flow field are described in this study.
Resumo:
Concepts used in this chapter include: Thermoregulation:- Thermoregulation refers to the body’s sophisticated, multi-system regulation of core body temperature. This hierarchical system extends from highly thermo-sensitive neurons in the preoptic region of the brain proximate to the rostral hypothalamus, down to the brain stem and spinal cord. Coupled with receptors in the skin and spine, both central and peripheral information on body temperature is integrated to inform and activate the homeostatic mechanisms which maintain our core temperature at 37oC.1 Body heat is lost through the skin, via respiration and excretions. The skin is perhaps the most important organ in regulating heat loss. Hyporthermia:- Hypothermia is defined as core body temperature less than 350C and is the result of imbalance between the body’s heat production and heat loss mechanisms. Hypothermia may be accidental, or induced for clinical benefit i.e: neurological protection (therapeutic hypothermia). External environmental conditions are the most common cause of accidental hypothermia, but not the only causes of hypothermia in humans. Other causes include metabolic imbalance; trauma; neurological and infectious disease; and exposure to toxins such as organophosphates. Therapeutic Hypothermia:- In some circumstances, hypothermia can be induced to protect neurological functioning as a result of the associated decrease in cerebral metabolism and energy consumption. Reduction in the extent of degenerative processes associated with periods of ischaemia such as excitotoxic cascade; apoptotic and necrotic cell death; microglial activation; oxidative stress and inflammation associated with ischaemia are averted or minimised.2 Mild hypothermia is the only effective treatment confirmed clinically for improving the neurological outcomes of patient’s comatose following cardiac arrest.3
Resumo:
Background Women undergoing Cesarean Section (CS) are vulnerable to the adverse effects associated with perioperative core temperature drop, in part due to the tendency for CS to be performed under neuraxial anesthesia, blood and fluid loss, and vasodilation. Inadvertent perioperative hypothermia (IPH) is a common condition that affects patients undergoing surgery of all specialties and is detrimental to all age groups, including neonates. Previous systematic reviews on IPH prevention largely focus on either adult or all ages populations, and have mainly overlooked pregnant or CS patients as a distinct group. Not all recommendations made by systematic reviews targeting all adult patients may be transferable to CS patients. Alternative, effective methods for preventing or managing hypothermia in this group would be valuable. Objectives To synthesize the best available evidence in relation to preventing and/or treating hypothermia in mothers after CS surgery. Types of participants Adult patients over the age of 18 years, of any ethnic background, with or without co-morbidities, undergoing any mode of anesthesia for any type of CS (emergency or planned) at healthcare facilities who have received interventions to limit or manage perioperative core heat loss were included. Types of intervention(s) Active or passive warming methods versus usual care or placebo, that aim to limit or manage core heat loss as applied to women undergoing CS were included. Types of studies Randomized controlled trials (RCTs) that met the inclusion criteria, with reduction of perioperative hypothermia a primary or secondary outcome were considered. Types of outcomes Primary outcome: maternal core temperature measured during the preoperative, intraoperative and postoperative phases of care Secondary outcomes: newborn core temperature at birth, umbilical pH obtained immediately after birth, Apgar scores, length of Post Anesthetic Care Unit (PACU) stay, maternal thermal comfort. Search strategy A comprehensive search was undertaken of the following databases from their inception until May 2012: ProQuest, Web of Science, Scopus, Dissertation and Theses PQDT (via ProQuest), Current Contents, CENTRAL, Mednar, OpenGrey, Clinical Trials. There were no language restrictions. Methodological quality Retrieved papers were assessed for methodological quality by two independent reviewers prior to inclusion using JBI software. Disagreements were resolved via consultation with the third reviewer. An assessment of quality of the included papers was also made in relation to five key quality factors. Data collection Two independent reviewers extracted data from the included papers using a previously piloted customized data extraction tool. Results 12 studies with a combined total of 719 participants were included. Three broad intervention groups were identified; intravenous (IV) fluid warming, warming devices, leg wrapping. IV fluid warming, whether administered intraoperatively or preoperatively, was found to be effective at maintaining maternal (but not neonatal) temperature and preventing shivering, but does not improve thermal comfort. The effectiveness of IV fluid warming on Apgar scores and umbilical pH remains unclear. Warming devices, including forced air warming and under body carbon polymer mattresses, were effective at preventing hypothermia and reduced shivering, however were most effective if applied preoperatively. The effectiveness of warming devices to improve thermal comfort remains unclear. Preoperative forced air warming appears to aid maintenance of neonatal temperature, while intraoperative forced air warming does not. Forced air warming was not effective at improving Apgar scores and the effects for umbilical pH remain unclear. Conclusions Intravenous fluid warming, by any method, improves maternal temperature and reduces shivering for women undergoing CS. Preoperative body warming devices also improve maternal temperature, in addition to reducing shivering.
Resumo:
A purified commercial double-walled carbon nanotube (DWCNT) sample was investigated by transmission electron microscopy (TEM), thermogravimetry (TG), and Raman spectroscopy. Moreover, the heat capacity of the DWCNT sample was determined by temperature-modulated differential scanning calorimetry in the range of temperature between -50 and 290 °C. The main thermo-oxidation characterized by TG occurred at 474 °C with the loss of 90 wt% of the sample. Thermo-oxidation of the sample was also investigated by high-resolution TG, which indicated that a fraction rich in carbon nanotube represents more than 80 wt% of the material. Other carbonaceous fractions rich in amorphous coating and graphitic particles were identified by the deconvolution procedure applied to the derivative of TG curve. Complementary structural data were provided by TEM and Raman studies. The information obtained allows the optimization of composites based on this nanomaterial with reliable characteristics.
Resumo:
The climatic conditions of tropical and subtropical regions within Australia present, at times, extreme risk of physical activity induced heat illness. Many administrators and teachers in school settings are aware of the general risks of heat related illness. In the absence of reliable information applied at the local level, there is a risk that inappropriate decisions may be made concerning school events that incorporate opportunities to be physically active. Such events may be prematurely cancelled resulting in the loss of necessary time for physical activity. Under high or extremely high risk conditions however, the absence of appropriate modifications or continuation could place the health of students, staff and other parties at risk. School staff and other key stakeholders should understand the mechanisms of escalating risk and be supported to undertake action to reduce the level of risk through appropriate policies, procedures, resources and action plans.
Resumo:
The aim of the research program was to evaluate the heat strain, hydration status, and heat illness symptoms experienced by surface mine workers. An initial investigation involved 91 surface miners completing a heat stress questionnaire; assessing the work environment, hydration practices, and heat illness symptom experience. The key findings included 1) more than 80 % of workers experienced at least one symptom of heat illness over a 12 month period; and 2) the risk of moderate symptoms of heat illness increased with the severity of dehydration. These findings highlight a health and safety concern for surface miners, as experiencing symptoms of heat illness is an indication that the physiological systems of the body may be struggling to meet the demands of thermoregulation. To illuminate these findings a field investigation to monitor the heat strain and hydration status of surface miners was proposed. Two preliminary studies were conducted to ensure accurate and reliable data collection techniques. Firstly, a study was undertaken to determine a calibration procedure to ensure the accuracy of core body temperature measurement via an ingestible sensor. A water bath was heated to several temperatures between 23 . 51 ¢ªC, allowing for comparison of the temperature recorded by the sensors and a traceable thermometer. A positive systematic bias was observed and indicated a need for calibration. It was concluded that a linear regression should be developed for each sensor prior to ingestion, allowing for a correction to be applied to the raw data. Secondly, hydration status was to be assessed through urine specific gravity measurement. It was foreseeable that practical limitations on mine sites would delay the time between urine collection and analysis. A study was undertaken to assess the reliability of urine analysis over time. Measurement of urine specific gravity was found to be reliable up to 24 hours post urine collection and was suitable to be used in the field study. Twenty-nine surface miners (14 drillers [winter] and 15 blast crew [summer]) were monitored during a normal work shift. Core body temperature was recorded continuously. Average mean core body temperature was 37.5 and 37.4 ¢ªC for blast crew and drillers, with average maximum body temperatures of 38.0 and 37.9 ¢ªC respectively. The highest body temperature recorded was 38.4 ¢ªC. Urine samples were collected at each void for specific gravity measurement. The average mean urine specific gravity was 1.024 and 1.021 for blast crew and drillers respectively. The Heat Illness Symptoms Index was used to evaluate the experience of heat illness symptoms on shift. Over 70 % of drillers and over 80 % of blast crew reported at least one symptom. It was concluded that 1) heat strain remained within the recommended limits for acclimatised workers; and 2) the majority of workers were dehydrated before commencing their shift, and tend to remain dehydrated for the duration. Dehydration was identified as the primary issue for surface miners working in the heat. Therefore continued study focused on investigating a novel approach to monitoring hydration status. The final aim of this research program was to investigate the influence dehydration has on intraocular pressure (IOP); and subsequently, whether IOP could provide a novel indicator of hydration status. Seven males completed 90 minutes of walking in both a cool and hot climate with fluid restriction. Hydration variables and intraocular pressure were measured at baseline and at 30 minute intervals. Participants became dehydrated during the trial in the heat but maintained hydration status in the cool. Intraocular pressure progressively declined in the trial in the heat but remained relatively stable when hydration was maintained. A significant relationship was observed between intraocular pressure and both body mass loss and plasma osmolality. This evidence suggests that intraocular pressure is influenced by changes in hydration status. Further research is required to determine if intraocular pressure could be utilised as an indirect indicator of hydration status.
Resumo:
This study examined physiological and performance effects of pre-cooling on medium-fast bowling in the heat. Ten, medium-fast bowlers completed two randomised trials involving either cooling (mixed-methods) or control (no cooling) interventions before a 6-over bowling spell in 31.9±2.1°C and 63.5±9.3% relative humidity. Measures included bowling performance (ball speed, accuracy and run-up speeds), physical characteristics (global positioning system monitoring and counter-movement jump height), physiological (heart rate, core temperature, skin temperature and sweat loss), biochemical (serum concentrations of damage, stress and inflammation) and perceptual variables (perceived exertion and thermal sensation). Mean ball speed (114.5±7.1 vs. 114.1±7.2 km · h−1; P = 0.63; d = 0.09), accuracy (43.1±10.6 vs. 44.2±12.5 AU; P = 0.76; d = 0.14) and total run-up speed (19.1±4.1 vs. 19.3±3.8 km · h−1; P = 0.66; d = 0.06) did not differ between pre-cooling and control respectively; however 20-m sprint speed between overs was 5.9±7.3% greater at Over 4 after pre-cooling (P = 0.03; d = 0.75). Pre-cooling reduced skin temperature after the intervention period (P = 0.006; d = 2.28), core temperature and pre-over heart rates throughout (P = 0.01−0.04; d = 0.96−1.74) and sweat loss by 0.4±0.3 kg (P = 0.01; d = 0.34). Mean rating of perceived exertion and thermal sensation were lower during pre-cooling trials (P = 0.004−0.03; d = 0.77−3.13). Despite no observed improvement in bowling performance, pre-cooling maintained between-over sprint speeds and blunted physiological and perceptual demands to ease the thermoregulatory demands of medium-fast bowling in hot conditions.
Resumo:
This article presents the results on the diagnostics and numerical modeling of low-frequency (∼460 KHz) inductively coupled plasmas generated in a cylindrical metal chamber by an external flat spiral coil. Experimental data on the electron number densities and temperatures, electron energy distribution functions, and optical emission intensities of the abundant plasma species in low/intermediate pressure argon discharges are included. The spatial profiles of the plasma density, electron temperature, and excited argon species are computed, for different rf powers and working gas pressures, using the two-dimensional fluid approach. The model allows one to achieve a reasonable agreement between the computed and experimental data. The effect of the neutral gas temperature on the plasma parameters is also investigated. It is shown that neutral gas heating (at rf powers≥0.55kW) is one of the key factors that control the electron number density and temperature. The dependence of the average rf power loss, per electron-ion pair created, on the working gas pressure shows that the electron heat flux to the walls appears to be a critical factor in the total power loss in the discharge.
Resumo:
Bushfires are regular occurrences in the Australian landscape which can, under adverse weather conditions, give rise to losses of life, property, infrastructure, environmental and cultural values. Where property loss is involved, historical surveys of house losses have focussed on ember, radiant heat and flame contact as key bushfire attack mechanisms. Although often noted, little work has been done to quantify the impact of fire generated or fire enhanced wind and pyro-convective events on house loss and to improve construction practice within Australia. It is well known that strong winds are always associated with bushfire events. It is less well known, although increasingly shown through anecdotal evidence, that bushfires are not a passive companion of wind, but indeed they interact with winds and can together cause significant damages to exposed buildings and ecological structures. Previous studies have revealed the effects of wind, fire and structure interactions with the result of increased pressure coefficient distributions on the windward side of a building downstream of a fire front. This paper presents a further analysis of the result in relations to the relevant standards and fire weather conditions. A review of wind code and bushfire code was conducted. Based on the result of the current study, the authors believe it is necessary to consider wind as an attack mechanism in bushfire events. The results of the study will also have implications on bushfire emergency management, design of emergency shelters, perception of danger, emergency evacuation and on risk assessment.
Resumo:
A solar assisted heat pump is used for different applications, such as, water heating, drying and air conditioning. The unglazed evaporator-collector enables to absorb both solar energy and ambient energy due to low operating temperature. Three different systems are described: solar assisted heat pump system for hot water using an unglazed evaporator collector; solar assisted heat pump for hot water and drying, where evaporator collector and air collector are used; an integrated solar heat pump system making use of solar and ambient energy, and air-con waste heat. Unlike conventional collector, evaporator collector was found to have higher efficiency, 80% to 90%, and the coefficient of performance attained a value as high as 8.0. The integrated system leads to a reduction of global warming, as it uses solar energy, ambient energy and air-con waste heat.
Resumo:
The solar-assisted heat pump (SAHP) desalination, based on the Rankin cycle, operates in low temperature and utilizes both solar and ambient energy. An experimental SAHP desalination system has been constructed at the National University of Singapore, Singapore. The system consisted of two main sections: an SAHP and a water distillation section. Experiments were carried out under the different meteorological condition of Singapore and results showed that the system had a performance ratio close to 1.3. The heat pump has a coefficient of performance of about 8, with solar collector efficiencies of 80% and 60% for evaporator and liquid collectors, respectively. Economic analysis showed that at a production rate of 900 L/day and an evaporator collector area of around 70m2 will have a payback period of about 3.5 years.
Resumo:
Desalination is considered one of the most suitable areas for the utilization of solar energy, as there are many places in the world where abundant supply of solar energy is available and also there is a great demand for fresh water. An integrated solar heat pump desalination system has been developed at the National University of Singapore. The system also offers the opportunity of water heating and drying utilizing solar, ambient energy and waste heat from air conditioning system, which is conventionally dumped into the environment causing global warming. Desalination is carried out by making use of a single effect of Multi-Effect Distillation (MED) system. Within the desalination chamber, both fl ashing and evaporation of saline water take place. The maximum Coefficient of Performance (COP) of the heat pump system was around 5.8. In the integrated system, the maximum fresh water production rate was 9.6 l h−1 and a Performance Ratio (PR) of 1.2. For only desalination, the system has the potential to produce a maximum of 30 l h−1 of fresh water.
Resumo:
In view of the growing global demand for energy and concern expressed for environmental degradation, a clean and "free" energy source, such as solar energy, has been receiving greater attention in recent years for various applications using different techniques. The Direct Expansion Solar Assisted Heat Pump (DX-SAHP) principle is one of the most promising techniques as it makes use of both solar and ambient energy. As the system has capability to function at low temperatures, it has the potential to operate at night in the tropics. The system utilizes multi-effect distillation (MED) principle for the conversion of seawater to fresh water. An experimental setup of the DX-SAHP desalination system has been built at the Department of Mechanical Engineering, National University of Singapore (NUS). This system uses two types of flat-plate solar collectors. One is called evaporator-collector, where no glazing is used, and the efficiency varies between 80 and 90%. The other type of collector is single-glazed, where the maximum efficiency is about 60%, and it is used for feed water heating. For the heat pump cycle, refrigerant R134a is used. The present study provides a comprehensive analyses and performance evaluation of this system under different operating and meteorological conditions of Singapore. The Coefficient of Performance (COP) of the heat pump system reached a maximum value of 10. For a single effect of desalination, the system shows a Performance Ratio (PR) of around 1.3.
Resumo:
Numerical study has been performed in this study to investigate the turbulent convection heat transfer on a rectangular plate mounted over a flat surface. Thermal and fluid dynamic performances of extended surfaces having various types of lateral perforations with square, circular, triangular and hexagonal cross sections are investigated. RANS (Reynolds averaged Navier–Stokes) based modified k–ω turbulence model is used to calculate the fluid flow and heat transfer parameters. Numerical results are compared with the results of previously published experimental data and obtained results are in reasonable agreement. Flow and heat transfer parameters are presented for Reynolds numbers from 2000 to 5000 based on the fin thickness.
Resumo:
This paper investigates a pilot desalination system which consists of a direct expansion solar assisted heat pump (DXSAHP) coupled to a single-effect evaporator unit. The working fluid used is R134a and distillate is obtained via falling film evaporation and flashing in the unit. Experiments have been conducted in both day and night meteorological conditions in Singapore and the effects of solar irradiation and compressor speed have been studied against the system performance. From the experiments, the Performance Ratio (PR) obtained ranges from 0.43 to 0.88, the average Coefficient of Performance (COP) was 8 and the highest distillate production recorded was 1.38 kg/h