2 resultados para ENDOSCOPES

em Queensland University of Technology - ePrints Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Professional prac− tice guidelines for endoscope reprocessing re− commend reprocessing endoscopes between each case and proper storage following repro− cessing after the last case of the list. There is lim− ited empirical evidence to support the efficacy of endoscope reprocessing prior to use in the first case of the day; however, internationally, many guidelines continue to recommend this practice. The aim of this study is to estimate a safe shelf life for flexible endoscopes in a high−turnover gastroenterology unit. Materials and methods: In a prospective obser− vational study, all flexible endoscopes in active service during the 3−week study period were mi− crobiologically sampled prior to reprocessing be− fore the first case of the day (n = 200). The main outcome variables were culture status, organism cultured, and shelf life. Results: Among the total number of useable samples (n = 194), the overall contamination rate was 15.5 %, with a pathogenic contamination rate of 0.5 %. Mean time between last case one day and reprocessing before the first case on the next day (that is, shelf life) was 37.62 h (SD 36.47). Median shelf life was 18.8 h (range 5.27± 165.35 h). The most frequently identified organ− ism was coagulase−negative Staphylococcus, an environmental nonpathogenic organism. Conclusions: When processed according to es− tablished guidelines, flexible endoscopes remain free from pathogenic organisms between last case and next day first case use. Significant re− ductions in the expenditure of time and resources on reprocessing endoscopes have the potential to reduce the restraints experienced by high−turnover endoscopy units and improve ser− vice delivery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Throughout history, developments in medicine have aimed to improve patient quality of life, and reduce the trauma associated with surgical treatment. Surgical access to internal organs and bodily structures has been traditionally via large incisions. Endoscopic surgery presents a technique for surgical access via small (1 Omm) incisions by utilising a scope and camera for visualisation of the operative site. Endoscopy presents enormous benefits for patients in terms of lower post operative discomfort, and reduced recovery and hospitalisation time. Since the first gall bladder extraction operation was performed in France in 1987, endoscopic surgery has been embraced by the international medical community. With the adoption of the new technique, new problems never previously encountered in open surgery, were revealed. One such problem is that the removal of large tissue specimens and organs is restricted by the small incision size. Instruments have been developed to address this problem however none of the devices provide a totally satisfactory solution. They have a number of critical weaknesses: -The size of the access incision has to be enlarged, thereby compromising the entire endoscopic approach to surgery. - The physical quality of the specimen extracted is very poor and is not suitable to conduct the necessary post operative pathological examinations. -The safety of both the patient and the physician is jeopardised. The problem of tissue and organ extraction at endoscopy is investigated and addressed. In addition to background information covering endoscopic surgery, this thesis describes the entire approach to the design problem, and the steps taken before arriving at the final solution. This thesis contributes to the body of knowledge associated with the development of endoscopic surgical instruments. A new product capable of extracting large tissue specimens and organs in endoscopy is the final outcome of the research.