116 resultados para Discomfort glare

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Glare indices have yet to be extensively tested in daylit open plan offices, as such there is no effective method to predict discomfort glare within these spaces. This study into discomfort glare in open plan green buildings targeted full-time employees, working under their everyday lighting conditions. Three green buildings in Brisbane were used for data collection, two were Green Star accredited and the other contained innovative daylighting strategies. Data were collected on full-time employees, mostly aged between 30 and 50 years, who broadly reflect the demographics of the wider working population in Australia. It was discovered 36 of the 64 respondents experienced discomfort from both electric and daylight sources at their workspace. The study used a specially tailored post-occupancy evaluation (POE) survey to help assess discomfort glare. Luminance maps extracted from High Dynamic Range (HDR) images were used to capture the luminous environment of the occupants. These were analysed using participant data and the program Evalglare. The physical results indicated no correlation with other developed glare metrics for daylight within these open plan green buildings, including the recently developed Daylight Glare Probability (DGP) Index. The strong influence of vertical illuminance, Ev in the DGP precludes the mostly contrast-based glare from windows observed in this investigation from forming a significant part of this index. Furthermore, critical assessment of the survey techniques used are considered. These will provide insight for further research into discomfort glare in the endeavour to fully develop a suitable glare metric.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study presents the largest-known, investigation on discomfort glare with 493 surveys collected from five green buildings in Brisbane, Australia. The study was conducted on full-time employees, working under their everyday lighting conditions, all of whom had no affiliation with the research institution. The survey consisted of a specially tailored questionnaire to assess potential factors relating to discomfort glare. Luminance maps extracted from high dynamic range (HDR) images were used to capture the luminous environment of the occupants. Occupants who experienced glare on their monitor and/or electric glare were excluded from analysis leaving 419 available surveys. Occupants were more sensitive to glare than any of the tested indices accounted for. A new index, the UGP was developed to take into account the scope of results in the investigation. The index is based on a linear transformation of the UGR to calculate a probability of disturbed persons. However all glare indices had some correlation to discomfort, and statistically there was no difference between the DGI, UGR and CGI. The UGP broadly reflects the demographics of the working population in Australia and the new index is applicable to open plan green buildings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unfortunately, there is no reliable method to adequately quantify discomfort glare. One of the world's largest investigations on discomfort glare was conducted in five Green Star office buildings in Brisbane. Luminance mapping via high dynamic range images and Post Occupancy Evaluation surveys were used in the data collection. A new glare index, termed the Unified Glare Probability, was developed to predict discomfort glare within these types of office buildings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effective daylighting of multistorey commercial building interiors poses an interesting problem for designers in Australia’s tropical and subtropical context. Given that a building exterior receives adequate sun and skylight as dictated by location-specific factors such as weather, siting and external obstructions; then the availability of daylight throughout its interior is dependant on certain building characteristics: the distance from a window façade (room depth), ceiling or window head height, window size and the visible transmittance of daylighting apertures. The daylighting of general stock, multistorey commercial buildings is made difficult by their design limitations with respect to some of these characteristics. The admission of daylight to these interiors is usually exclusively by vertical windows. Using conventional glazing, such windows can only admit sun and skylight to a depth of approximately 2 times the window height. This penetration depth is typically much less than the depth of the office interiors, so that core areas of these buildings receive little or no daylight. This issue is particularly relevant where deep, open plan office layouts prevail. The resulting interior daylight pattern is a relatively narrow perimeter zone bathed in (sometimes too intense) light, contrasted with a poorly daylit core zone. The broad luminance range this may present to a building occupant’s visual field can be a source of discomfort glare. Furthermore, the need in most tropical and subtropical regions to restrict solar heat gains to building interiors for much of the year has resulted in the widespread use of heavily tinted or reflective glazing on commercial building façades. This strategy reduces the amount of solar radiation admitted to the interior, thereby decreasing daylight levels proportionately throughout. However this technique does little to improve the way light is distributed throughout the office space. Where clear skies dominate weather conditions, at different times of day or year direct sunlight may pass unobstructed through vertical windows causing disability or discomfort glare for building occupants and as such, its admission to an interior must be appropriately controlled. Any daylighting system to be applied to multistorey commercial buildings must consider these design obstacles, and attempt to improve the distribution of daylight throughout these deep, sidelit office spaces without causing glare conditions. The research described in this thesis delineates first the design optimisation and then the actual prototyping and manufacture process of a daylighting device to be applied to such multistorey buildings in tropical and subtropical environments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

High Dynamic Range (HDR) imaging was used to collect luminance information at workstations in 2 open-plan office buildings in Queensland, Australia: one lit by skylights, vertical windows and electric light, and another by skylights and electric light. This paper compares illuminance and luminance data collected in these offices with occupant feedback to evaluate these open-plan environments based on available and emerging metrics for visual comfort and glare. This study highlights issues of daylighting quality and measurement specific to open plan spaces. The results demonstrate that overhead glare is a serious threat to user acceptance of skylights, and that electric and daylight integration and controls have a major impact on the perception of daylighting quality. With regards to measurement of visual comfort it was found that the Daylight Glare Probability (DGP) gave poor agreement with occupant reports of discomfort glare in open-plan spaces with skylights, and the CIE Glare Index (CGI) gave the best agreement. Horizontal and vertical illuminances gave no indication of visual comfort in these spaces.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

High luminance contrast between windows and surrounding surfaces could cause discomfort glare, which could reduce office workers’ productivity. It might also increase energy usage of buildings due to occupants’ interventions in lighting conditions to improve indoor visual quality. It is presumed that increasing the luminance of the areas surrounding the windows using a supplementary system, such Light Emitting Diodes (LEDs), could reduce discomfort glare. This paper reports on the results of a pilot study in a conventional office in Brisbane, Australia. The outcomes of this study indicated that a supplementary LED system could reduce the luminance contrast on the window wall from values in the order of 24:1 to 12:1. The results suggest that this reduction could significantly reduce discomfort glare from windows, as well as diminishing the likelihood of users’ intention to turn on the ceiling lights and/ or to move the blind down.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mr Mehdi Amirkhani presented his research and case studies on improved lighting design in commercial spaces through daylight control and innovative lighting placement. This technical meeting was organised by IESANZ Queensland Chapter on April 7, 2016.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This study investigated the effects of experimentally induced visual impairment, headlamp glare and clothing on pedestrian visibility. Methods: 28 young adults (M=27.6±4.7 yrs) drove around a closed road circuit at night while pedestrians walked in place at the roadside. Pedestrians wore either black clothing, black clothing with a rectangular vest consisting of 1325 cm2 of retroreflective tape, or the same amount of tape positioned on the extremities in a configuration that conveyed biological motion (“biomotion”). Visual impairment was induced by goggles containing either blurring lenses, simulated cataracts, or clear lenses; visual acuity for the cataract and blurred lens conditions was matched. Drivers pressed a response pad when they first recognized that a pedestrian was present. Sixteen participants drove around the circuit in the presence of headlamp glare while twelve drove without glare. Results: Visual impairment, headlamp glare and pedestrian clothing all significantly affected drivers’ ability to recognize pedestrians (p<0.05). The simulated cataracts were more disruptive than blur, even though acuity was matched across the two manipulations. Pedestrians were recognized more often and at longer distances when they wore “biomotion” clothing than either the vest or black clothing, even in the presence of visual impairment and glare. Conclusions: Drivers’ ability to see and respond to pedestrians at night is degraded by modest visual impairments even when vision meets driver licensing requirements; glare further exacerbates these effects. Clothing that includes retroreflective tape in a biological motion configuration is relatively robust to visual impairment and glare.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been well established that highlighting the cultural attributes of a region through stories of place, local histories, and the creative arts boosts tourism income to a region. Cultural tourism also serves to promote the creative industries to visitors and residents alike and, by enhancing a region’s cultural identity, fosters new opportunities for the arts. It can therefore offer considerable potential benefit to the creative economy in Australia. However, in comparison with Europe, where cultural tourism can rely upon an established historical, artistic and literary cultural identity that stretches back to Grand Tours of the seventeenth century, in Queensland, Australia the relatively new enterprise of cultural tourism must compete with visitor expectations of sun, surf and the natural landscapes, which have become the mainstay of tourism advertising. Moreover, in Queensland, it is essential to connect vast distances, diverse communities and a variety of cultural experiences. We must also take account of the expectations of contemporary tourists, who anticipate a digitally mediated travel experience and increasingly seek to connect with local communities in authentic ways. In this paper we consider the unique considerations that must be taken into account in the Queensland context and propose approaches to developing an integrated identity that embraces both the ‘great outdoors’ and the region’s cultural attributes. We make recommendations for providing the types of digitally mediated ‘local’ experiences that cultural tourists now expect, and illustrate the design principles we propose through early, tentative approaches to smart phones, locative media and augmented reality applications for cultural tourism in the region. We conclude by proposing additional ways to formulate a digital strategy in line with the recommendations we make.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The report of this subcommittee concerns the impact of contact lenses (CLs) on the ocular surface, with a particular emphasis on CL discomfort (CLD). We define the ocular surface, its regional anatomy, and the physiological responses of each region to CL wear.