74 resultados para Giunzioni, Incollaggi, Pin, Collar, Interferenza
em Queensland University of Technology - ePrints Archive
Resumo:
The Katz and Kahn (1978) motivational framework is an open system management theory that underscores the importance of self-regulation while stressing the significance of using continuous feedback to adapt in a rapidly changing environment. This study aims to examine Katz and Kahn’s prepositions that the implementation of a system of rule compliance, external rewards, and internalized motivation can decrease employee turnover, increase quantitative and qualitative standards of performance, and enhance cooperation and creativeness. The results among 233 Chinese employees (96.6% response rate) indicated partial support for Katz and Kahn’s motivational framework. The implication for improving the Chinese workforce, in particular blue-collar occupations, is discussed.
Resumo:
During nutrition intervention programs, some form of dietary assessment is usually necessary. This dietary assessment can be for: initial screening; development of appropriate programs and activities; or, evaluation. Established methods of dietary assessment are not always practical, nor cost effective in such interventions, therefore an abbreviated dietary assessment tool is needed. The Queensland Nutrition Project developed such a tool for male Blue Collar Workers, the Food Behaviour Questionnaire, consisting of 27 food behaviour related questions. This tool has been validated in a sample of 23 men, through full dietary assessment obtained via food frequency questionnaires and 24 hour dietary recalls. Those questions which correlated poorly with the full dietary assessment were deleted from the tool. In all, 13 questions was all that was required to distinguish between high and low dietary intakes of particular nutrients. Three questions when combined had correlations with refined sugar between 0.617 and 0.730 (p<0.005); four questions when combined had correlations with dietary fibre as percentage of energy of 0.45 (p<0.05); five questions when combined had a correlation with total fat of 0.499 (p<0.05); and, 4 questions when combined had a correlation with saturated fat of between 0.451 and 0.589 (p<0.05). A significant correlation could not be found for food behaviour questions with respect to dietary sodium. Correlations for fat as a function of energy could not be found.
Resumo:
As a contribution to literature drawing together green criminology and studies of organised and corporate crime, this paper provides a case study of crimes and public health harms linked to the Naples garbage disposal crisis. The context is the inability of modern consumer society to cope with the problem of mass production of waste. In turn this leads to opportunities for both legal and criminal entrepreneurs to offer services that promise but fail to ‘dispose’ of the problem. The analysis draws upon environmental law and classic studies of organised crime.
Resumo:
In 2010, Vincent Ruggiero and Nigel South coined the term ‘dirty collar crime’ to define corporate entrepreneurs that monopolise waste disposal companies and profit from illegal environmental activities. This paper explores the ways in which ‘the environment’ has become big business for organised criminal enterprises. It draws on original fieldwork conducted in Italy and examines the exploits of the ‘eco mafia’. It concludes that the fluidity associated with term ‘environment’ and its cavalier usage in political and public discourse creates ambivalence for regulation and protection. Whilst trade continues to assert an international priority within the landscapes of global economics and fiscal prosperity; organized environmental crime takes advantage of growing markets. As a result, movements of environmental activism emerge as the new front in the surveillance, regulation and prosecution of organised environmental crime. Such voices must continue to be central to future green criminological perspectives that seek environmental, ecological and species justice.
Resumo:
Purpose: The aim of this study was to identify the transitional employment aspirations and training and development needs of older and younger workers at risk of early retirement due to limited education and/or employment in blue collar occupations. Design/ Methodology/ Approach: A computer based methodology was used to evaluate the demographic effects of gender, education level and occupation group on aspirations pertaining to transitional employment and training and development in a sample of over 1000 Local Government employees. Findings: Older blue collar, secondary school educated and younger workers were less interested in transitional employment than older workers with higher levels of education or from white collar backgrounds. The early retirement risk factors of blue collar work and secondary school education had a more limited effect on perceived training and development needs for older workers. However for younger workers, these risk factors provided the impetus to undertake training to move into less physically demanding or more challenging roles as their careers progressed. Practical Implications: Via the identification of education level and occupation types groups’ transitional employment aspirations and perceptions of preparatory training and development within younger and older cohorts, long term strategies to develop and retain staff may be formulated. Originality/ Value: Past studies of transitional employment have rarely included younger workers or older workers at risk of early retirement. Preparatory training and development for transitional employment roles has not been considered in the literature.
Resumo:
In conventional fabrication of ceramic separation membranes, the particulate sols are applied onto porous supports. Major structural deficiencies under this approach are pin-holes and cracks, and the dramatic losses of flux when pore sizes are reduced to enhance selectivity. We have overcome these structural deficiencies by constructing hierarchically structured separation layer on a porous substrate using lager titanate nanofibers and smaller boehmite nanofibers. This yields a radical change in membrane texture. The resulting membranes effectively filter out species larger than 60 nm at flow rates orders of magnitude greater than conventional membranes. This reveals a new direction in membrane fabrication.
Resumo:
Computer aided joint replacement surgery has become very popular during recent years and is being done in increasing numbers all over the world. The accuracy of the system depends to a major extent, on accurate registration and immobility of the tracker attachment devices to the bone. This study was designed to asses the forces needed to displace the tracker attachment devices in the bone simulators. Bone simulators were used to maintain the uniformity of the bone structure during the study. The fixation devices tested were 3mm diameter self drilling, self tapping threaded pin, 4mm diameter self tapping cortical threaded pin, 5mm diameter self tapping cancellous threaded pin and a triplanar fixation device ‘ortholock’ used with three 3mm pins. All the devices were tested for pull out, translational and rotational forces in unicortical and bicortical fixation modes. Also tested was the normal bang strength and forces generated by leaning on the devices. The forces required to produce translation increased with the increasing diameter of the pins. These were 105N, 185N, and 225N for the unicortical fixations and 130N, 200N, 225N for the bicortical fixations for 3mm, 4mm and 5mm diameter pins respectively. The forces required to pull out the pins were 1475N, 1650N, 2050N for the unicortical, 1020N, 3044N and 3042N for the bicortical fixated 3mm, 4mm and 5mm diameter pins. The ortholock translational and pull out strength was tested to 900N and 920N respectively and still it did not fail. Rotatory forces required to displace the tracker on pins was to the magnitude of 30N before failure. The ortholock device had rotational forces applied up to 135N and still did not fail. The manual leaning forces and the sudden bang forces generated were of the magnitude of 210N and 150N respectively. The strength of the fixation pins increases with increasing diameter from three to five mm for the translational forces. There is no significant difference in pull out forces of four mm and five mm diameter pins though it is more that the three mm diameter pins. This is because of the failure of material at that stage rather than the fixation device. The rotatory forces required to displace the tracker are very small and much less that that can be produced by the surgeon or assistants in single pins. Although the ortholock device was tested to 135N in rotation without failing, one has to be very careful not to put any forces during the operation on the tracker devices to ensure the accuracy of the procedure.
Resumo:
Biotribology, the study of lubrication, wear and friction within the body, has become a topic of high importance in recent times as we continue to encounter debilitating diseases and trauma that destroy function of the joints. A highly successful surgical procedure to replace the joint with an artificial equivalent alleviates dysfunction and pain. However, the wear of the bearing surfaces in prosthetic joints is a significant clinical problem and more patients are surviving longer than the life expectancy of the joint replacement. Revision surgery is associated with increased morbidity and mortality and has a far less successful outcome than primary joint replacement. As such, it is essential to ensure that everything possible is done to limit the rate of revision surgery. Past experience indicates that the survival rate of the implant will be influenced by many parameters, of primary importance, the material properties of the implant, the composition of the synovial fluid and the method of lubrication. In prosthetic joints, effective boundary lubrication is known to take place. The interaction of the boundary lubricant and the bearing material is of utmost importance. The identity of the vital active ingredient within synovial fluid (SF) to which we owe the near frictionless performance of our articulating joints has been the quest of researchers for many years. Once identified, tribo tests can determine what materials and more importantly what surfaces this fraction of SF can function most optimally with. Surface-Active Phospholipids (SAPL) have been implicated as the body’s natural load bearing lubricant. Studies in this thesis are the first to fully characterise the adsorbed SAPL detected on the surface of retrieved prostheses and the first to verify the presence of SAPL on knee prostheses. Rinsings from the bearing surfaces of both hip and knee prostheses removed from revision operations were analysed using High Performance Liquid Chromatography (HPLC) to determine the presence and profile of SAPL. Several common prosthetic materials along with a novel biomaterial were investigated to determine their tribological interaction with various SAPLs. A pin-on-flat tribometer was used to make comparative friction measurements between the various tribo-pairs. A novel material, Pyrolytic Carbon (PyC) was screened as a potential candidate as a load bearing prosthetic material. Friction measurements were also performed on explanted prostheses. SAPL was detected on all retrieved implant bearing surfaces. As a result of the study eight different species of phosphatidylcholines were identified. The relative concentrations of each species were also determined indicating that the unsaturated species are dominant. Initial tribo tests employed a saturated phosphatidylcholine (SPC) and the subsequent tests adopted the addition of the newly identified major constituents of SAPL, unsaturated phosphatidylcholine (USPC), as the test lubricant. All tribo tests showed a dramatic reduction in friction when synthetic SAPL was used as the lubricant under boundary lubrication conditions. Some tribopairs showed more of an affinity to SAPL than others. PyC performed superior to the other prosthetic materials. Friction measurements with explanted prostheses verified the presence and performance of SAPL. SAPL, in particular phosphatidylcholine, plays an essential role in the lubrication of prosthetic joints. Of particular interest was the ability of SAPLs to reduce friction and ultimately wear of the bearing materials. The identification and knowledge of the lubricating constituents of SF is invaluable for not only the future development of artificial joints but also in developing effective cures for several disease processes where lubrication may play a role. The tribological interaction of the various tribo-pairs and SAPL is extremely favourable in the context of reducing friction at the bearing interface. PyC is highly recommended as a future candidate material for use in load bearing prosthetic joints considering its impressive tribological performance.
Resumo:
Ceramic membranes are of particular interest in many industrial processes due to their ability to function under extreme conditions while maintaining their chemical and thermal stability. Major structural deficiencies under conventional fabrication approach are pin-holes and cracks, and the dramatic losses of flux when pore sizes are reduced to enhance selectivity. We overcome these structural deficiencies by constructing hierarchically structured separation layer on a porous substrate using larger titanate nanofibres and smaller boehmite nanofibres. This yields a radical change in membrane texture. The differences in the porous supports have no substantial influences on the texture of resulting membranes. The membranes with top layer of nanofibres coated on different porous supports by spin-coating method have similar size of the filtration pores, which is in a range of 10–100 nm. These membranes are able to effectively filter out species larger than 60 nm at flow rates orders of magnitude greater than conventional membranes. The retention can attain more than 95%, while maintaining a high flux rate about 900 L m-2 h. The calcination after spin-coating creates solid linkages between the fibres and between fibres and substrate, in addition to convert boehmite into -alumina nanofibres. This reveals a new direction in membrane fabrication.
Resumo:
The ‘particle size effect’ and its manifestation in abrasion still attracts considerable debate as to its origins and the ranking of its likely causes. Experiments have been conducted to study the important contribution that the formation of wear debris can have on the progression of wear. The experiments consist of unlubricated (dry) pin-on-disk tests with silicon carbide coated paper of varying particle size, with different pin material, diameter and loads. It has been observed that the influence of debris formation on wear rate is more pronounced for fine abrasives and soft-wearing materials. Consequently, it is proposed that the particle size effect can be explained in terms of geometrical scaling and the evolution of third-body effects with diminishing particle diameter.
Resumo:
The purpose of the current article was to explore perceptions of transitional employment and training and development amongst blue collar workers employed in technical, trade, operations or physical and labour-intensive occupations within the local government system.
Resumo:
We describe a moving virtual fence algorithm for herding cows. Each animal in the herd is given a smart collar consisting of a GPS, PDA, wireless networking and a sound amplifier. Using the GPS, the animal's location can be verified relative to the fence boundary. When approaching the perimeter, the animal is presented with a sound stimulus whose effect is to move away. We have developed the virtual fence control algorithm for moving a herd. We present simulation results and data from experiments with 8 cows equipped with smart collars.
Resumo:
This paper presents an automated system for 3D assembly of tissue engineering (TE) scaffolds made from biocompatible microscopic building blocks with relatively large fabrication error. It focuses on the pin-into-hole force control developed for this demanding microassembly task. A beam-like gripper with integrated force sensing at a 3 mN resolution with a 500 mN measuring range is designed, and is used to implement an admittance force-controlled insertion using commercial precision stages. Visual-based alignment followed by an insertion is complemented by a haptic exploration strategy using force and position information. The system demonstrates fully automated construction of TE scaffolds with 50 microparts whose dimension error is larger than 5%.