28 resultados para Dressings

em Queensland University of Technology - ePrints Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Greater research utilisation in cancer nursing practice is needed, in order to provide well-informed and effective nursing care to people affected by cancer. This paper aims to report on the implementation of evidence-based practice in a tertiary cancer centre. Methods: Using a case report design, this paper reports on the use of the Collaborative Model for Evidence Based Practice (CMEBP) in an Australian tertiary cancer centre. The clinical case is the uptake of routine application of chlorhexidine-impregnated sponge dressings for preventing centrally inserted catheter-related bloodstream infections. In this case report, a number of processes that resulted in a service-wide practice change are described. Results: This model was considered a feasible method for successful research utilisation. In this case report, chlorhexidine-impregnated sponge dressings were proposed and implemented in the tertiary cancer centre with an aim of reducing the incidence of centrally inserted catheter-related bloodstream infections and potentially improving patient health outcomes. Conclusion: The CMEBP is feasible and effective for implementing clinical evidence into cancer nursing practice. Cancer nurses and health administrators need to ensure a supportive infrastructure and environment for clinical inquiry and research utilisation exists, in order to enable successful implementation of evidence-based practice in their cancer centres.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pilot study was conducted to compare four types of dressings used to treat skin tears in nursing home residents. Wounds treated with a non-occlusive dressing healed more quickly than those dressed with occlusive dressings. The results suggest that ease of use and product wastage are important considerations when treating skin tears. The pilot study also highlights the need for further research into skin tear management and the need for ongoing education for nurses regarding skin integrity risk assessment and product information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat, Acticoat combined with Mepitel and Mepilex Ag dressings for acute, paediatric partial thickness burns. METHODS/DESIGN: Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of dressings. DISCUSSION: The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ACTRN12613000105741.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a method to test the cytotoxicity of wound dressings, ointments, creams and gels used in our Burn Centre, by placing them on a permeable Nunc Polycarbonate cell culture insert, incubated with a monolayer of cells (HaCaTs and primary human keratinocytes). METHODS: We performed two different methods to determine the relative toxicity to cells. (1) Photo visualisation: The dressings or compounds were positioned on the insert's membrane which was placed onto the monolayer tissue culture plate. After 24 h the surviving adherent cells were stained with Toluidine Blue and photos of the plates were taken. The acellular area of non-adherent dead cells which had been washed off with buffer was measured as a percentage of the total area of the plate. (2) Cell count of surviving cells: After 24 h incubation with the test material, the remaining cells were detached with trypsin, spun down and counted in a Haemocytometer with Trypan Blue, which differentiates between live and dead cells. RESULTS: Seventeen products were tested. The least cytotoxic products were Melolite, White soft Paraffin and Chlorsig1% Ointment. Some cytotoxicity was shown with Jelonet, Mepitel((R)), PolyMem((R)), DuoDerm((R)) and Xeroform. The most cytotoxic products included those which contained silver or Chlorhexidine and Paraffin Cream a moisturizer which contains the preservative Chlorocresol. CONCLUSION: This in vitro cell culture insert method allows testing of agents without direct cell contact. It is easy and quick to perform, and should help the clinician to determine the relative cytotoxicity of various dressings and the optimal dressing for each individual wound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND This study compared the effects of three silver dressing combinations on small to medium size acute partial thickness burns in children, focusing on re-epithelialization time, pain and distress during dressing changes. METHOD Children (0-15 years) with clean, ≤ 10% total body surface area (TBSA) partial thickness burns who met the inclusion criteria were included in the study. Children received either (1) Acticoat™; (2) Acticoat™ with Mepitel™; or (3) Mepilex Ag™ dressings. Measures of burn re-epithelialization, pain, and distress were recorded at dressing changes every 3-5 days until full re-epithelialization occurred. RESULTS One hundred and three children were recruited with 96 children included for analysis. No infections were detected for the course of the study. When adjusted for burn depth, Acticoat™ significantly increased the expected days to full re-epithelialization by 40% (IRR = 1.40; 95% CI: 1.14-1.73, p < 0.01) and Acticoat™ with Mepitel™ significantly increased the expected days to full re-epithelialization by 33% (IRR = 1.33; 95% CI: 1.08-1.63, p ≤ 0.01) when compared to Mepilex Ag™. Expected FLACC scores in the Mepilex Ag™ group were 32% lower at dressing removal (p = 0.01) and 37% lower at new dressing application (p = 0.04); and scores in the Acticoat™ with Mepitel™ group were 23% lower at dressing removal (p = 0.04) and 40% lower at new dressing application (p < 0.01), in comparison to the Acticoat™ group. Expected Visual Analog Scale-Pain (VAS-P) scores were 25% lower in the Mepilex Ag™ group at dressing removal (p = 0.04) and 34% lower in the Acticoat™ with Mepitel™ group (p = 0.02) at new dressing application in comparison to the Acticoat™ group. There was no significant difference between the Mepilex Ag™ and the Acticoat™ with Mepitel™ groups at all timepoints and with any pain measure. CONCLUSION Mepilex Ag™ is an effective silver dressing, in terms of accelerated wound re-epithelialization time (compared to Acticoat™ and Acticoat™ with Mepitel™) and decreased pain during dressing changes (compared to Acticoat™), for clean, < 10% TBSA partial thickness burns in children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel burn wound hydrogel dressing has been previously developed which is composed of 2-acrylamido-2-methylpropane sulfonic acid sodium salt with silver nanoparticles. This study compared the antimicrobial efficacy of this novel dressing to two commercially available silver dressings; Acticoat™ and PolyMem Silver(®). Three different antimicrobial tests were used: disc diffusion, broth culture, and the Live/Dead(®) Baclight™ bacterial viability assay. Burn wound pathogens (P. aeruginosa, MSSA, A. baumannii and C. albicans) and antibiotic resistant strains (MRSA and VRE) were tested. All three antimicrobial tests indicated that Acticoat™ was the most effective antimicrobial agent, with inhibition zone lengths of 13.9-18.4mm. It reduced the microbial inocula below the limit of detection (10(2)CFU/ml) and reduced viability by 99% within 4h. PolyMem Silver(®) had no zone of inhibition for most tested micro-organisms, and it also showed poor antimicrobial activity in the broth culture and Live/Dead(®) Baclight™ assays. Alarmingly, it appeared to promote the growth of VRE. The silver hydrogel reduced most of the tested microbial inocula below the detection limit and decreased bacterial viability by 94-99% after 24h exposure. These results support the possibility of using this novel silver hydrogel as a burn wound dressing in the future

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Successful repair of wounds and tissues remains a major healthcare and biomedical challenge in the 21st Century. In particular, chronic wounds often lead to loss of functional ability, increased pain and decreased quality of life, and can be a burden on carers and health-system resources. Advanced healing therapies employing biological dressings, skin substitutes, growth factor-based therapies and synthetic a cellular matrices, all of which aim to correct irregular and dysfunctional cellular pathways present in chronic wounds, are becoming more popular. This review focuses on recent advances in biologically inspired devices for would healing and includes a commentary on the challenges facing the regulatory governance of such products.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of ultra-thin films as dressings for cutaneous wounds could prove advantageous in terms of better conformity to wound topography and improved vapour transmission. For this purpose, ultra-thin poly(epsilon-caprolactone) (PCL) films of 5-15 microm thickness were fabricated via a biaxial stretching technique. To evaluate their in vivo biocompatibility and feasibility as an external wound dressing, PCL films were applied over full and partial-thickness wounds in rat and pig models. Different groups of PCL films were used: untreated, NaOH-treated, untreated with fibrin, NaOH-treated with perforations, and NaOH-treated with fibrin and S-nitrosoglutathione. Wounds with no external dressings were used as controls. Wound contraction rate, histology and biomechanical analyses were carried out. Wounds re-epithelialized completely at a comparable rate. Formation of a neo-dermal layer and re-epithelialization were observed in all the wounds. A lower level of fibrosis was observed when PCL films were used, compared to the control wounds. Ultimate tensile strength of the regenerated tissue in rats reached 50-60% of that in native rat skin. Results indicated that biaxially-stretched PCL films did not induce inflammatory reactions when used in vivo as a wound dressing and supported the normal wound healing process in full and partial-thickness wounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To provide an overview and a critical appraisal of systematic reviews (SRs) of published interventions for the prevention/management of radiation dermatitis. Methods and Materials: We searched Medline, CINAHL, Embase, and the Cochrane Library. We also manually searched through individual reference lists of potentially eligible articles and a number of key journals in the topic area. Two authors screened all potential articles and included eligible SRs. Two authors critically appraised and extracted key findings from the included reviews using AMSTAR (the measurement tool for “assessment of multiple systematic reviews”). Results: Of 1837 potential titles, 6 SRs were included. A number of interventions have been reported to be potentially beneficial for managing radiation dermatitis. Interventions evaluated in these reviews included skin care advice, steroidal/nonsteroidal topical agents, systemic therapies, modes of radiation delivery, and dressings. However, all the included SRs reported that there is insufficient evidence supporting any single effective intervention. The methodological quality of the included studies varied, and methodological shortfalls in these reviews might create biases to the overall results or recommendations for clinical practice. Conclusions: An up-to-date high-quality SR in the prevention/management of radiation dermatitis is needed to guide practice and direction for future research. We recommend that clinicians or guideline developers critically evaluate the information of SRs in their decision making.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wound healing involves a complex series of biochemical events and has traditionally been managed with 'low tech' dressings and bandages. The concept that diagnostic and theranostic sensors can complement wound management is rapidly growing in popularity as there is tremendous potential to apply this technology to both acute and chronic wounds. Benefits in sensing the wound environment include reduction of hospitalization time, prevention of amputations and better understanding of the processes which impair healing. This review discusses the state-of-the-art in detection of markers associated with wound healing and infection, utilizing devices imbedded within dressings or as point-of-care techniques to allow for continual or rapid wound assessment and monitoring. Approaches include using biological or chemical sensors of wound exudates and volatiles to directly or indirectly detect bacteria, monitor pH, temperature, oxygen and enzymes. Spectroscopic and imaging techniques are also reviewed as advanced wound monitoring techniques. The review concludes with a discussion of the limitations of and future directions for this field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Despite the technologic advances, radiation dermatitis is still a prevalent and distressing symptom in patients with cancer undergoing radiotherapy. Systematic reviews (SRs) are regarded as level I evidence providing direction for clinical practice and guidelines. This overview aims to provide a critical appraisal of SRs published on interventions for the prevention/management of radiation dermatitis. Methodology: We searched the following electronic databases: MEDLINE, CINAHL, EMBASE, and the Cochrane Library (up to Feb 2012). We also hand-searched reference lists of potentially eligible articles and a number of key journals in the area. Two authors screened all potential articles and included eligible SRs. Two authors critically appraised and extracted key findings from the included reviews using the “A Measurement Tool to Assess Systematic Reviews” (AMSTAR). Results: Of 1837 potential titles, six SRs were included. A number of interventions have been reported to be potentially beneficial for managing radiation dermatitis. Interventions evaluated in these reviews included skin care advice, steroidal/non-steroidal topical agents, systematic therapies, modes of radiation delivery, and dressings. However, all the included SRs reported that there is insufficient evidence supporting any single effective intervention. The methodological quality of the included studies varied, and methodological shortfalls in these reviews may create biases to the overall results or recommendations for clinical practice. Conclusions and implications: An up-to-date high quality SR in preventing/managing radiation dermatitis is needed to guide practice and direction for future research. Clinicians or guideline developers are recommended to critically evaluate the information of SRs in their decision making.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose The use of intravascular devices is associated with a number of potential complications. Despite a number of evidence-based clinical guidelines in this area, there continues to be nursing practice discrepancies. This study aims to examine nursing practice in a cancer care setting to identify nursing practice and areas for improvement respective to best available evidence. Methods A point prevalence survey was undertaken in a tertiary cancer care centre in Queensland, Australia. On a randomly selected day, four nurses assessed intravascular device related nursing practices and collected data using a standardized survey tool. Results 58 inpatients (100%) were assessed. Forty-eight (83%) had a device in situ, comprising 14 Peripheral Intravenous Catheters (29.2%), 14 Peripherally Inserted Central Catheters (29.2%), 14 Hickman catheters (29.2%) and six Port-a-Caths (12.4%). Suboptimal outcomes such as incidences of local site complications, incorrect/inadequate documentation, lack of flushing orders, and unclean/non intact dressings were observed. Conclusions This study has highlighted a number of intravascular device related nursing practice discrepancies compared with current hospital policy. Education and other implementation strategies can be applied to improve nursing practice. Following education strategies, it will be valuable to repeat this survey on a regular basis to provide feedback to nursing staff and implement strategies to improve practice. More research is required to provide evidence to clinical practice with regards to intravascular device related consumables, flushing technique and protocols.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Radiation-induced skin reaction (RISR) is a common side effect that affects the majority of cancer patients receiving radiation treatment. RISR is often characterised by swelling,redness, pigmentation, fibrosis, and ulceration, pain, warmth, burning, and itching of the skin. The aim of this systematic review was to assess the effects of interventions which aim to prevent or manage RISR in people with cancer. Methods We searched the following databases up to November 2012: Cochrane Skin Group Specialised Register, CENTRAL (2012, Issue 11), MEDLINE (from 1946), EMBASE (from 1974), PsycINFO (from 1806), CINAHL (from 1981) and LILACS (from 1982). Randomized controlled trials evaluating interventions for preventing or managing RISR in cancer patients were included. The primary outcomes were development of RISR, and levels of RISR and symptom severity. Secondary outcomes were time taken to develop erythema or dry desquamation; quality of life; time taken to heal, a number of skin reaction and symptom severity measures; cost, participant satisfaction; ease of use and adverse effects. Where appropriate, we pooled results of randomized controlled trials using mean differences (MD) or odd ratios (OR) with 95% confidence intervals (CI). Results Forty-seven studies were included in this review. These evaluated six types of interventions (oral systemic medications; skin care practices; steroidal topical therapies; non-steroidal topical therapies; dressings and other). Findings from two meta-analyses demonstrated significant benefits of oral Wobe-Mugos E for preventing RISR (OR 0.13 (95% CI 0.05 to 0.38)) and limiting the maximal level of RISR (MD −0.92 (95% CI −1.36 to −0.48)). Another meta-analysis reported that wearing deodorant does not influence the development of RISR (OR 0.80 (95% CI 0.47 to 1.37)). Conclusions Despite the high number of trials in this area, there is limited good, comparative research that provides definitive results suggesting the effectiveness of any single intervention for reducing RISR. More research is required to demonstrate the usefulness of a wide range of products that are being used for reducing RISR. Future efforts for reducing RISR severity should focus on promising interventions, such as Wobe-Mugos E and oral zinc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We wished to determine whether changing our centre's practice of using Acticoat instead of Silvazine as our first-line burns dressing provided a better standard of care in terms of efficacy, cost and ease of use. A retrospective cohort study was performed examining 328 Silvazine treated patients from January 2000 to June 2001 and 241 Acticoat treated patients from July 2002 to July 2003. During those periods the respective dressings were used exclusively. There was no significant difference in age, %BSA and mechanism of burn between the groups. In the Silvazine group, 25.6% of children required grafting compared to 15.4% in the Acticoat group (p=0.001). When patients requiring grafting were excluded, the time taken for re-epithelialisation in the Acticoat group (14.9 days) was significantly less than that for the Silvazine group (18.3 days), p=0.047. There were more wounds requiring long term scar management in the Silvazine group (32.6%) compared to the Acticoat group (29.5%), however this was not significant. There was only one positive blood culture in each group, indicating that both Silvazine and Acticoat are potent antimicrobial agents. The use of Acticoat as our primary burns dressing has dramatically changed our clinical practice. Inpatients are now only 18% of the total admissions, with the vast majority of patients treated on an outpatient basis. In terms of cost, Acticoat was demonstrated to be less expensive over the treatment period than Silvazine . We have concluded that Acticoat is a safe, cost-effective, efficacious dressing that reduces the time for re-epithelialisation and the requirement for grafting and long term scar management, compared to Silvazine.