78 resultados para EPITHERMAL NEUTRON-SPECTRUM

em Queensland University of Technology - ePrints Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electron Volt Spectrometer (eVS) is an inverse geometry filter difference spectrometer that has been optimised to measure the single atom properties of condensed matter systems using a technique known as Neutron Compton Scattering (NCS) or Deep Inelastic Neutron Scattering (DINS). The spectrometer utilises the high flux of epithermal neutrons that are produced by the ISIS neutron spallation source enabling the direct measurement of atomic momentum distributions and ground state kinetic energies. In this paper the procedure that is used to calibrate the spectrometer is described. This includes details of the method used to determine detector positions and neutron flight path lengths as well as the determination of the instrument resolution. Examples of measurements on 3 different samples are shown, ZrH2, 4He and Sn which show the self-consistency of the calibration procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electron Volt Spectrometer (eVS) is an inverse geometry filter difference spectrometer that has been optimised to measure the single atom properties of condensed matter systems using a technique known as Neutron Compton Scattering (NCS) or Deep Inelastic Neutron Scattering (DINS). The spectrometer utilises the high flux of epithermal neutrons that are produced by the ISIS neutron spallation source enabling the direct measurement of atomic momentum distributions and ground state kinetic energies. In this paper the procedure that is used to calibrate the spectrometer is described. This includes details of the method used to determine detector positions and neutron flight path lengths as well as the determination of the instrument resolution. Examples of measurements on 3 different samples are shown, ZrH2, 4He and Sn which show the self-consistency of the calibration procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Raman spectra at 77 K of the hydroxyl stretching of kaolinite were obtained along the three axes perpendicular to the crystal faces. Raman bands were observed at 3616, 3658 and 3677 cm−1 together with a distinct band observed at 3691 cm−1 and a broad profile between 3695 and 3715 cm−1. The band at 3616 cm−1 is assigned to the inner hydroxyl. The bands at 3658 and 3677 cm−1 are attributed to the out-of-phase vibrations of the inner surface hydroxyls. The Raman spectra of the in-phase vibrations of the inner-surface hydroxyl-stretching region are described in terms of transverse and longitudinal optic splitting. The band at 3691 cm−1 is assigned to the transverse optic and the broad profile to the longitudinal optic mode. This splitting remained even at liquid nitrogen temperature. The transverse optic vibration may be curve resolved into two or three bands, which are attributed to different types of hydroxyl groups in the kaolinite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total cross sections for neutron scattering from nuclei, with energies ranging from 10 to 600 MeV and from many nuclei spanning the mass range 6Li to 238U, have been analyzed using a simple, three-parameter, functional form. The calculated cross sections are compared with results obtained by using microscopic (g-folding) optical potentials as well as with experimental data. The functional form reproduces those total cross sections very well. When allowance is made for Ramsauer-like effects in the scattering, the parameters of the functional form required vary smoothly with energy and target mass. They too can be represented by functions of energy and mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To report on the design, significance and potential impacts of the first documented human clinical trial assessing the anxiolytic and thymoleptic efficacy of an aqueous monoextract of Piper methysticum (kava). The significance of the qualitative element of our clinical trial is also explored. The Kava Anxiety Depression Spectrum Study (KADSS) is a 3-week placebocontrolled, double-blind, cross-over trial involving 60 adult participants (18—65) with elevated stable anxiety and varying levels of depressive symptoms. Aims: The aims of KADSS are: (1) to determine whether an aqueous standardised extract of kava is effective for the treatment of anxiety; (2) to assess the effects of kava on differing levels of depression; and (3) to explore participants’ experience of taking kava via qualitative research. The study also provides preliminary assessment of the safety of an aqueous extract of kava in humans. Conclusion: If results reveal that the aqueous kava preparation exerts significant anxiolytic effects and appears safe, potentially beneficial impacts may occur. Data supporting a safe and effective kava extract may encourage a re-introduction of kava to Europe, UK and Canada. This may provide a major socioeconomic benefit to Pacific Island nations, and to sufferers of anxiety disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rationale: Piper methysticum (Kava) has been withdrawn in European, British, and Canadian markets due to concerns over hepatotoxic reactions. The WHO recently recommended research into “aqueous” extracts of Kava. Objective: The objective of this study was to conduct the first documented human clinical trial assessing the anxiolytic and antidepressant efficacy of an aqueous extract of Kava. Design and participants: The Kava Anxiety Depression Spectrum Study was a 3-week placebo-controlled, double-blind crossover trial that recruited 60 adult participants with 1 month or more of elevated generalized anxiety. Five Kava tablets per day were prescribed containing 250 mg of kavalactones/day. Results: The aqueous extract of Kava reduced participants' Hamilton Anxiety Scale score in the first controlled phase by −9.9 (CI = 7.1, 12.7) vs. −0.8 (CI = −2.7, 4.3) for placebo and in the second controlled phase by −10.3 (CI = 5.8, 14.7) vs. +3.3 (CI = −6.8, 0.2). The pooled effect of Kava vs. placebo across phases was highly significant (p < 0.0001), with a substantial effect size (d = 2.24, η² [sub]p[sub] = 0.428). Pooled analyses also revealed highly significant relative reductions in Beck Anxiety Inventory and Montgomery–Asberg Depression Rating Scale scores. The aqueous extract was found to be safe, with no serious adverse effects and no clinical hepatotoxicity. Conclusions: The aqueous Kava preparation produced significant anxiolytic and antidepressant activity and raised no safety concerns at the dose and duration studied. Kava appears equally effective in cases where anxiety is accompanied by depression. This should encourage further study and consideration of globally reintroducing aqueous rootstock extracts of Kava for the management of anxiety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mosston & Ashworth‟s Spectrum of Teaching styles was first published in 1966 and is potentially the longest surviving model of teaching within the field of physical education. Its longevity and influence is surely testament to its value and influence. Many tools have also been developed through the years based on The Spectrum of Teaching Styles. In 2005 as part of a doctoral study, this tool was developed by the author, Dr Edwards and Dr Ashworth for researchers and teachers to identify which teaching styles were being utilised from The Spectrum when teaching physical education. It could also be utilised for self-assessment of the teaching styles and individual uses, or those who work with Physical Education Teacher Education courses. The development of this tool took approximately 4 months, numerous emails and meetings. This presentation will outline this process, along with the reasons why such a tool was developed and the differences between it and others like it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spectrum sensing is considered to be one of the most important tasks in cognitive radio. Many sensing detectors have been proposed in the literature, with the common assumption that the primary user is either fully present or completely absent within the window of observation. In reality, there are scenarios where the primary user signal only occupies a fraction of the observed window. This paper aims to analyse the effect of the primary user duty cycle on spectrum sensing performance through the analysis of a few common detectors. Simulations show that the probability of detection degrades severely with reduced duty cycle regardless of the detection method. Furthermore we show that reducing the duty cycle has a greater degradation on performance than lowering the signal strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we propose a new method for utilising phase information by complementing it with traditional magnitude-only spectral subtraction speech enhancement through Complex Spectrum Subtraction (CSS). The proposed approach has the following advantages over traditional magnitude-only spectral subtraction: (a) it introduces complementary information to the enhancement algorithm; (b) it reduces the total number of algorithmic parameters, and; (c) is designed for improving clean speech magnitude spectra and is therefore suitable for both automatic speech recognition (ASR) and speech perception applications. Oracle-based ASR experiments verify this approach, showing an average of 20% relative word accuracy improvements when accurate estimates of the phase spectrum are available. Based on sinusoidal analysis and assuming stationarity between observations (which is shown to be better approximated as the frame rate is increased), this paper also proposes a novel method for acquiring the phase information called Phase Estimation via Delay Projection (PEDEP). Further oracle ASR experiments validate the potential for the proposed PEDEP technique in ideal conditions. Realistic implementation of CSS with PEDEP shows performance comparable to state of the art spectral subtraction techniques in a range of 15-20 dB signal-to-noise ratio environments. These results clearly demonstrate the potential for using phase spectra in spectral subtractive enhancement applications, and at the same time highlight the need for deriving more accurate phase estimates in a wider range of noise conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The neutron logging method has been widely used for field measurement of soil moisture content. This non-destructive method permitted the measurement of in-situ soil moisture content at various depths without the need for burying any sensor. Twenty-three sites located around regional Melbourne have been selected for long term monitoring of soil moisture content using neutron probe. Soil samples collected during the installation are used for site characterisation and neutron probe calibration purposes. A linear relationship is obtained between the corrected neutron probe reading and moisture content for both the individual and combined data from seven sites. It is observed that the liner relationship, developed using combined data, can be used for all sites with an average accuracy of about 80%. Monitoring of the variation of soil moisture content with depth in six months for two sites is presented in this paper.